37-117-20664

Well Details

Well ID: 37-117-20664
Loading map...
Country: United States
State: Pennsylvania
County: Tioga
Municipality: Charleston Township
Operator Name: SWEPI LP
Well Pad ID: 146774
Farm/Lease Name: ALLEN 620-1V
License Status: Plugged and Abandoned
Spud Date: 2010-06-12
Permit Date: 2010-04-21
Well Type: GAS
Unconventional Well: Y
Configuration: Vertical Well
Conservation: No
Latitude: 41.684622
Longitude: -77.268933

For data sources see[1][2][3]

Well History

Date Event
2010-04-21 New Permit Application
2010-06-11 Performed Spud Operation
2010-07-08 Drilling Completion
2010-08-09 NEWLY DRILLED
2013-06-04 Inactive Well Request Granted
2018-04-25 Begin Plugging
2018-04-28 Finished Plugging
2019-01-24 Fully Plugged

For data sources see[4]


Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2010 EAST RESOURCES MGMT LLC 0.00 0 0.00 0 0.00 0
2011 SWEPI LP 0.00 0 0.00 0 0.00 0
2012 SWEPI LP 0.00 0 0.00 0 0.00 0
2013 SWEPI LP 0.00 0 0.00 0 0.00 0
2014 SWEPI LP 0.00 0 0.00 0 0.00 0
2015 SWEPI LP 0.00 0 0.00 0 0.00 0
2016 SWEPI LP 0.00 0 0.00 0 0.00 0
2017 SWEPI LP 0.00 0 0.00 0 0.00 0

For data sources see[5]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2018 SWEPI LP Produced Fluid 231.00 Bbl REUSE (AT WELL PAD)

For data sources see[6]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1909530 Primary Facility 2010-08-27 Routine/Complete Inspection No Violations Noted Initial well pad complete, vertical drilled.
2154307 Primary Facility 2013-04-05 Follow-up Inspection No Violations Noted
2515864 Primary Facility 2016-08-30 Routine/Complete Inspection No Violations Noted
2695407 Primary Facility 2018-02-14 Routine/Complete Inspection No Violations Noted Routine pre-plugging inspection of a vertical gas well. At the time of inspection: the well was shut in with nightcap bolted atop spool/hanger. There was a needle valve with an analog pressure gauge which read approximately 1600 PSI. The cellar was full of gravel with 4 annular vents coming up out of the gravel. No visual or audible flow was coming from the vents. I checked each vent with my hand; no pressure felt. No gas was detected with an Altair 5x gas meter at the vents.
2696963 Primary Facility 2018-02-22 Routine/Complete Inspection No Violations Noted Routine inspection of the Allen 620 IV attempted February 22, 2018. Plugging operations were tentatively scheduled to begin today according to Notice of Intent to Plug form submitted by the operator. At the time of attempted inspection; no crew or equipment was observed on the pad. A large truck was parked sideways across the lease road, obstructing access to the facility.
2722208 Primary Facility 2018-04-24 Routine/Complete Inspection No Violations Noted I arrived at the Allen 620 lease road on April 24, 2018 to conduct a routine plugging inspection. Operations were scheduled to begin today. The rig was pulling onto location when I arrived. I discussed the procedure briefly with a companyman and left, planning to return later this week once plugging operations begin.
2724109 Primary Facility 2018-04-26 Plugging(Includes Plugged/Mined Through) No Violations Noted A routine, plugging inspection of the Allen 620 1V vertical, unconventional well was conducted April 26, 2018. At the time of inspection, a rig is on location for plug and abandonment. Cementers are on location, circulating hole at the time of inspection with good returns. The pump operator shut down and I inspected all 4 annular vents (2 for backside of production casing where a pipe nipple and valve comes out of the 7" and 2 for backside of the intermediate presumably although the source of this vent was buried in cellar.) There was no visual or audible flow from the vents and no pressure felt. The pump operator mixed cement, came online and pumped bottom plug and displaced to balance with no issues and good returns. Cementers shut down and the rig pulled tubing out of the hole to spot the second half of the bottom plug. The well was dead and tubing pulled dry. They plan to finish the bottom plug, WOC overnight, tag, and pump tophole cement plugs tomorrow. No issues were observed.
2724153 Primary Facility 2018-04-27 Plugging(Includes Plugged/Mined Through) No Violations Noted A routine, plugging inspection of the Allen 620 1V was conducted April 27, 2018. At the time of inspection, a rig was on location for plug and abandonment. All cement plugs have been set at this time and the operator plans to cut and cap well tomorrow. I conducted a final gas check before the operator cuts, caps, and buries this plugged well. BOP was still nippled up, and the operator lined out 4 1/2" casing to side outlet on the BOP. No audible or visible flow of gas was observed coming from the well and no gas detected with an Altair 5x gas meter. No gas was observed or detected with a gas meter at the annular vents. No obvious issues were observed during this inspection.
2727281 Primary Facility 2018-05-08 Administrative/File Review No Violations Noted May 8th, 2018: The Certificate of Plugging for the Allen 620 1V has been received, reviewed, signed, and sent to file.
2728604 Primary Facility 2018-05-10 Plugging(Includes Plugged/Mined Through) No Violations Noted A routine inspection of this plugged, vertical, unconventional well was conducted May 10, 2018. At the time of inspection; all equipment is off location following plug and abandonment. The well has been cut below grade and buried. There was no venting, bubbling, gurgling, or other obvious plugging-related issues observed at the surface location of the plugged well. No gas was detected with an Altair 5x gas meter at ground level above the plugged well.

For data sources see[7]