X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-115-21701

Well Details

Well ID: 37-115-21701
Loading map...
Country: United States
State: Pennsylvania
County: Susquehanna
Municipality: Gibson Township
Operator Name: CABOT OIL & GAS CORP
Well Pad ID: 150998
Farm/Lease Name: PLONSKI I 4
License Status:
Spud Date:
Permit Date: 2014-03-03
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.795297
Longitude: -75.568369

For data sources see[1][2][3]

Well History

Date Event
2014-03-03 New Permit Application
2014-06-12 Performed Spud Operation
2014-09-14 Drilling Completion
2014-10-20 Perforation
2014-11-03 Performed Stimulation
2015-03-17 DEVIATED

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2014-11-02 2014-11-20 7,138 10,789,200 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Greenhib 679 Chemplex Friction Reducer Proprietary Proprietary 35 0.00841708 8649.16
Glycerine 56-81-5 20 0.00480976 4942.38
Sand (Proppant) TSS Proppant Silica Substrate 14808-60-7 100 11.1083 11,414,600.0
Hydrochloric Acid (15%) Reagent Acidizing Hydrochloric Acid 7647-01-0 15 0.0879192 90343.4
Water Select Carrier/Base Fluid Water 7732-18-5 100 88.1679 90,598,900.0
Plexbreak 145 Chemplex Non-Emulsifier Methyl Alcohol 67-56-1 15 0.00009355 96.134
Diethanolamine 111-42-2 3 0.00001871 19.227
Cocamide Based Surfactant Proprietary 10 0.00006237 64.09
2-Butoxyethanol 111-76-2 15 0.00009355 96.134
Chemplex 4-N-1 Chemplex Combination/Iron Control Alcohol Ethoxylate Surfactants Proprietary 2 0.00002119 21.769
n-olefins Proprietary 1 0.00001059 10.885
Cocamide Diethanolamine Salt 68603-42-9 2 0.00002119 21.769
thiourea-formaldehyde copolymer 68527-49-1 2 0.00002119 21.769
Propargyl Alcohol 107-19-7 1 0.00001059 10.885
Diethanolamine 111-42-2 2 0.00002119 21.769
Methyl Alcohol 67-56-1 10 0.000105925 108.846
2-Ethylhexanol 104-76-7 10 0.000105925 108.846
Acetic Acid 64-19-7 85 0.000900365 925.19
Plexhib 256 Chemplex Acid Inhibitor C-14 to C-16 Alpha Olefins 64743-02-8 5 0.00002933 30.142
Methyl Alcohol 67-56-1 60 0.000352 361.706
Polyethoxylated Alcohol Surfactant 68951-67-7 30 0.000176 180.853
Thiourea/Formaldehyde Copolymer 68527-49-1 30 0.000176 180.853
Propargyl Alcohol 107-19-7 10 0.00005867 60.284
Ferriplex 40 Chemplex Iron Control Sodium Hydroxide 1310-73-2 1 0.00002111 21.697
Sodium Sulfate Anhydrous 7757-82-6 2 0.00004223 43.394
Trisodium Nitrilotriacetate 5064-31-3 40 0.000844593 867.88
Plexslick 957 Chemplex Friction Reducer Nonionic Surfactants Proprietary 1.5 0.00130995 1346.07
Ammonium Chloride 12125-02-9 5 0.0043665 4486.9
Paraffinic, Naphtehenic Solvent 64742-47-8 30 0.026199 26921.4
Poly (acrylamide-co-acrylic acid), partial sodium salt 62649-23-4 35 0.0305655 31408.3
Plexcide 15G Chemplex Biocide Ethanol 64-17-5 3 0.000657954 676.095
Alkyl Dimethyl Benzyl Ammonium Chloride 68424-85-1 3 0.000657954 676.095
Glutaraldehyde 111-30-8 14 0.00307045 3155.11
Didecyl Dimethyl Ammonium Chloride 7173-51-5 3 0.000657954 676.095

For data sources see[5]

Stimulation Data

Stimulation Date Phase Number Chemical Agent Volume (gal) Treating Pressure (psi) Breakdown Pressure (psi)
2014-11-03 0 0 0

For data sources see[6]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2014 CABOT OIL & GAS CORP 172,575.96 25 0.00 0 0.00 0
2015 CABOT OIL & GAS CORP 1,985,232.26 365 0.00 0 0.00 0
2016 CABOT OIL & GAS CORP 1,278,042.42 366 0.00 0 0.00 0
2017 CABOT OIL & GAS CORP 813,859.47 358 0.00 0 0.00 0
2018 CABOT OIL & GAS CORP 704,675.00 365 0.00 0 0.00 0
2019 CABOT OIL & GAS CORP 590,218.00 365 0.00 0 0.00 0

For data sources see[7]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2014 CABOT OIL & GAS CORP Fracing Fluid Waste 1,011.66 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE001
2014 CABOT OIL & GAS CORP Fracturing Fluid Waste 16.39 Tons LANDFILL UT2300249
2014 CABOT OIL & GAS CORP Fracing Fluid Waste 13,039.37 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2014 CABOT OIL & GAS CORP Fracing Fluid Waste 6,046.16 Bbl REUSE OTHER THAN ROAD SPREADING
2014 CABOT OIL & GAS CORP Drill Cuttings 1,508.65 Tons LANDFILL 101247
2014 CABOT OIL & GAS CORP Drilling Fluid Waste 44.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR119
2015 CABOT OIL & GAS CORP Fracing Fluid Waste 683.24 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2015 CABOT OIL & GAS CORP Produced Fluid 10,718.10 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2015 CABOT OIL & GAS CORP Produced Fluid 638.19 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE001
2016 CABOT OIL & GAS CORP Produced Fluid 47.25 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NE004
2016 CABOT OIL & GAS CORP Waste Water Treatment Sludge 1.00 Tons LANDFILL 301358
2016 CABOT OIL & GAS CORP Produced Fluid 1,208.75 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2016 CABOT OIL & GAS CORP Produced Fluid 445.76 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2017 CABOT OIL & GAS CORP Produced Fluid 62.30 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2017 CABOT OIL & GAS CORP Produced Fluid 12.29 Bbl REUSE (AT WELL PAD)
2017 CABOT OIL & GAS CORP Produced Fluid 317.69 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE004
2017 CABOT OIL & GAS CORP Synthetic Liner Materials 0.64 Tons LANDFILL 101247
2017 CABOT OIL & GAS CORP Produced Fluid 391.38 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC018
2018 CABOT OIL & GAS CORP Produced Fluid 28.05 Bbl REUSE (AT WELL PAD)
2018 CABOT OIL & GAS CORP Produced Fluid 384.87 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2018 CABOT OIL & GAS CORP Produced Fluid 73.30 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE004
2018 CABOT OIL & GAS CORP Produced Fluid 192.10 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC018
2019 CABOT OIL & GAS CORP Produced Fluid 56.16 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2019 CABOT OIL & GAS CORP Produced Fluid 469.25 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE004

For data sources see[8]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2278002 Primary Facility 2014-06-11 Preoperation Inspection No Violations Noted The Department was on site at the Cabot Well Site and Tank Pad to conduct a Preoperational Inspection. The well permits that have been issued for this pad are the Plonski I 1H (115-21698), 2H (115-21699), 3H (115-21700), and the 4H (115-21701). All perimeter BMP’s in place to include red lined additions. Pad is approximately 98% complete. No violations noted.
2278015 Primary Facility 2014-05-28 Routine/Complete Inspection No Violations Noted The Department conducted an inspection of the Cabot Plonski I well pad on 5/28/14. The site is approximately 50% complete. Both sediment traps are in place. Perimeter controls appear to be installed properly, but site is currently not developed enough to determine if controls installed in proper locations. No violations noted. This inspection does not qualify as a preoperational inspection.
2282602 Primary Facility 2014-06-25 Routine/Complete Inspection No Violations Noted The following wells which have been spud on this pad are the Plonski I 1H (115-21698), 2H (115-21699), 3H (115-21700), and the 4H (115-21701). A crew is on-site installing a liner for a drill rig.
2284281 Primary Facility 2014-06-17 Drilling/Alteration No Violations Noted UDI spudder rig on location
2294088 Primary Facility 2014-07-21 Follow-up Inspection No Violations Noted Arrived at the site at 12:25 to conduct a Follow-up inspection in relation to a hydraulic fluid spill that occurred on 6/24/14. It was reported that an estimated (20) gallons of hydraulic fluid fluid was spilled to the pad surface. The spill has been reported as cleaned up. The Deparmtent is awaiting a spill report from Cabot.
2298776 Primary Facility 2014-08-21 Drilling/Alteration No Violations Noted
2311217 Primary Facility 2014-10-09 Administrative/File Review No Violations Noted On 6/24/14, Cabot Oil and Gas reported a 20 gallon release of hydraulic fluid to the ground due to the failure of a master cylinder of a dump truck. Cabot emailed an electronic copy of their remediation summary report for this spill. Attached is a copy of that report. After a review of the report, the Department concludes that the spill response was adequate and that no further action is required by the Department. VIOIC associated with Inspection Record # 2282584.
2421131 Primary Facility 2015-10-23 Routine/Complete Inspection No Violations Noted The Department was on site to perform a routine complete inspection at the Plonski I Well Pad (ESG13-115-0085). The wells associated with this site are:
2453890 Primary Facility 2016-02-23 Routine/Complete Inspection No Violations Noted On 2/23/16, the Department collected water samples from a nearby complainant. The samples were clear with no effervescence observed. The nearest gas well activity/development to the complainant’s water well are the following 3 Cabot well pads:

Reilly J Pad This is the closest pad and is located approximately 2900’ away. There is only one well on this pad, the 3H which is in production. The well was spud on 8/10/2012, drilling was completed on 10/12/2012, and stimulation was completed on 1/10/2013.

Plonski I Pad This pad is located approximately 3500’ away. There are 5 producing wells on this pad. All the wells were spud in June, 2014 with stimulation completed for all three wells in November, 2014.

Stellitano A Pad This pad is located approximately 4000’ away. There are 8 drilled wells on this pad that are currently being stimulated.

There are no violations associated with this complaint inspection.

2477053 Primary Facility 2016-04-21 Routine/Complete Inspection No Violations Noted
2498556 Primary Facility 2016-07-05 Routine/Complete Inspection No Violations Noted
2579199 Primary Facility 2017-04-03 Routine/Complete Inspection No Violations Noted At time of inspection, arrived on site at 13:25p.m.

The cellar was about three quarters full of water with no bubbling noticed. The (13x9) annulus vent pipe was open and venting into a small plastic tank, the (9x5) annulus vent pipe was open and venting into a small plastic tank. There was 634psi on the production casing. I took a walk around the location and there were no obvious concerns noticed. I left the site at 14:05p.m.

2618201 Primary Facility 2017-07-24 Routine/Complete Inspection No Violations Noted Today' inspection, 7/20/17 is being conducted as a routine inspection. A work over rig is on-site working. The entire site is stable. Rig appears to have good containment. All slopes stable, no violations noted. No photos attached due to a technical glitch.
2684108 Primary Facility 2018-01-18 Routine/Complete Inspection No Violations Noted At time of inspection.

The cellar was full of ice and was unable to check for gas. The (20x13) annulus was below ice and was unable to check for gas. The (13x9) and (9x5) annuli vent pipes were connected together and venting to the same tank. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted.

2759479 Primary Facility 2018-08-01 Routine/Complete Inspection No Violations Noted Today's inspection was conducted as a routine inspection. No E&S issues identified. No violations noted.
2782105 Primary Facility 2018-09-25 Routine/Complete Inspection No Violations Noted Today's inspection has been conducted as a routine inspection. Site has good site stabilization. No E&S issues identified. No violations noted.
2784485 Primary Facility 2018-10-04 Routine/Complete Inspection No Violations Noted At time of inspection.

The well was in production. There was water 1' below grade in the cellar and there was no bubbling noticed. The (13x9) and (9x5) annuli vent pipes were connected together and going to the same poly vent tank. There was gas detected at the poly vent tank. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted.

2800542 Primary Facility 2018-11-06 Routine/Complete Inspection No Violations Noted This inspection was conducted to confirm Cabot's assessment that the project meets the minimum requirements for permit termination. The Department’s determination is that the site meets the requirements for permit termination. I recommend the NOT be approved.

For data sources see[9]