If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-115-22089 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.797626,"lon":-75.62325,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Susquehanna | |
Municipality: Gibson Township | |
Operator Name: CABOT OIL & GAS CORP | |
Well Pad ID: 152997 | |
Farm/Lease Name: ROMEIKA J 4 | |
License Status: | |
Spud Date: | |
Permit Date: 2015-10-20 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: No | |
Latitude: 41.797626 | |
Longitude: -75.623250 |
Date | Event |
---|---|
2015-10-20 | New Permit Application |
2016-09-25 | Performed Spud Operation |
For data sources see[4]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2017-06-27 | 2017-07-28 | 7,146 | 20,613,100 | 0 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | Friction Reducer, KFR-20 | Keane | Friction Reducer | Petroleum distillate | 64742-47-8 | 1 | 0.00101253 | 1988.72 |
alcohols, C 12-16, ethoxylated | 68551-12-2 | 5 | 0.00506264 | 9943.6 | ||||
Copolymer of 2-propenamide | 69418-26-4 | 5 | 0.00506264 | 9943.6 | ||||
ammonium chloride | 12125-02-9 | 30 | 0.0303759 | 59661.6 | ||||
oleic acid diethanolamide | 93-83-4 | 1 | 0.00101253 | 1988.72 | ||||
Water | 7732-18-5 | 30 | 0.0303759 | 59661.6 | ||||
Other Chemical(s) | Listed Above | See Trade Name(s) List | quaternary ammonium compounds, benzyl-C12-16-alkyldimethyl, chlorides |
68424-85-1 | 5.3 | 0.000476146 | 935.204 | |
Glutaral | 111-30-8 | 26.7 | 0.00239418 | 4702.44 | ||||
organic phosphonic salts | 15827-60-8 | 15 | 0.00264927 | 5203.46 | ||||
alcohols, C 12-16, ethoxylated | 68551-12-2 | 5 | 0.00506264 | 9943.6 | ||||
Cinnamaldehyde | 104-55-2 | 10 | 0.00007484 | 146.992 | ||||
Citric acid | 77-92-9 | 30 | 0.000631689 | 1240.71 | ||||
Tar bases, quinoline derivs., benzyl chloride-quaternized | 72480-70-7 | 10 | 0.00007484 | 146.992 | ||||
dipropylene gylcol, monomethyl ether | 34590-94-8 | 20 | 0.000149677 | 293.983 | ||||
Water | 7732-18-5 | 7.5 | 0.00190002 | 3731.85 | ||||
ethonal | 64-17-5 | 2.8 | 0.000251075 | 493.139 | ||||
Ethoxylated alcohol | 68131-39-5 | 10 | 0.00007484 | 146.992 | ||||
formic acid | 64-18-6 | 10 | 0.00007484 | 146.992 | ||||
oleic acid diethanolamide | 93-83-4 | 1 | 0.00101253 | 1988.72 | ||||
Petroleum distillate | 64742-47-8 | 1 | 0.00101253 | 1988.72 | ||||
isoproyl alcohol | 67-63-0 | 5 | 0.00003742 | 73.496 | ||||
ammonium chloride | 12125-02-9 | 30 | 0.0303759 | 59661.6 | ||||
Copolymer of 2-propenamide | 69418-26-4 | 5 | 0.00506264 | 9943.6 | ||||
didecyldimethylammonium chloride | 7173-51-5 | 8 | 0.000714667 | 1403.69 | ||||
Hydrochloric Acid (15%) | Keane | Acidizing | Water | 7732-18-5 | 7.5 | 0.00190002 | 3731.85 | |
Hydrochloric Acid | 7647-01-0 | 15 | 0.00380004 | 7463.7 | ||||
Sand (Proppant) | Keane | Proppant | Crystalline silica: Quartz (SiO2) | 14808-60-7 | 100 | 12.2641 | 24,088,100.0 | |
Scale Inhibitor, KSI-19NW | Keane | Scale Inhibitor | organic phosphonic salts | 15827-60-8 | 15 | 0.00264927 | 5203.46 | |
Water | 7732-18-5 | 95 | 0.0167787 | 32955.3 | ||||
Iron Control, KFEAC-20/30 | Keane | Iron Control | Acetic acid | 64-19-7 | 5 | 0.000105282 | 206.785 | |
Citric acid | 77-92-9 | 30 | 0.000631689 | 1240.71 | ||||
Water | Cabot | Carrier/Base Fluid | Water | 7732-18-5 | 100 | 87.5798 | 172,017,000.0 | |
Biocide, MBC-516 | Keane | Biocide | ethonal | 64-17-5 | 2.8 | 0.000251075 | 493.139 | |
didecyldimethylammonium chloride | 7173-51-5 | 8 | 0.000714667 | 1403.69 | ||||
quaternary ammonium compounds, benzyl-C12-16-alkyldimethyl, chlorides |
68424-85-1 | 5.3 | 0.000476146 | 935.204 | ||||
Glutaral | 111-30-8 | 26.7 | 0.00239418 | 4702.44 | ||||
Water | 7732-18-5 | 56.7 | 0.00508606 | 9989.6 | ||||
Acid Inhibitor, KAI-12 | Keane | Acid Inhibitor | Cinnamaldehyde | 104-55-2 | 10 | 0.00007484 | 146.992 | |
isoproyl alcohol | 67-63-0 | 5 | 0.00003742 | 73.496 | ||||
Tar bases, quinoline derivs., benzyl chloride-quaternized | 72480-70-7 | 10 | 0.00007484 | 146.992 | ||||
Ethoxylated alcohol | 68131-39-5 | 10 | 0.00007484 | 146.992 | ||||
dipropylene gylcol, monomethyl ether | 34590-94-8 | 20 | 0.000149677 | 293.983 | ||||
Ethylene glycol | 107-21-1 | 40 | 0.000299355 | 587.966 | ||||
formic acid | 64-18-6 | 10 | 0.00007484 | 146.992 |
For data sources see[5]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2016 | CABOT OIL & GAS CORP | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2017 | CABOT OIL & GAS CORP | 1,827,106.99 | 138 | 0.00 | 0 | 0.00 | 0 |
2018 | CABOT OIL & GAS CORP | 2,905,300.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2019 | CABOT OIL & GAS CORP | 1,840,450.00 | 365 | 0.00 | 0 | 0.00 | 0 |
For data sources see[6]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2016 | CABOT OIL & GAS CORP | Synthetic Liner Materials | 1.29 Tons | LANDFILL | 101247 |
2017 | CABOT OIL & GAS CORP | Synthetic Liner Materials | 20.57 Tons | LANDFILL | 101247 |
2017 | CABOT OIL & GAS CORP | Other Oil & Gas Wastes | 0.07 Tons | RESIDUAL WASTE PROCESSING FACILITY | 301333 |
2017 | CABOT OIL & GAS CORP | Waste Water Treatment Sludge | 91.34 Tons | REUSE (AT WELL PAD) | |
2017 | CABOT OIL & GAS CORP | Produced Fluid | 10,928.43 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC018 |
2017 | CABOT OIL & GAS CORP | Produced Fluid | 36,975.54 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE004 |
2017 | CABOT OIL & GAS CORP | Unused Fracturing Fluid Waste | 7.64 Tons | LANDFILL | 101247 |
2017 | CABOT OIL & GAS CORP | Produced Fluid | 8,297.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE002 |
2017 | CABOT OIL & GAS CORP | Drill Cuttings | 1,516.15 Tons | LANDFILL | 101247 |
2018 | CABOT OIL & GAS CORP | Produced Fluid | 621.17 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE004 |
2018 | CABOT OIL & GAS CORP | Synthetic Liner Materials | 0.43 Tons | LANDFILL | 101247 |
2018 | CABOT OIL & GAS CORP | Soil Contaminated by Oil & Gas Related Spills | 2.61 Tons | LANDFILL | 100933 |
2018 | CABOT OIL & GAS CORP | Produced Fluid | 7,126.78 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE002 |
2018 | CABOT OIL & GAS CORP | Waste Water Treatment Sludge | 0.32 Tons | REUSE (AT WELL PAD) | |
2018 | CABOT OIL & GAS CORP | Soil Contaminated by Oil & Gas Related Spills | 0.05 Tons | RESIDUAL WASTE PROCESSING FACILITY | 301333 |
2018 | CABOT OIL & GAS CORP | Soil Contaminated by Oil | 0.05 Tons | RESIDUAL WASTE PROCESSING FACILITY | 301333 |
2018 | CABOT OIL & GAS CORP | Soil Contaminated by Oil | 2.61 Tons | LANDFILL | 100933 |
2018 | CABOT OIL & GAS CORP | Produced Fluid | 4,186.49 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC018 |
2019 | CABOT OIL & GAS CORP | Produced Fluid | 999.06 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE002 |
2019 | CABOT OIL & GAS CORP | Produced Fluid | 5,580.78 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE004 |
2019 | CABOT OIL & GAS CORP | Synthetic Liner Materials | 0.06 Tons | LANDFILL | 101247 |
For data sources see[7]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2493837 | Primary Facility | 2016-06-08 | Preoperation Inspection | No Violations Noted | On 6/8/16, the Department was on site at the COG Romeika, J. Pad 1 to conduct a Preoperational Inspection. The well permits that have been issued for this site are the Romeika 1H (115-22077), 2H (115-22078), 4H (115-22089), 6H (115-22090), and the 8H (115-22091). All perimeter BMP’s in place. Good temporary vegetative cover exists. E & S inspections up-to-date. No well drilling has occurred on the pad. Overall, the site looks good. No violations noted. |
2525593 | Primary Facility | 2016-10-05 | Drilling/Alteration | No Violations Noted | At time of inspection, arrived on site at 8:55a.m. for a new spud inspection, I met with company man James Cheek, United Drilling was on site to drill the holes and run the conductor pipe. There were two rigs running, one rig was drilling the mouse holes and the other one was drilling the hole for the conductor pipe on the 4H. The rig on the 4H was at a depth of 95' and will drill to a depth of 149', then run and cement the conductor pipe into place. I took a walk around the location and there were no obvious concerns noticed.
I left the site at 9:30a.m. |
2574680 | Primary Facility | 2017-03-22 | Drilling/Alteration | No Violations Noted | At time of inspection, arrived on site at 11:40a.m.
I met with company man Tony Ketterling. Nabors Rig X36 was on site and drilling the lateral section of the well. I took a walk around the location and there were no obvious concerns noticed. Depth at time of inspection was 6,226' Projected TD for the well is 17,100' I left the site at 12:45p.m. |
2617077 | Primary Facility | 2017-07-18 | Routine/Complete Inspection | No Violations Noted | At time of inspection, arrived on site at 12:45p.m.
I met with company men Larry Fulmer and Mike Vollmer. Keanes was on site to stimulate the 1H, 2H, 4H, 6H, and 8H wells. They were shut down to have a brace repaired on the frac missile. The 1H had 33 stages out of 51 completed. The 2H had 30 stages out of 41 completed. The 4H had 25 stages out of 48 completed. The 6H had 32 stages out of 65 completed. The 8H had 33 stages out of 69 completed. I took a walk around the location and there were no obvious concerns noticed. I left the site at 13:35p.m. |
2643698 | Primary Facility | 2017-10-04 | Routine/Complete Inspection | No Violations Noted | At time of inspection.
The well was recently stimulated and put into production. The well tag is on the well and correct. All the annulus vent pipes are connected together and going to the same tank. The production fluid is going into a 500bbl flow back tank that is on containment and the containment appears to be in good condition. The 500bbl frac tanks are still on site and on containment. They are empty and the man holes are open. The containment appears to be in good condition. There were no obvious concerns noticed. There were no violations noted. |
2682178 | Primary Facility | 2018-01-08 | Routine/Complete Inspection | No Violations Noted | Today's inspection is being conducted as a routine inspection. All 5 wells, the 1H, 2H, 4H, 6H, and the 8H appear to be in production. Site appears to be stable. No spills detected. No violations noted. |
2692634 | Primary Facility | 2018-02-08 | Routine/Complete Inspection | No Violations Noted | Inspection conducted as a routine inspection. No E&S violations noted. No violations noted. |
2723099 | Primary Facility | 2018-04-11 | Incident- Response to Accident or Event | No Violations Noted | Gene Rickard, DEP O&G WQS and I arrived at the site at 11:14 in response to a reported spill of (5-7) gallons of production fluid to the pad surface. As we arrived there was no activity or personnel at the site. The weather conditions are mostly cloudy, cold and breezy with temperatures in the 30's. All wells on the pad are in production. We observed a Diaz container covered with a liner made of plastic material and a (55) gallon capacity drum labeled "Romeika 4/11/18 Brine Gravel GDS" on the pad surface near the production fluid and storm water tanks containment structure. In addition to observing the containers, we were able to determine that the location of the area on the pad surface remediated due to the spill was near the production fluid and storm water tanks containment structure. I conducted specific conductance (conductivity) screening of damp pad surface pad material just outside of the perimeter of the excavation of the impacted area near yellow sand bags, near the center of the excavation, storm |
2726622 | Primary Facility | 2018-04-12 | Follow-up Inspection | No Violations Noted | I arrived at the site at 12:57. Rain was falling with temperatures around 50 degrees Fahrenheit. Steve Catalfamo, Professional Geologist and Senior Environmental Health and Safety Specialist of Cabot Oil and Gas accompanied me during the inspection. The intent of the follow up inspection was to conduct field soil specific conductance (conductivity) screening in the general area on the pad surface where the production fluid spill occurred on 4/9/18. During an inspection at the site on 4/11/18, I recorded (3.02) millisiemens/cm conductivity in damp soil just outside the section of the pad surface remediated as a result of the spill. It had appeared as if the spill had not been adequately remediated. Conductivity was in the range of (0.5 -1.0) millisiemens/cm on 4/12/18 in the location where I recorded (3.02) milllisiemens/cm. The impacted area was backfilled with clean fill yesterday according to Mr. Catalfamo. Conductivity readings on my meter where less than (100) microsiemens/cm in the area backfilled. See |
2739149 | Primary Facility | 2018-06-04 | Administrative/File Review | No Violations Noted | This administration inspection report has been created to document a spill of an estimated (5-7) gallons of production fluid to the pad surface which occurred on 4/9/18 as documented in the Department's 4/11/18 and 4/12/18 inspection reports, Inspection ID #'s 2721248 and 2725656. Cabot submitted a Remediation Summary Report prepared by Resource Environmental of Montrose, PA to the Department on 5-23-18. The report contains a description of the incident, summary of remediation and characterization activities, waste disposal information, a site location map, a site map displaying the perimeter of the excavation, final soil conductivity screenings on 4/10/18, additional soil conductivity screenings on 4/13/18 and disposal documents of gravel impacted with produced fluids transported to Waste Recovery Solutions in Myerstown, PA.
The Description of the incident states the following information." At approximately 20:30 hours on April 9, 2018, a GasSearch Drilling Services Corporation (GDS) residual waste vacu |
2749804 | Primary Facility | 2018-07-09 | Routine/Complete Inspection | No Violations Noted | At time of inspection.
The well was in production. There was water 7.5' below grade in the cellar with no bubbling noticed and there was no gas detected in the remainder of the cellar. The (20x13), (13x9) and (9x5) annuli vent pipes were connected together and going to the same poly vent tank. There was gas detected at the poly vent tank. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted. |
2851344 | Primary Facility | 2019-03-11 | Routine/Complete Inspection | No Violations Noted | At time of inspection.
The well was in production. There was water and ice 7.5' below grade in the cellar with no bubbling noticed and there was no gas detected in the remainder of the cellar. The (20x13), (13x9) and (9x5) annuli vent pipes were connected together and going to the same poly vent tank. There was gas detected at the poly vent tank with a MSA Altair 5X multi gas detector that was calibrated on 3/4/19. There was an empty 500bbl tank on containment and the containment appeared to be in good condition. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted. |
For data sources see[8]