37-117-20880

Well Details

Well ID: 37-117-20880
Loading map...
Country: United States
State: Pennsylvania
County: Tioga
Municipality: Charleston Township
Operator Name: SWEPI LP
Well Pad ID: 147877
Farm/Lease Name: BURKE 285 1V
License Status: Plugged and Abandoned
Spud Date: 2010-11-04
Permit Date: 2010-09-01
Well Type: GAS
Unconventional Well: Y
Configuration: Vertical Well
Conservation: No
Latitude: 41.781139
Longitude: -77.223461

For data sources see[1][2][3]

Well History

Date Event
2010-09-01 New Permit Application
2010-11-01 Performed Spud Operation
2010-11-17 Drilling Completion
2012-08-16 NEWLY DRILLED
2014-05-09 Inactive Well Request Granted
2018-06-07 Begin Plugging
2018-06-10 Finished Plugging
2018-07-18 Fully Plugged

For data sources see[4]


Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2010 EAST RESOURCES MGMT LLC 0.00 0 0.00 0 0.00 0
2011 SWEPI LP 0.00 0 0.00 0 0.00 0
2012 SWEPI LP 0.00 0 0.00 0 0.00 0
2013 SWEPI LP 0.00 0 0.00 0 0.00 0
2014 SWEPI LP 0.00 0 0.00 0 0.00 0
2015 SWEPI LP 0.00 0 0.00 0 0.00 0
2016 SWEPI LP 0.00 0 0.00 0 0.00 0
2017 SWEPI LP 0.00 0 0.00 0 0.00 0

For data sources see[5]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1971373 Primary Facility 2011-04-28 Routine/Complete Inspection Violation(s) Noted
2007645 Primary Facility 2011-09-29 Follow-up Inspection No Violations Noted FUI to correct 4/28/11 E&S viol. TLT
2110007 Primary Facility 2012-10-22 Routine/Complete Inspection No Violations Noted
2406737 Primary Facility 2015-09-14 Routine/Complete Inspection No Violations Noted
2479664 Primary Facility 2016-04-25 Complaint Inspection No Violations Noted Complaint inspection. The 5H & 6H wells were being plugged at time of complaint. The 5H and 6H wells were spud on 12/8/11 (80' of conductor pipe installed), however never drilled. A stained area was noted on pad surface. Staining was grayish-brown in color. SWEPI stated that cellar water and surface water which had accumulated in the conductor pipe was discharged to pad surface to infiltrate. Staining on pad was surficial. Requested that SWEPI evaluate stained area and determine whether remedial actions are necessary. TLT
2496295 Primary Facility 2016-06-28 Routine/Complete Inspection No Violations Noted
2560964 Primary Facility 2017-02-10 Routine/Partial Inspection No Violations Noted Partial inspection. Site idle and snow covered. 1H - 4H have been partially drilled to depth of 2030' (according to Well Record Reports). The 5H & 6H wells were plugged in April 2016. The 1V well was placed on inactive status on 5/9/14. SWEPI's two-year restoration extension request was approved on 5/4/16. A new ESCGP2 application is currently under review. Permanent stablization and E&S controls were not observed due to the snow cover. No violations were cited during the inspection. TLT
2602978 Primary Facility 2017-06-06 Routine/Partial Inspection No Violations Noted Puddle on pad 0.18 mS/cm w an Oakton PCSTestr 35. Onsite ~1415-1510.
2742732 Primary Facility 2018-06-15 Plugging(Includes Plugged/Mined Through) No Violations Noted A routine inspection of this plugged vertical unconventional well was conducted June 15, 2018. The rig and equipment are off location following plug and abandonment. The well is now plugged, cut, marked and buried below grade. There were no open holes, discharges, venting, or other issues observed. No gas was detected at the surface location of the plugged well.
2779461 Primary Facility 2018-09-25 Plugging(Includes Plugged/Mined Through) No Violations Noted Routine (pre-plugging) inspection of 4 wells on the pad which are "top-holed"; surface/intermediate casings installed and cemented, cemented shoe track in 9 5/8" casing, and no openhole below the casing shoe. It was reported no oil or gas zones were encountered. At the time of inspection, all four wells had cellars full of gravel. Wells are capped. Annular vents were present. No gas was detected at the vents or in the gravel next to well caps. Also on location is the recently plugged 1V well which is cut and buried. There were no open holes, discharges, venting, or any other obvious issues observed on location during this inspection.

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
1971373 610562 04/28/2011 2011-04-28 102.4 - Failure to minimize accelerated erosion, implement E&S plan, maintain E&S controls. Failure to stabilize site until total site restoration under OGA Sec 206(c)(d) Environmental Health & Safety 102.4(b)(1). Erosion gullies noted. Additional stabilization needed. ECB not installed as per plan. TLT

For data sources see[6]