X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-117-21123

Well Details

Well ID: 37-117-21123
Loading map...
Country: United States
State: Pennsylvania
County: Tioga
Municipality: Bloss Township
Operator Name: SENECA RESOURCES CO LLC
Well Pad ID: 148207
Farm/Lease Name: DCNR 595 55H 50451
License Status: PLUGGED & ABANDONED
Spud Date:
Permit Date: 2010-12-27
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.687147
Longitude: -77.127197

For data sources see[1][2][3]

Well History

Date Event
2010-12-27 New Permit Application
2011-01-13 Performed Spud Operation
2013-07-12 Drilling Completion
2015-03-26 FULLY PLUGGED
2015-03-26 NEWLY DRILLED

For data sources see[4]


Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2010 SENECA RESOURCES CO LLC 0.00 0 0.00 0 0.00 0
2011 SENECA RESOURCES CO LLC 0.00 0 0.00 0 0.00 0
2012 SENECA RESOURCES CO LLC 0.00 0 0.00 0 0.00 0
2013 SENECA RESOURCES CO LLC 0.00 0 0.00 0 0.00 0

For data sources see[5]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2071334 Primary Facility 2012-05-25 Follow-up Inspection No Violations Noted liquid in sump 2.2 mS/cm
2078030 Primary Facility 2012-06-20 Follow-up Inspection Outstanding Violations - No Viols Req'd digging out contaminated soil on pad
2164845 Primary Facility 2013-04-30 Routine/Complete Inspection No Violations Noted
2213667 Primary Facility 2013-10-17 Plugging(Includes Plugged/Mined Through) No Violations Noted
2364694 Primary Facility 2015-04-27 Routine/Partial Inspection No Violations Noted Overdue for restoration. 6 Marcellus gas wells in production
2513067 Primary Facility 2016-08-22 Routine/Complete Inspection No Violations Noted
2518324 Primary Facility 2016-09-12 Routine/Complete Inspection No Violations Noted -Inspection of Seneca Resources Corporation’s DCNR 595 Pad F in Bloss Twp. Tioga County conducted September 12, 2016 at 1:10 pm. There were (2) plugged wells and (6) active wells on the pad at the time of inspection.

-The 58H (Plugged 7-12-16) had casing cut below ground level, cellar filled with gravel, and had an 8’ high 3” candy cane vent. I detected no gas with an Altair 5x gas meter. The other plugged well was the 55H (Plugged 7-12-16). It appeared this one had casing cut in the cellar below ground level, filled with gravel, no above-ground monument. No gas detected in ambient air near the cellar. -The remaining (6) wells all had production trees in place (Active). I did a visual inspection of the wells. All the wells had digital pressure gauges on the tree top and off the production casing wing valve with not much pressure differential; either no tubing or pressure regulating tool in the tubing string. All wells had (1020-1094)PSI with the exception of the 38H only had 391PSI surface pressure. All th

For data sources see[6]

References