37-117-20735

Well Details

Well ID: 37-117-20735
Loading map...
Country: United States
State: Pennsylvania
County: Tioga
Municipality: Union Township
Operator Name: ROCKDALE MARCELLUS LLC
Well Pad ID: 149555
Farm/Lease Name: WESNESKI 724 1V
License Status: INACTIVE
Spud Date:
Permit Date: 2010-06-02
Well Type: GAS
Unconventional Well: Y
Configuration: Vertical Well
Conservation: No
Latitude: 41.621717
Longitude: -76.897528

For data sources see[1][2][3]

Well History

Date Event
2010-06-02 New Permit Application
2010-07-11 Performed Spud Operation
2010-08-13 Drilling Completion
2010-12-17 Drilling Completion
2011-02-03 NEWLY DRILLED
2012-07-16 SKIDDED RIG

For data sources see[4]


Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2010 EAST RESOURCES MGMT LLC 0.00 0 0.00 0 0.00 0
2011 SWEPI LP 0.00 0 0.00 0 0.00 0
2012 SWEPI LP 0.00 0 0.00 0 0.00 0
2013 SWEPI LP 0.00 0 0.00 0 0.00 0
2014 SWEPI LP 0.00 0 0.00 0 0.00 0
2015 SWEPI LP 0.00 0 0.00 0 0.00 0
2016 SWEPI LP 0.00 0 0.00 0 0.00 0
2017 SWEPI LP 0.00 0 0.00 0 0.00 0
2019 ROCKDALE MARCELLUS LLC 0.00 0 0.00 0 0.00 0

For data sources see[5]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2013 SWEPI LP Produced Fluid 19.05 Bbl REUSE OTHER THAN ROAD SPREADING

For data sources see[6]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1921099 Primary Facility 2010-10-19 Compliance Evaluation No Violations Noted Waiver Request for setback from stream
1955023 Primary Facility 2011-03-05 Compliance Evaluation Violation(s) Noted site built within 100' of stream
1996297 Primary Facility 2011-08-17 Routine/Complete Inspection Violation(s) Noted fill slop washed out
2000339 Primary Facility 2011-09-02 Follow-up Inspection No Violations Noted to close 601.205b and 102.4 viols
2502213 Primary Facility 2016-07-15 Routine/Complete Inspection No Violations Noted Routine inspection to assess overall site conditions. No SWEPI representatives were present.

Vegetative cover on site is greater than 70% with interspersed rocky areas. No evidence of accelerated erosion or sedimentation was observed.

A 2-year extension of time for site restoration was approved by the Department on March 07, 2016. The post construction stormwater management features approved as part of the extension request consist of an existing sediment basin and several rock lined swales. These features are in place and in good repair.

No violations were cited during this inspection.

2743908 Primary Facility 2018-06-21 Routine/Complete Inspection No Violations Noted Waiting on cement truck to cement cellars.
2755227 Primary Facility 2018-07-24 Routine/Complete Inspection No Violations Noted Weather was 72 degrees and raining. It had been raining for a few days at time of inspection. Met with Jimmy Larsen at time of inspection. Well is closed in. A bridge plug was set near the surface on this well before drilling commenced on the 2 newer wells on the pad. 0% combustible gas was detected around the well at time of inspection. No violations were noted at time of inspection.
2760882 Primary Facility 2018-08-06 Routine/Complete Inspection No Violations Noted Weather was 72° and sunny at time of inspection. Met with Rockdale Marcellus representative Jimmy Larsen at time of inspection. Well was closed in. A bridge plug was set near the surface on this well before drilling commenced on the 2 newer wells on the pad. Cellar conditions did not appear to have changed from previous inspection. 0% combustible gas was detected around the well at time of inspection. No violations were noted at time of inspection.
2771604 Primary Facility 2018-09-06 Routine/Complete Inspection No Violations Noted Weather was 78° and partly cloudy at time of inspection. Met with Rockdale Marcellus representative Danny Brooks on location. Well was shut in at time of inspection. Well was preexisting on location. Well had 1 annulus vents plumbed to surface at time of inspection. No violations were noted at time of inspection.
2776848 Primary Facility 2018-09-19 Routine/Complete Inspection No Violations Noted Weather was 68° and cloudy at time of inspection. There were no Rockdale Marsellus representatives on location at time of inspection. Well had one annulus vent plum to surface by 2 inch pipe. 0% combustible gas was the tech did on the anulus event at time of inspection. Well had one 0-5k psi analog pressure gauge attached to a wing valve that read 0 psi at time of inspection. No violations were noted at time of inspection.
2793379 Primary Facility 2018-10-23 Plugging(Includes Plugged/Mined Through) No Violations Noted A routine plugging inspection of the Wesneski 724 1V was conducted October 23, 2018. At the time of inspection, a coil tubing rig is on location for final plug and abandonment. I spoke with the companyman to discuss operations on the pad and plugging procedure. No plugs have been set yet; they must first drill out existing retainer set in the 4 1/2" by previous operator. After drillout they will isolate perfs (6323'-6333) with CIBP and spot remaining cement plugs on CIBP and across intermediate and surface casing shoe depths (in 4 1/2") with dump bailer on WL. Gel spacers between plugs and gravel above surface casing plug to surface. 4 1/2" casing is reportedly cemented to surface and unrecoverable. There was reportedly no pressure outside of production casing. No issues were reported outside of production casing. No obvious issues were observed during this inspection.
2794369 Primary Facility 2018-10-24 Plugging(Includes Plugged/Mined Through) No Violations Noted A routine plugging inspection of the Wesneski 724 1V was conducted October 24 2018. Coil tubing is off location after an attempt at final plug and abandonment. I spoke with the companyman to discuss operations on the pad since my site visit yesterday. The rig had difficulty drilling through an obstruction in the tophole section of the wellbore thought to have been a retainer but not listed on well records from previous operator. Plugging operations are shut down at this time, resumption of operations pending further investigation. At the well, cellar is full of water; no bubbling. Casing head is on 7" with (4 1/2" x 7") annular vent; no visible/audible venting or pressure felt. B section and master valve on production casing. No immediate issues were observed.
2803374 Primary Facility 2018-11-15 Administrative/File Review No Violations Noted Results were received for sample ID #0939077 taken on 10/17/2018 (see pictures). Sample was taken from a 15-20gallon puddle located outside of containment. Elevated barium, strontium, and chlorides indicate that the fluid on the pad was wastewater; the result of the administrative inspection is Violations Noted.
2824875 Primary Facility 2019-01-09 Routine/Complete Inspection No Violations Noted Light activity on the site when I arrived. 2 temporary sand separators currently hooked up to the recently fraced wells. The onsite modular storage structure was still present, but a worker was pumping water from the tank to a bank of Baker tanks in containment. The area around the MASS was dry, and a downgradient sediment trap nearby showed low conductance (.13 mS/cm). A truck loading area at the Baker tanks had a 10' x 5' (1-2" deep) in front of it that showed slightly elevated conductance; I recommend that the puddle be vacced. The area where I noted fluid with elevated conductance on my 10/17/18 inspection had recently had fresh gravel placed on it.

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
1955023 605978 03/05/2011 2011-03-05 601.101 - O&G Act 223-General. Used only when a specific O&G Act code cannot be used Administrative
1996297 617954 08/17/2011 2011-08-17 102.4 - Failure to minimize accelerated erosion, implement E&S plan, maintain E&S controls. Failure to stabilize site until total site restoration under OGA Sec 206(c)(d) Environmental Health & Safety

For data sources see[7]

References