37-117-20977

Well Details

Well ID: 37-117-20977
Loading map...
Country: United States
State: Pennsylvania
County: Tioga
Municipality: Duncan Township
Operator Name: EQT PROD CO
Well Pad ID: 149048
Farm/Lease Name: PHOENIX 590887
License Status: Plugged and Abandoned
Spud Date:
Permit Date: 2010-10-28
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.649914
Longitude: -77.265114

For data sources see[1][2][3]

Well History

Date Event
2010-10-28 New Permit Application
2011-10-04 Performed Spud Operation
2011-10-25 Permit Renewal Application
2012-05-04 New Permit Application
2013-08-27 New Permit Application
2015-05-12 New Permit Application
2016-06-24 Begin Plugging
2016-07-11 Finished Plugging

For data sources see[4]


Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2010 EQT PROD CO 0.00 0 0.00 0 0.00 0
2011 EQT PROD CO 0.00 0 0.00 0 0.00 0
2012 EQT PROD CO 0.00 0 0.00 0 0.00 0
2013 EQT PROD CO 0.00 0 0.00 0 0.00 0
2014 EQT PROD CO 0.00 0 0.00 0 0.00 0
2015 EQT PROD CO 0.00 0 0.00 0 0.00 0
2016 EQT PROD CO 0.00 0 0.00 0 0.00 0

For data sources see[5]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2012 EQT PROD CO Drilling Fluid Waste 1,255.00 Bbl REUSE OTHER THAN ROAD SPREADING
2012 EQT PROD CO Drilling Fluid Waste 110.00 Bbl LANDFILL 301358
2012 EQT PROD CO Fracing Fluid Waste 260.00 Bbl REUSE OTHER THAN ROAD SPREADING
2012 EQT PROD CO Produced Fluid 100.00 Bbl INJECTION DISPOSAL WELL 34-155-21438
2015 EQT PROD CO Produced Fluid 200.00 Bbl INJECTION DISPOSAL WELL 34-007-21847
2015 EQT PROD CO Produced Fluid 320.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016 EQT PROD CO Fracturing Fluid Waste 520.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016 EQT PROD CO Servicing Fluid 6.79 Tons LANDFILL SWF 1032-WV0109
2016 EQT PROD CO Fracturing Fluid Waste 20.33 Tons LANDFILL 301358
2016 EQT PROD CO Produced Fluid 101.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NW011
2016 EQT PROD CO Produced Fluid 201.00 Bbl REUSE OTHER THAN ROAD SPREADING
2017 EQT PROD CO Produced Fluid 143.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2017 EQT PROD CO Other Oil & Gas Wastes 564.00 Bbl REUSE (AT WELL PAD)
2018 EQT PROD CO Other Oil & Gas Wastes 96.13 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2018 EQT PROD CO Other Oil & Gas Wastes 155.00 Bbl REUSE (AT WELL PAD)
2018 EQT PROD CO Other Oil & Gas Wastes 41.25 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW009
2018 EQT PROD CO Synthetic Liner Materials 23.95 Tons LANDFILL 301358
2018 EQT PROD CO Other Oil & Gas Wastes 9.12 Tons LANDFILL 301358

For data sources see[6]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1974945 Primary Facility 2011-05-13 Routine/Complete Inspection No Violations Noted RTNC insp. E&S viols against 883 inspection (#1974299). TLT
2001180 Primary Facility 2011-08-30 Routine/Complete Inspection No Violations Noted
2066394 Primary Facility 2012-05-09 Drilling/Alteration No Violations Noted
2126732 Primary Facility 2012-12-28 Routine/Partial Inspection No Violations Noted
2139761 Primary Facility 2013-02-06 Routine/Partial Inspection No Violations Noted
2145022 Primary Facility 2013-03-01 Routine/Partial Inspection No Violations Noted
2254682 Primary Facility 2014-02-27 Follow-up Inspection No Violations Noted
2301250 Primary Facility 2014-09-04 Routine/Complete Inspection No Violations Noted
2319526 Primary Facility 2014-11-06 Routine/Complete Inspection No Violations Noted
2328166 Primary Facility 2014-11-25 Routine/Partial Inspection No Violations Noted Drill rig recently moved off site. Site preparation and mobilization for frac ongoing during inspection. TLT
2336081 Primary Facility 2015-01-13 Administrative/File Review No Violations Noted Review of lab results for samples collected on 11/25/14 from standing water on pad surface following drilling operations. Results show concentrations that exceed Department standards for constituents indicative of oil and gas operations. Violations cited against Phoenix 590888 well permit (117-20981) TLT.
2343271 Primary Facility 2015-02-11 Routine/Complete Inspection No Violations Noted
2352475 Primary Facility 2015-03-11 Routine/Partial Inspection No Violations Noted Violation cited against Phoenix 590888 well (117-20981) during 3/11/15 inspection for failure to maintain E&S controls to prevent the potential for accelerated erosion and sedimentation. Access road to the site not maintained to prevent tracking of mud onto State Route 3009. Equipment mobilized to site the next day to sweep SR 3009 and improve stabilization on the access road. Violation immediately corrected. TLT
2367828 Primary Facility 2015-05-04 Follow-up Inspection No Violations Noted Follow up inspection to resolve 1/13/15 violations. New violations observed and cited against Phoenix 590888 well (117-20981). TLT
2375726 Primary Facility 2015-05-29 Follow-up Inspection No Violations Noted Follow up inspection to verify whether 5/4/15 violations (cited against 117-20981) have been resolved. Stained material still present. Sample 2519-626 collected. TLT
2407349 Primary Facility 2015-09-14 Follow-up Inspection No Violations Noted Follow up inspection to resolve the 5/4/15 violations against the Phoenix 590888 well (117-20981). EQT provided a follow up response on 6/8/15 that included soil sample results to document the cleanup. Concentrations were below applicable standards. 5/29/15 Department results were also below the applicable standards. TLT
2511839 Primary Facility 2016-08-16 Routine/Partial Inspection No Violations Noted Partial inspection to observe reclamation of Impoundment #1. Impoundment dewatered and liner removed. Gray subbase material observed on impoundment walls and floor. Field conductivity screening completed of standing water and impoundment floor soil. No violations cited. TLT
2530383 Primary Facility 2016-10-14 Routine/Complete Inspection No Violations Noted Routine inspection. Both freshwater impoundments and topsoil stockpile have been reclaimed. The east and south well pad corner sumps have been removed and an infiltration basin constructed southeast of the well pad. No violations cited. TLT
2531643 Primary Facility 2016-10-26 Plugging(Includes Plugged/Mined Through) No Violations Noted Inspection of EQT’s Phoenix 590997 (117-20977) plugged well in Duncan Twp. Tioga Co. conducted October 26, 2016 at 12:15 pm. At the time of inspection; the cellar was filled with water with 3” tagged standpipe monument about 8’ high. The top of the monument was open ended “T”, ran hose for Altair 5x gas meter in the vent; no gas detected. There were (7) active gas wells in production on the pad; #590885 (117-20966), #590884 (117-20975), #590883 (117-20974), #590892 (117-20985), #590890 (117-20983), #590889 (117-20982), #590888 (117-20981). Conducted visual inspection of WH and cellar; no obvious conecrns.
2535686 Primary Facility 2016-11-03 Site Restoration No Violations Noted Well Site Restoration Reports (WSRRs) received on 11/1/16. Since the new 25 Pa Code Ch. 78a regulations are in effect, WSRR's are to be submitted on the updated form through the Greenport website. This information was conveyed to EQT along with the request that the WSRRs be submitted electronically on the updated form. Interim restoration has been completed at the site and vegetative cover is becoming established. TLT
2544170 Primary Facility 2016-12-06 Site Restoration No Violations Noted Restoration inspection. Notice of Termination (NOT) received on 11/16/16 and Well Site Restoration Report submitted through Greenport on 12/6/16. Post-construction stormwater management BMPs have been installed. Vegetation is becoming established, however, entire site has not achieved 70% uniform vegetative cover and silt sock remains in place at the former Impoundment #1 location. Recommend that NOT be denied. Recommend that the NOT and WSRR be resubmitted after vegetation becomes more established and silt sock is removed. TLT
2596526 Primary Facility 2017-05-19 Site Restoration No Violations Noted On 5/19/17 at 1402 hrs I conducted an inspection of the Phoenix Pad R well site. No one was present during the inspection. It was mostly sunny and 84°F.

I observed the site and reviewed the erosion and sedimentation (E&S) routine inspection log, the Notice of Termination (NOT) and the Well Site Restoration Report (WSRR).

The well site has been restored and post-construction stormwater management (PCSM) BMPs have been installed. Temporary E&S controls have been removed and the project is permanently stabilized as per 25 Pa Code Section 102.22(a)(2). The last routine E&S inspection was conducted on 5/15/17.

Based on existing conditions, I recommend approval of the NOT. The WSRR was approved on 5/22/17. No violations were cited during this inspection. I concluded the inspection at 1433 hrs. TLT

2702163 Primary Facility 2018-03-06 Routine/Partial Inspection No Violations Noted The department of environmental protection conducted an inspection of the EQT Phoenix pad R in response to report of a spill to the ground surface received March 3, 2018 @1315 hours. Present onsite was Jim Kelley, EQT Assistant Superintendent.

A stuck dump valve caused an overfill of a 100 BBL capacity storage tank. EQT estimated the spill of produced water to be between 30-40 gallons. The fluid settled in a low area on the pad surface adjacent to the tank. The impacted area, approximately 15' x 5' x 10", was excavated and "burrito" wrapped in plastic until a waste rolloff container was delivered.

As of today's inspection, the impacted material has been moved to the rolloff container. The excavated area has been backfilled with clean gravel. Mr. Kelley reported the malfunctioning valve has been repaired. A copy of the monthly tank inspection report, required under 25 Pa Code 78a.57(i), was requested from the Operator.

I departed the site at 1400 hours.

2807939 Primary Facility 2018-11-28 Routine/Partial Inspection No Violations Noted The DEP conducted an INCIDENT inspection of the EQT Pad R site located in Duncan Twp, Tioga Co. on 10/28/2018 at 1015 hours in response to spill notification #338402.

Cory Guiles of EQT reported that at 2:40 pm on 11/27/2018, "there was a release of hydraulic fluid to the pad surface. There was a mechanical failure on a water truck that allowed 20 gallons of hydraulic fluid to be released to the pad surface of Phoenix R. They are in the process of cleaning up the impacted soil now and will store it in drums."

As of today's inspection, no personnel were located onsite. I contacted Corey Giles, EQT to confirm the location of the spill. He stated he was under the impression it was in front of the production tanks, approximately 1 barrel of material was removed and had already been backfilled with clean material. During the course of the inspection Tim Ryan, EQT well tender appeared onsite and showed me the location of the spill. A small area adjacent to the well heads appears to have been recently disturbed.

For data sources see[7]