If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-115-21701 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.795297,"lon":-75.568369,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Susquehanna | |
Municipality: Gibson Township | |
Operator Name: CABOT OIL & GAS CORP | |
Well Pad ID: 150998 | |
Farm/Lease Name: PLONSKI I 4 | |
License Status: | |
Spud Date: | |
Permit Date: 2014-03-03 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: No | |
Latitude: 41.795297 | |
Longitude: -75.568369 |
Date | Event |
---|---|
2014-03-03 | New Permit Application |
2014-06-12 | Performed Spud Operation |
2014-09-14 | Drilling Completion |
2014-10-20 | Perforation |
2014-11-03 | Performed Stimulation |
2015-03-17 | DEVIATED |
For data sources see[4]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2014-11-02 | 2014-11-20 | 7,138 | 10,789,200 | 0 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | Greenhib 679 | Chemplex | Friction Reducer | Proprietary | Proprietary | 35 | 0.00841708 | 8649.16 |
Glycerine | 56-81-5 | 20 | 0.00480976 | 4942.38 | ||||
Sand (Proppant) | TSS | Proppant | Silica Substrate | 14808-60-7 | 100 | 11.1083 | 11,414,600.0 | |
Hydrochloric Acid (15%) | Reagent | Acidizing | Hydrochloric Acid | 7647-01-0 | 15 | 0.0879192 | 90343.4 | |
Water | Select | Carrier/Base Fluid | Water | 7732-18-5 | 100 | 88.1679 | 90,598,900.0 | |
Plexbreak 145 | Chemplex | Non-Emulsifier | Methyl Alcohol | 67-56-1 | 15 | 0.00009355 | 96.134 | |
Diethanolamine | 111-42-2 | 3 | 0.00001871 | 19.227 | ||||
Cocamide Based Surfactant | Proprietary | 10 | 0.00006237 | 64.09 | ||||
2-Butoxyethanol | 111-76-2 | 15 | 0.00009355 | 96.134 | ||||
Chemplex 4-N-1 | Chemplex | Combination/Iron Control | Alcohol Ethoxylate Surfactants | Proprietary | 2 | 0.00002119 | 21.769 | |
n-olefins | Proprietary | 1 | 0.00001059 | 10.885 | ||||
Cocamide Diethanolamine Salt | 68603-42-9 | 2 | 0.00002119 | 21.769 | ||||
thiourea-formaldehyde copolymer | 68527-49-1 | 2 | 0.00002119 | 21.769 | ||||
Propargyl Alcohol | 107-19-7 | 1 | 0.00001059 | 10.885 | ||||
Diethanolamine | 111-42-2 | 2 | 0.00002119 | 21.769 | ||||
Methyl Alcohol | 67-56-1 | 10 | 0.000105925 | 108.846 | ||||
2-Ethylhexanol | 104-76-7 | 10 | 0.000105925 | 108.846 | ||||
Acetic Acid | 64-19-7 | 85 | 0.000900365 | 925.19 | ||||
Plexhib 256 | Chemplex | Acid Inhibitor | C-14 to C-16 Alpha Olefins | 64743-02-8 | 5 | 0.00002933 | 30.142 | |
Methyl Alcohol | 67-56-1 | 60 | 0.000352 | 361.706 | ||||
Polyethoxylated Alcohol Surfactant | 68951-67-7 | 30 | 0.000176 | 180.853 | ||||
Thiourea/Formaldehyde Copolymer | 68527-49-1 | 30 | 0.000176 | 180.853 | ||||
Propargyl Alcohol | 107-19-7 | 10 | 0.00005867 | 60.284 | ||||
Ferriplex 40 | Chemplex | Iron Control | Sodium Hydroxide | 1310-73-2 | 1 | 0.00002111 | 21.697 | |
Sodium Sulfate Anhydrous | 7757-82-6 | 2 | 0.00004223 | 43.394 | ||||
Trisodium Nitrilotriacetate | 5064-31-3 | 40 | 0.000844593 | 867.88 | ||||
Plexslick 957 | Chemplex | Friction Reducer | Nonionic Surfactants | Proprietary | 1.5 | 0.00130995 | 1346.07 | |
Ammonium Chloride | 12125-02-9 | 5 | 0.0043665 | 4486.9 | ||||
Paraffinic, Naphtehenic Solvent | 64742-47-8 | 30 | 0.026199 | 26921.4 | ||||
Poly (acrylamide-co-acrylic acid), partial sodium salt | 62649-23-4 | 35 | 0.0305655 | 31408.3 | ||||
Plexcide 15G | Chemplex | Biocide | Ethanol | 64-17-5 | 3 | 0.000657954 | 676.095 | |
Alkyl Dimethyl Benzyl Ammonium Chloride | 68424-85-1 | 3 | 0.000657954 | 676.095 | ||||
Glutaraldehyde | 111-30-8 | 14 | 0.00307045 | 3155.11 | ||||
Didecyl Dimethyl Ammonium Chloride | 7173-51-5 | 3 | 0.000657954 | 676.095 |
For data sources see[5]
Stimulation Date | Phase Number | Chemical Agent | Volume (gal) | Treating Pressure (psi) | Breakdown Pressure (psi) |
---|---|---|---|---|---|
2014-11-03 | 0 | 0 | 0 |
For data sources see[6]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2014 | CABOT OIL & GAS CORP | 172,575.96 | 25 | 0.00 | 0 | 0.00 | 0 |
2015 | CABOT OIL & GAS CORP | 1,985,232.26 | 365 | 0.00 | 0 | 0.00 | 0 |
2016 | CABOT OIL & GAS CORP | 1,278,042.42 | 366 | 0.00 | 0 | 0.00 | 0 |
2017 | CABOT OIL & GAS CORP | 813,859.47 | 358 | 0.00 | 0 | 0.00 | 0 |
2018 | CABOT OIL & GAS CORP | 704,675.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2019 | CABOT OIL & GAS CORP | 590,218.00 | 365 | 0.00 | 0 | 0.00 | 0 |
For data sources see[7]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2014 | CABOT OIL & GAS CORP | Fracing Fluid Waste | 1,011.66 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE001 |
2014 | CABOT OIL & GAS CORP | Fracturing Fluid Waste | 16.39 Tons | LANDFILL | UT2300249 |
2014 | CABOT OIL & GAS CORP | Fracing Fluid Waste | 13,039.37 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE002 |
2014 | CABOT OIL & GAS CORP | Fracing Fluid Waste | 6,046.16 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2014 | CABOT OIL & GAS CORP | Drill Cuttings | 1,508.65 Tons | LANDFILL | 101247 |
2014 | CABOT OIL & GAS CORP | Drilling Fluid Waste | 44.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR119 |
2015 | CABOT OIL & GAS CORP | Fracing Fluid Waste | 683.24 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE002 |
2015 | CABOT OIL & GAS CORP | Produced Fluid | 10,718.10 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE002 |
2015 | CABOT OIL & GAS CORP | Produced Fluid | 638.19 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE001 |
2016 | CABOT OIL & GAS CORP | Produced Fluid | 47.25 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NE004 |
2016 | CABOT OIL & GAS CORP | Waste Water Treatment Sludge | 1.00 Tons | LANDFILL | 301358 |
2016 | CABOT OIL & GAS CORP | Produced Fluid | 1,208.75 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE002 |
2016 | CABOT OIL & GAS CORP | Produced Fluid | 445.76 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE002 |
2017 | CABOT OIL & GAS CORP | Produced Fluid | 62.30 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE002 |
2017 | CABOT OIL & GAS CORP | Produced Fluid | 12.29 Bbl | REUSE (AT WELL PAD) | |
2017 | CABOT OIL & GAS CORP | Produced Fluid | 317.69 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE004 |
2017 | CABOT OIL & GAS CORP | Synthetic Liner Materials | 0.64 Tons | LANDFILL | 101247 |
2017 | CABOT OIL & GAS CORP | Produced Fluid | 391.38 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC018 |
2018 | CABOT OIL & GAS CORP | Produced Fluid | 28.05 Bbl | REUSE (AT WELL PAD) | |
2018 | CABOT OIL & GAS CORP | Produced Fluid | 384.87 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE002 |
2018 | CABOT OIL & GAS CORP | Produced Fluid | 73.30 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE004 |
2018 | CABOT OIL & GAS CORP | Produced Fluid | 192.10 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC018 |
2019 | CABOT OIL & GAS CORP | Produced Fluid | 56.16 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE002 |
2019 | CABOT OIL & GAS CORP | Produced Fluid | 469.25 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE004 |
For data sources see[8]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2278002 | Primary Facility | 2014-06-11 | Preoperation Inspection | No Violations Noted | The Department was on site at the Cabot Well Site and Tank Pad to conduct a Preoperational Inspection. The well permits that have been issued for this pad are the Plonski I 1H (115-21698), 2H (115-21699), 3H (115-21700), and the 4H (115-21701). All perimeter BMP’s in place to include red lined additions. Pad is approximately 98% complete. No violations noted. |
2278015 | Primary Facility | 2014-05-28 | Routine/Complete Inspection | No Violations Noted | The Department conducted an inspection of the Cabot Plonski I well pad on 5/28/14. The site is approximately 50% complete. Both sediment traps are in place. Perimeter controls appear to be installed properly, but site is currently not developed enough to determine if controls installed in proper locations. No violations noted. This inspection does not qualify as a preoperational inspection. |
2282602 | Primary Facility | 2014-06-25 | Routine/Complete Inspection | No Violations Noted | The following wells which have been spud on this pad are the Plonski I 1H (115-21698), 2H (115-21699), 3H (115-21700), and the 4H (115-21701). A crew is on-site installing a liner for a drill rig. |
2284281 | Primary Facility | 2014-06-17 | Drilling/Alteration | No Violations Noted | UDI spudder rig on location |
2294088 | Primary Facility | 2014-07-21 | Follow-up Inspection | No Violations Noted | Arrived at the site at 12:25 to conduct a Follow-up inspection in relation to a hydraulic fluid spill that occurred on 6/24/14. It was reported that an estimated (20) gallons of hydraulic fluid fluid was spilled to the pad surface. The spill has been reported as cleaned up. The Deparmtent is awaiting a spill report from Cabot. |
2298776 | Primary Facility | 2014-08-21 | Drilling/Alteration | No Violations Noted | |
2311217 | Primary Facility | 2014-10-09 | Administrative/File Review | No Violations Noted | On 6/24/14, Cabot Oil and Gas reported a 20 gallon release of hydraulic fluid to the ground due to the failure of a master cylinder of a dump truck. Cabot emailed an electronic copy of their remediation summary report for this spill. Attached is a copy of that report. After a review of the report, the Department concludes that the spill response was adequate and that no further action is required by the Department. VIOIC associated with Inspection Record # 2282584. |
2421131 | Primary Facility | 2015-10-23 | Routine/Complete Inspection | No Violations Noted | The Department was on site to perform a routine complete inspection at the Plonski I Well Pad (ESG13-115-0085). The wells associated with this site are: |
2453890 | Primary Facility | 2016-02-23 | Routine/Complete Inspection | No Violations Noted | On 2/23/16, the Department collected water samples from a nearby complainant. The samples were clear with no effervescence observed. The nearest gas well activity/development to the complainant’s water well are the following 3 Cabot well pads:
Reilly J Pad This is the closest pad and is located approximately 2900’ away. There is only one well on this pad, the 3H which is in production. The well was spud on 8/10/2012, drilling was completed on 10/12/2012, and stimulation was completed on 1/10/2013. Plonski I Pad This pad is located approximately 3500’ away. There are 5 producing wells on this pad. All the wells were spud in June, 2014 with stimulation completed for all three wells in November, 2014. Stellitano A Pad This pad is located approximately 4000’ away. There are 8 drilled wells on this pad that are currently being stimulated. There are no violations associated with this complaint inspection. |
2477053 | Primary Facility | 2016-04-21 | Routine/Complete Inspection | No Violations Noted | |
2498556 | Primary Facility | 2016-07-05 | Routine/Complete Inspection | No Violations Noted | |
2579199 | Primary Facility | 2017-04-03 | Routine/Complete Inspection | No Violations Noted | At time of inspection, arrived on site at 13:25p.m.
The cellar was about three quarters full of water with no bubbling noticed. The (13x9) annulus vent pipe was open and venting into a small plastic tank, the (9x5) annulus vent pipe was open and venting into a small plastic tank. There was 634psi on the production casing. I took a walk around the location and there were no obvious concerns noticed. I left the site at 14:05p.m. |
2618201 | Primary Facility | 2017-07-24 | Routine/Complete Inspection | No Violations Noted | Today' inspection, 7/20/17 is being conducted as a routine inspection. A work over rig is on-site working. The entire site is stable. Rig appears to have good containment. All slopes stable, no violations noted. No photos attached due to a technical glitch. |
2684108 | Primary Facility | 2018-01-18 | Routine/Complete Inspection | No Violations Noted | At time of inspection.
The cellar was full of ice and was unable to check for gas. The (20x13) annulus was below ice and was unable to check for gas. The (13x9) and (9x5) annuli vent pipes were connected together and venting to the same tank. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted. |
2759479 | Primary Facility | 2018-08-01 | Routine/Complete Inspection | No Violations Noted | Today's inspection was conducted as a routine inspection. No E&S issues identified. No violations noted. |
2782105 | Primary Facility | 2018-09-25 | Routine/Complete Inspection | No Violations Noted | Today's inspection has been conducted as a routine inspection. Site has good site stabilization. No E&S issues identified. No violations noted. |
2784485 | Primary Facility | 2018-10-04 | Routine/Complete Inspection | No Violations Noted | At time of inspection.
The well was in production. There was water 1' below grade in the cellar and there was no bubbling noticed. The (13x9) and (9x5) annuli vent pipes were connected together and going to the same poly vent tank. There was gas detected at the poly vent tank. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted. |
2800542 | Primary Facility | 2018-11-06 | Routine/Complete Inspection | No Violations Noted | This inspection was conducted to confirm Cabot's assessment that the project meets the minimum requirements for permit termination. The Department’s determination is that the site meets the requirements for permit termination. I recommend the NOT be approved. |
For data sources see[9]