X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-117-20532

Well Details

Well ID: 37-117-20532
Loading map...
Country: United States
State: Pennsylvania
County: Tioga
Municipality: Brookfield Township
Operator Name: TENASKA RES LLC
Well Pad ID: 149398
Farm/Lease Name: SYLVESTER 1H
License Status:
Spud Date:
Permit Date: 2009-12-21
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: Yes
Latitude: 41.974872
Longitude: -77.560439

For data sources see[1][2][3]

Well History

Date Event
2009-12-21 New Permit Application
2009-12-29 Performed Spud Operation
2010-03-11 Drilling Completion
2010-04-23 DEVIATED
2010-08-25 Perforation

For data sources see[4]


Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2010 21,019.00 49 0.00 0 0.00 0
2011 0.00 0 0.00 0 0.00 0
2012 TENASKA RES LLC 0.00 0 0.00 0 0.00 0
2013 TENASKA RES LLC 115,458.00 204 0.00 0 0.00 0
2014 TENASKA RES LLC 120,292.00 361 0.00 0 0.00 0
2015 TENASKA RES LLC 85,019.00 364 0.00 0 0.00 0
2016 TENASKA RES LLC 66,419.00 366 0.00 0 0.00 0
2017 TENASKA RES LLC 62,534.00 350 0.00 0 0.00 0
2018 TENASKA RES LLC 62,850.00 304 0.00 0 0.00 0
2019 TENASKA RES LLC 46,200.00 304 0.00 0 0.00 0

For data sources see[5]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2011 Produced Fluid 559.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW018
2013 TENASKA RES LLC Produced Fluid 110.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR119
2013 TENASKA RES LLC Produced Fluid 465.19 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC010
2013 TENASKA RES LLC Produced Fluid 220.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC018
2013 TENASKA RES LLC Produced Fluid 206.24 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW018
2014 TENASKA RES LLC Produced Fluid 1,358.61 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2014 TENASKA RES LLC Produced Fluid 783.24 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC010
2015 TENASKA RES LLC Produced Fluid 863.91 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC010
2015 TENASKA RES LLC Produced Fluid 67.38 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2016 TENASKA RES LLC Produced Fluid 7,154.90 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC010
2016 TENASKA RES LLC Other Oil & Gas Wastes 80.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC010
2016 TENASKA RES LLC Other Oil & Gas Wastes 66.05 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2016 TENASKA RES LLC Produced Fluid 419.19 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2017 TENASKA RES LLC Produced Fluid 242.57 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123
2017 TENASKA RES LLC Produced Fluid 415.47 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2018 TENASKA RES LLC Produced Fluid 336.42 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2018 TENASKA RES LLC Other Oil & Gas Wastes 110.02 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123
2018 TENASKA RES LLC Other Oil & Gas Wastes 79.19 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2019 TENASKA RES LLC Produced Fluid 316.69 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2019 TENASKA RES LLC Other Oil & Gas Wastes 182.66 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2019 TENASKA RES LLC Produced Fluid 237.10 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123

For data sources see[6]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1861700 Primary Facility 2010-02-02 Compliance Evaluation Viol(s) Noted & Immediately Corrected self reported spill. cleaned up. closed. MAB
1861883 Primary Facility 2009-11-05 Complaint Inspection Violation(s) Noted
1861885 Primary Facility 2009-12-14 Compliance Evaluation No Violations Noted evaluation of violations cited on 11/5/2009. Chapter 102 violations corrected. MAB
1890461 Primary Facility 2010-06-09 Routine/Complete Inspection Violation(s) Noted RTNC Insp to investigate E&S issues.
1928080 Primary Facility 2010-11-10 Compliance Evaluation No Violations Noted Follow up inspection to resolve violations from 6/9/10 (#1890461). E&S viols corrected.
1964536 Primary Facility 2011-04-07 Routine/Complete Inspection Violation(s) Noted
1966655 Primary Facility 2011-04-14 Routine/Complete Inspection Violation(s) Noted RTNC Insp.
1976637 Primary Facility 2011-05-16 Follow-up Inspection Outstanding Violations - Viols Req'd 102.22(a) viol cited 4-14-11 (#1966655) remains outstanding. TLT
2001365 Primary Facility 2011-09-06 Follow-up Inspection No Violations Noted FUI Insp to close 4/14/11 and 5/16/11 E&S violations.
2062329 Primary Facility 2012-04-25 Routine/Complete Inspection Pending The cut slope above the pad (below the frac tank pad) does not have perennial vegetation established. The growth should be monitored and re-seeded if necessary. A series of small puddles near the well exibited elevated readings for specific conductance (approximately 3-4 µS). A sample of the puddles and a sample of the surronding soils was collected and submitted for laboratory anlaysis. Violations are pending the results. James Wood was made aware of the situation via email at 1645 on the day of the inpsection. At that time it was recommended the soil be screened to determine the extent of the release. - MRN
2068978 Primary Facility 2012-05-18 Follow-up Inspection Violation(s) Noted Laboratory results for sample 0940-016 (the puddle) were received and indicated Barium was present in the liquid found on the pad surface at a concentration of 20,100 µg/L. This is approximately 10 times the primary standard MCL. Consequently, the Department’s inspections revealed violations of the Clean Streams Law, 35 P.S. § 691.1 et seq.; the Solid Waste Management Act, 35 P.S. § 6018.101 et seq; and Chapter 78.54.
2083973 Primary Facility 2012-07-18 Follow-up Inspection Outstanding Violations - No Viols Req'd A site visit was conducted to discuss the action to be undertaken by Tenaska in response to a Notice of Violation received as a result of an inspection conducted at the Sylvester Pad on April 25, 2012. During today's inspection the specific location of the puddle was identified and the approximate locations for test pits, the initial area to be excavated and areas where background samples could be collected were discussed. Bryan McConnell from Tenaska indicated that additional permits to drill have been applied for and are in process.- MRN
2143244 Primary Facility 2013-02-27 Follow-up Inspection Outstanding Violations - No Viols Req'd On February 27, 2013 a follow-up inspection was conducted at the Sylvester pad in Brookfield Township, Tioga County to follow up issues noted during a May 18, 2012 inspection (2068978). Material had been removed from the pad and stockpiled adjacent to the excavation and covered with a tarp. The violations cited during the 5/18/12 inspection (against the 1H well; 117-20532) remain outstanding at this time. No new violations were cited during this inspection.
2145685 Primary Facility 2013-03-07 Compliance Evaluation No Violations Noted On March 7, 2013 a Compliance Evaluation inspection was conducted at the Sylvester pad in Brookfield Township, Tioga County to follow up issues noted during a May 18, 2012 inspection (2068978). The impacted soil has been excavated and the area backfilled. Conductivity readings of several puddles on the pad were taken and none exhibited elevated readings. The violations cited during the May 18, 2012 inspection are considered resolved. No new violations were cited during this inspection. - MRN
2315793 Primary Facility 2014-10-15 Routine/Complete Inspection No Violations Noted The Department inspected the Tenaska, Inc. Sylvester well pad in Brookfield Twp., Tioga Co. on 10/15/14 @ 1140 hours. An adequate site ID sign was observed at the entrance. A well tag was observed on the Sylvester 1H well head, permit# 37-117-20532. The pad surface measured 280’ x 185’. Approximately 280’ x 80’ of the pad surface had been seeded and was growing vegetation. This area had not been regarded before being seeded. The cut slope contained ~60-70% vegetation. The fill slopes were fully vegetated and appeared stable. The cellar around the well head did contain some standing water. Puddles were observed on the pad surface and the conductivity was measured at 150 µs/cm. The containment around the produced fluid tanks contained standing water and the conductivity was measured at 750 µs/cm.
2380939 Primary Facility 2015-06-10 Site Restoration No Violations Noted An adequate site ID sign was observed at the entrance. A well tag was observed on the Sylvester 1H well head, permit# 37-117-20532. The pad surface measured 280’ x 185’. Approximately 280’ x 80’ of the pad surface had been seeded and was growing vegetation. This area had not been regraded to original contours before being seeded. The cut slope contained ~60-70% vegetation. Silt sock is still visible on the south side of the cut slope near the corner of the pad surface and the haul road. The fill slopes were fully vegetated and appeared stable. The PCSM/site restoration plan accompanying this NOT shows E&S controls are to be "reclaimed and restored to original control". At the time of this inspection, stilling basins/level spreaders are still visible but appear to contain ~70% vegetation. Silt sock is still visble along the haul road (see attached pictures).
2549128 Primary Facility 2017-01-04 Routine/Complete Inspection No Violations Noted Routine inspection conducted at the Tenaska Resources Sylvester 1H well pad in Brookfield Township, Tioga County. Paul Torok, well tender for Victory Energy was onsite during my inspection. Mr. Torok last inspected the site on 12/31/2016 as noted in the onsite inspection log. A copy of the E&S plan was not available in mailbox. All E&S BMPs appear to be stabilized and functional. Cut and fill slopes appear to be stabilized with greater than 70% vegetative cover. Fluid was observed in the secondary containment surrounding the produced fluids tanks. The fluid conductivity was field measured at 126 microsiemens/cm, consistent with precipitation. No violations are noted at this time. Please contact me with any questions.
2549129 Primary Facility 2017-01-04 Routine/Complete Inspection No Violations Noted Routine inspection conducted at the Tenaska Resources Sylvester 1H well pad in Brookfield Township, Tioga County. Paul Torok, well tender for Victory Energy was onsite during my inspection. Mr. Torok last inspected the site on 12/31/2016 as noted in the onsite inspection log. A copy of the E&S plan was not available in mailbox. All E&S BMPs appear to be stabilized and functional. Cut and fill slopes appear to be stabilized with greater than 70% vegetative cover. Fluid was observed in the secondary containment surrounding the produced fluids tanks. The fluid conductivity was field measured at 126 microsiemens/cm, consistent with precipitation. No violations are noted at this time. Please contact me with any questions. Pictures are included in the site inspection file copy of this inspection report.
2813273 Primary Facility 2018-12-11 Routine/Complete Inspection No Violations Noted The DEP conducted a routine inspection of Tenaska Resource's Sylvester Well Pad in Brookfield Twp, Tioga County on 12/11/2018 at 1235 hours. The weather was partly cloudy, sunny and 28 degrees.

There is currently one producing well onsite with two production tanks. The pad is partially snow covered and fluids on the pad surface were frozen. Fluid within the GPU containment had a field measured conductivity of 200 us/cm today. The landowner is storing a few pieces of farming equipment onsite. No erosional issues were observed. The pad is very well vegetated and stabilized.

No issues or violations noted. I departed the site at 1300 hours.

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
1861700 580932 02/02/2010 2010-02-02 601.101 - O&G Act 223-General. Used only when a specific O&G Act code cannot be used Administrative 78.56 failure to contain pollutional substance - See Insp result VIOIC, closed.
1861883 580981 11/05/2009 2009-11-05 102.4INADPLN - E&S Plan not adequate Administrative See Insp ID 1861885, past viols closed.
1861883 580982 11/05/2009 2009-11-05 102.4 - Failure to minimize accelerated erosion, implement E&S plan, maintain E&S controls. Failure to stabilize site until total site restoration under OGA Sec 206(c)(d) Environmental Health & Safety See Insp ID 1861885, past viols closed.
1890461 589192 06/09/2010 2010-06-09 102.4 - Failure to minimize accelerated erosion, implement E&S plan, maintain E&S controls. Failure to stabilize site until total site restoration under OGA Sec 206(c)(d) Environmental Health & Safety Gully erosion along west and east slopes of well pad and on south slope of frac tank storage site. Serious cracking of well pad along the western and eastern edges of the pad. TLT
1890461 589193 06/09/2010 2010-06-09 78.56FRBRD - Failure to maintain 2' freeboard in an impoundment Administrative Failure to contain a pollutional substance. Evidence of black staining on soil in vicinity of two tanks on site. TLT
1964536 608477 04/07/2011 2011-04-07 78.86* - Failure to report defective, insufficient, or improperly cemented casing w/in 24 hrs or submit plan to correct w/in 30 days Administrative
1964536 608480 04/07/2011 2011-04-07 201TAG - Failure to install, in a permanent manner, the permit number on a completed well Administrative
1966655 609132 04/14/2011 2011-04-14 102.22 - Failure to achieve permanent stabilization of earth disturbance activity. Administrative 102.22 for failure to establish permanent vegetation. Cut and fill slopes of frac tank storage area are still not vegetated, even though this has been documented in two prior inspections. TLT
1976637 612329 05/16/2011 2011-05-16 102.4NOPLAN - No E&S plan developed, plan not on site Administrative 102.4(b)(8) for failure to maintain routine E&S inspection reports on site.
2068978 639695 04/25/2012 2012-04-25 78.54* - Failure to properly control or dispose of industrial or residual waste to prevent pollution of the waters of the Commonwealth. Environmental Health & Safety
2068978 639696 05/18/2012 2012-05-18 SWMA301 - Failure to properly store, transport, process or dispose of a residual waste. Environmental Health & Safety
2068978 639697 05/18/2012 2012-05-18 402CSL - Failure to adopt pollution prevention measures required or prescribed by DEP by handling materials that create a danger of pollution. Environmental Health & Safety

Penalties Applied

Violation ID Penalty ID Penalty Code Penalty Status Penalty Date Enforcement Date Penalty Amount Amount Collected
589192 260409 NOV - Notice of Violation Comply/Closed 2010-11-10
589193 260409 NOV - Notice of Violation Comply/Closed 2010-11-10
639695 283982 NOV - Notice of Violation Comply/Closed 2013-03-07
639696 283982 NOV - Notice of Violation Comply/Closed 2013-03-07
639697 283982 NOV - Notice of Violation Comply/Closed 2013-03-07

For data sources see[7]