Well Details

Well ID: 37-117-21160
Loading map...
Country: United States
State: Pennsylvania
County: Tioga
Municipality: Osceola Township
Operator Name: SWEPI LP
Well Pad ID: 149357
Farm/Lease Name: STANLEY 1106 1V
License Status: INACTIVE
Spud Date:
Permit Date: 2011-01-25
Well Type: GAS
Unconventional Well: Y
Configuration: Vertical Well
Conservation: No
Latitude: 41.943158
Longitude: -77.356453

For data sources see[1][2][3]

Well History

Date Event
2011-01-25 New Permit Application
2011-03-02 Performed Spud Operation
2011-05-15 Drilling Completion
2012-08-16 NEWLY DRILLED
2013-08-24 Perforation

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2013-08-26 2013-08-28 5,174 61,614 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Bioclear 1000 Weatherford Kills Bacteria NA NA 100 0.0075469 42
AP Live Weatherford Breaks down gel Ammonium Persulfate 7727-54-0 100 0.13836 770
Proppant Shell Proppagates Frac Trade Secret NA 100 4.27478 23790
HECS-602 WST Increases fluid viscosity Distillates, petroleum, hydrotreated light 64742-47-8 60 0.21964 1222
Water / Produced Water Shell Carrier Fluid H2O + Disolved Salts NA 100 95.2132 529880

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2010 EAST RESOURCES MGMT LLC 0.00 0 0.00 0 0.00 0
2011 SWEPI LP 0.00 0 0.00 0 0.00 0
2012 SWEPI LP 0.00 0 0.00 0 0.00 0
2013 SWEPI LP 0.00 0 0.00 0 0.00 0
2014 SWEPI LP 0.00 0 0.00 0 0.00 0
2015 SWEPI LP 0.00 0 0.00 0 0.00 0
2016 SWEPI LP 0.00 0 0.00 0 0.00 0
2017 SWEPI LP 0.00 0 0.00 0 0.00 0
2019 SWEPI LP 0.00 0 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2013 SWEPI LP Fracing Fluid Waste 1,057.08 Bbl REUSE OTHER THAN ROAD SPREADING
2013 SWEPI LP Fracing Fluid Waste 156.40 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2073649 Primary Facility 2012-05-17 Routine/Complete Inspection No Violations Noted
2108249 Primary Facility 2012-10-15 Routine/Complete Inspection No Violations Noted
2144989 Primary Facility 2013-03-04 Follow-up Inspection No Violations Noted
2195771 Primary Facility 2013-08-15 Routine/Partial Inspection No Violations Noted On August 15, 2013 a routine partial inspection was conducted at the Stanley 1106 pad in Osceola Township, Tioga County. The last inspection conducted on behalf of the operator was on 8/13/2013: the only issue noted was that the cellars are holding water. There are seven drill permits issued for this site, the 1V and 2H wells have been drilled, the well tags installed and the permits are active. The status of the 1H, 3H, 4H, 5H and 6H well permits are listed as Operator Reported Not Drilled. The ESCGP is active. The site is well vegetated and stabilized. No puddles were observed on the pad surface and no issues were noted. No violations were cited during this inspection.
2205309 Primary Facility 2013-09-17 Routine/Complete Inspection No Violations Noted
2446944 Primary Facility 2016-02-02 Incident- Response to Accident or Event No Violations Noted The Department inspected the SWEPI LP - Stanley 1106 (ESX10-117-0243) located in Osceola Twp., Tioga Co. in response to notification of a spill by Patrick Bernethy, Environmental/Regulatory Tech from Shell Appalachia. Mr. Bernethy contact the WSQ @ 1150 hours on 1/26/2016 to notify the Department that SWEPI LP removed the temporary containment liner used during well completion activities on the 23 H well (API#117-21792) at the Stanley 1106 pad. As part of SWEPI LP’s standard procedures, soil conductivity readings were collected from the pad following the liner removal. Soil conductivity measurement points exhibited readings above background in the area of the temporary liner; approximately 6-8 mS. SWEPI LP was not notified during completion activities of any spills by the completions contractor, US Well Services.
2487535 Primary Facility 2015-05-26 Routine/Complete Inspection No Violations Noted

--off waste container onsite. The area was excavated ~6-7 inches down to the soil cement layer. SWEPI was in the process of back-filling the excavated area with clean material during this inspection. I departed the site @ 1045 hours. No violations are noted at this time.


Stanley 1106 1V 117-21160 Regulatory Inactive Status Stanley 1106 2H 117-21045 Active Stanley 1106 23H 117-21792 Active Stanley 1106 25H 117-21793 Active

Picture are attached the 23H API#117-21792 file copy of this inspection report.


2553028 Primary Facility 2017-01-18 Routine/Complete Inspection No Violations Noted The Department of Environmental Protection (DEP) conducted a routine inspection at the Stanley 1106 well site located in Deerfield Twp., Tioga Co. on 1/30/2017. The weather is 29° and cloudy northwest winds 13 mph. Three wells wereobserved drilled on the pad. Two wells appear to be in production. A large puddle near the well heads and some production equipment has a field measured conductivity of 150 microsiemens/cm. A new ESCGP-2 has been issued for the site to facilitate a pad build-out complete with installation of PCSM features. Cut and fill slopes appear stabilized by >70% perennial vegetation. No violations were noted during this inspection. Please contact me with any questions. Pictures are attached to the ESCGP file copy of the inspection report.
2595390 Primary Facility 2017-05-18 Routine/Partial Inspection No Violations Noted EC readings w an Oakton PCSTestr 35: wheelie trl liner--0.24 mS/cm, prod tank liner--0.50 mS/cm, basin--0.61

On site ~1355-1445 hrs

2639222 Primary Facility 2017-09-22 Site Restoration No Violations Noted Electrical conductivity readings with Oakton PCSTestr 35 (mS/cm): wheelie trailer containment--2.7, pad--0.45, production tank containment--0.51.

For data sources see[8]