X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-117-21263

Well Details

Well ID: 37-117-21263
Loading map...
Country: United States
State: Pennsylvania
County: Tioga
Municipality: Chatham Township
Operator Name: SWEPI LP
Well Pad ID: 149297
Farm/Lease Name: SHOWALTER 822 1H
License Status:
Spud Date:
Permit Date: 2011-06-27
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.8952
Longitude: -77.391606

For data sources see[1][2][3]

Well History

Date Event
2011-06-27 New Permit Application
2011-09-06 Performed Spud Operation
2011-09-26 Drilling Completion
2012-01-08 Perforation
2012-08-16 DEVIATED

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2012-01-08 2012-01-08 4,947 2,912,031

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 AI-250 Clearwater International Gel 2-Butoxyethanol 111-76-2 40.00 0.00030000
Isopropanol 67-63-0 40.00 0.00030000
Ethoxylated Nonylphenol 13.00 0.00010000
Propargyl alcohol 107-19-7 40.00 0.00030000
Fumaric acid 110-17-8 7.00 0.00008000
15 HCl Nalco Acid Hydrochloric acid 7647-01-0 15.00 0.04
Water Shell Water/Produced Water H2O + Disolved Salts 100.00 84.40
Sand Shell Sand Quartz 14808-60-7 100.00 15.03
LEB 10X Clearwater International Enzymatic Breaker Ethylene glycol 107-21-1 60.00 0.00001000
Superflo 100 CESI Chemical Superflo 100 Citrus terpenes 94266-47-4 15.00 0.02
Isopropanol 67-63-0 15.00 0.02
StimLube W CESI Chemical Stimlube Distillates, petroleum, hydrotreated light 64742-47-8 20.00 0.00822000
AI-250 Clearwater International Acid Inhibitor
SI-112 Clearwater International Scale Inhibitor Ethylene glycol 107-21-1 40.00 0.00995000
Biocide EC 6116A Nalco Biocide Polyethylene glycol 25322-68-3 60.00 0.00664000
2,2-Dibromo-3-nitrilopropionamide 10222-01-2 30.00 0.00332000
Dibromoacetonitrile 3252-43-5 5.00 0.00055000

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2011 SWEPI LP 0.00 0 0.00 0 0.00 0
2012 SWEPI LP 238,277.43 289 0.00 0 0.00 0
2013 SWEPI LP 187,891.43 319 0.00 0 0.00 0
2014 SWEPI LP 131,074.25 218 0.00 0 0.00 0
2015 SWEPI LP 122,298.16 140 0.00 0 0.00 0
2016 SWEPI LP 116,008.16 180 0.00 0 0.00 0
2017 SWEPI LP 107,718.56 144 0.00 0 0.00 0
2018 SWEPI LP 93,983.08 149 0.00 0 0.00 0
2019 SWEPI LP 83,405.42 186 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2012 SWEPI LP Produced Fluid 10,538.22 Bbl REUSE OTHER THAN ROAD SPREADING
2012 SWEPI LP Drilling Fluid Waste 25.31 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123
2012 SWEPI LP Produced Fluid 33.33 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123
2012 SWEPI LP Fracing Fluid Waste 4,587.98 Bbl REUSE OTHER THAN ROAD SPREADING
2012 SWEPI LP Produced Fluid 37.30 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW018
2012 SWEPI LP Fracing Fluid Waste 80.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NC006
2012 SWEPI LP Fracing Fluid Waste 310.60 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW018
2012 SWEPI LP Fracing Fluid Waste 1,110.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR119
2012 SWEPI LP Fracing Fluid Waste 179.37 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123
2013 SWEPI LP Produced Fluid 166.29 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW018
2013 SWEPI LP Produced Fluid 8,922.41 Bbl REUSE OTHER THAN ROAD SPREADING
2013 SWEPI LP Produced Fluid 369.97 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR119
2013 SWEPI LP Produced Fluid 770.41 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2013 SWEPI LP Fracing Fluid Waste 168.93 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2013 SWEPI LP Fracing Fluid Waste 1,608.83 Bbl REUSE OTHER THAN ROAD SPREADING
2014 SWEPI LP Fracing Fluid Waste 91.35 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2014 SWEPI LP Produced Fluid 62.77 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW018
2014 SWEPI LP Fracing Fluid Waste 745.00 Bbl REUSE OTHER THAN ROAD SPREADING
2014 SWEPI LP Produced Fluid 2,685.28 Bbl REUSE OTHER THAN ROAD SPREADING
2014 SWEPI LP Produced Fluid 99.99 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC018
2014 SWEPI LP Produced Fluid 212.27 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC010
2015 SWEPI LP Produced Fluid 733.33 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC018
2015 SWEPI LP Produced Fluid 2,624.67 Bbl REUSE OTHER THAN ROAD SPREADING
2016 SWEPI LP Synthetic Liner Materials 1.56 Tons LANDFILL 301358
2016 SWEPI LP Produced Fluid 100.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC018
2016 SWEPI LP Produced Fluid 34.17 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC010
2016 SWEPI LP Produced Fluid 3,017.67 Bbl REUSE OTHER THAN ROAD SPREADING
2017 SWEPI LP Produced Fluid 31.71 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2017 SWEPI LP Waste Water Treatment Sludge 0.94 Tons RESIDUAL WASTE PROCESSING FACILITY WMGR123
2017 SWEPI LP Other Oil & Gas Wastes 0.09 Bbl RESIDUAL WASTE TRANSFER FACILITY 7-3115-00193
2017 SWEPI LP Produced Fluid 1,791.27 Bbl REUSE (AT WELL PAD)
2017 SWEPI LP Produced Fluid 551.31 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC022
2018 SWEPI LP Produced Fluid 116.99 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC022
2018 SWEPI LP Produced Fluid 949.98 Bbl REUSE (AT WELL PAD)
2018 SWEPI LP Produced Fluid 335.86 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2018 SWEPI LP Produced Fluid 59.52 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123
2019 SWEPI LP Produced Fluid 34.97 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123
2019 SWEPI LP Produced Fluid 33.33 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC022
2019 SWEPI LP Produced Fluid 264.61 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2019 SWEPI LP Produced Fluid 541.97 Bbl REUSE (AT WELL PAD)
2019 SWEPI LP Produced Fluid 66.67 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR119

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2004682 Primary Facility 2011-09-22 Routine/Complete Inspection No Violations Noted
2025004 Primary Facility 2011-12-08 Routine/Complete Inspection No Violations Noted
2065291 Primary Facility 2012-04-09 Routine/Complete Inspection No Violations Noted
2065964 Primary Facility 2012-05-08 Routine/Complete Inspection No Violations Noted
2066231 Primary Facility 2012-05-09 Routine/Partial Inspection No Violations Noted A routine partial inspection was conducted at the Showalter pad on 5/9/12. The last inspection conducted on behalf of the operator was on 5/7/12 by Penn E&R. There was 17 wheelie tanks on-site and they were on containment. Several puddles on the pad (not on containment) were screened for elevated conductivity, none exhibited high readings. One area on containment had a reading of 4.27 mS. This was located near the wheelie tank N37013. There were multiple holes observed in the liner, but none in the area of the elevated reading. The cause of the elevated reading should be determined and corrected. The liquid on the liner should be collected and disposed of properly. The integrity of the liner should be retired as soon as possible. No erosion issued were observed during this inspection. No new violations were cited during this inspection. - MRN
2201786 Primary Facility 2013-09-03 Routine/Partial Inspection No Violations Noted An inspection of the Showalter 822 site in Chatham Township, Tioga County was conducted on September 3, 2013. The last inspection conducted on behalf of the operator was on 8/19/2013. The 1H, 2H and 4H wells were drilled and appeared to be in production, one additional well was spudded. No puddles exhibiting elevated conductivity or erosion issues were observed at this time. All area were well vegetated or otherwise stabilized, no issues were noted. No violations were cited during this inspection
2260457 Primary Facility 2014-02-11 Drilling/Alteration No Violations Noted
2442843 Primary Facility 2016-01-20 Complaint Inspection No Violations Noted The Department inspected the SWEPI LP site – Showalter 822 (ESX11-117-0011) located in Chatham Twp., Tioga Co. on 1/20/2016 @ 1115 hours. The weather was 18° and overcast with blustery winds and a dusting of snow and ice. A copy of the E&S plan was located in the mailbox along with the onsite inspection log, well permits and PPC Plan. The site was last inspected by company personnel on 1/14/2016 with “site snow covered” listed in the comments section. Total Project area is listed as 20.20 acres. The receiving stream is listed as “UNT to Crooked Creek/Susquehanna River Basin in PA” WWF designation.
2636093 Primary Facility 2017-09-14 Routine/Partial Inspection No Violations Noted EC readings with Oakton PCSTestr 35 (mS/cm): pad--0.25, containment--0.48.
2696042 Primary Facility 2018-02-20 Routine/Partial Inspection No Violations Noted Electrical conductivity (EC) readings taken with an Oakton PCSTestr 35. Puddle on pad gave a 0.25 mS/cm reading. Inspection logbook is in mailbox near production tank; last inspection listed February 17, 2018. Air temp 62F. JLP
2729673 Primary Facility 2018-05-14 Routine/Complete Inspection No Violations Noted The DEP conducted a routine inspection of the SWEPI LP-Showalter 822 Well Pad located in Chatham Township, Tioga County on May 14, 2018 at 1300 hrs. the weather was 73° and sunny. Winds WSW @9 mph, 53% humidity.

The current ESCGP-2 authorizes the expansion of the existing well pad by adding a 41,241 ft² section to the west, northwest, and south west side of the pad as well as the addition of a 200'x 200' tank pad. The well pad was previously in interim restoration with 4 wells observed drilled, 3 of which appear to be in production.

As of today's inspection contractor JL watts is in the process of expanding the pad. Temporary erosion and sediment control's appear to be installed as specified in the plan drawings. No erosion or sedimentation was observed.

No violations were noted at this time. Please contact me with any questions. I departed the site at 1420 hrs.

-ELN

2775759 Primary Facility 2018-09-17 Routine/Complete Inspection No Violations Noted The DEP conducted a routine inspection of the SWEPI LP - Showalter 822 well pad located in Chatham Twp, Tioga Co. on 917/2018 @1245 hours. The weather was 72 degrees and cloudy, winds N @11mph, 94% humidity. Present for the inspection was myself and Korey Starkey, DEP Env Trainee.

The access road, well pad, and E&S controls were observed. The current ESCGP-2 authorized the expansion of the existing well pad by adding a 41,241 ft² section to the west, northwest, and south west side of the pad as well as the addition of a 200'x 200' tank pad.

The well pad was previously in interim restoration with 4 wells observed drilled, 3 of which appear to be in production. 4 new well cellars were observed on the pad surface. An infiltration basin was observed below the north side of the well pad. Temporary BMPs were observed in the form of CFS below the newly constructed pony pad and below the pad expansion area. No erosion or sedimentation was observed onsite.

The site was last inspected by company on 9/15/2018 with n

For data sources see[8]

References