X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-115-21689

Well Details

Well ID: 37-115-21689
Loading map...
Country: United States
State: Pennsylvania
County: Susquehanna
Municipality: Jessup Township
Operator Name: CABOT OIL & GAS CORP
Well Pad ID: 150978
Farm/Lease Name: MILLARD K 8
License Status:
Spud Date:
Permit Date: 2014-02-27
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.837689
Longitude: -75.969736

For data sources see[1][2][3]

Well History

Date Event
2014-02-27 New Permit Application
2014-03-27 Performed Spud Operation
2014-06-16 Drilling Completion
2014-06-24 Perforation
2014-07-02 Performed Stimulation
2015-01-12 DEVIATED

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2014-07-01 2014-07-11 6,392 9,854,670 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Plexbreak 145 Chemplex Non-Emulsifier Cocamide Based Surfactant Proprietary 10 0.00009244 86.521
Diethanolamine 111-42-2 3 0.00002773 25.956
2-Butoxyethanol 111-76-2 15 0.000138667 129.781
Methyl Alcohol 67-56-1 15 0.000138667 129.781
Plexhib 256 Chemplex Acid Inhibitor Thiourea/Formaldehyde Copolymer 68527-49-1 30 0.000248445 232.525
Propargyl Alcohol 107-19-7 10 0.00008281 77.508
C-14 to C-16 Alpha Olefins 64743-02-8 5 0.00004141 38.754
Polyethoxylated Alcohol Surfactant 68951-67-7 30 0.000248445 232.525
Methyl Alcohol 67-56-1 60 0.00049689 465.05
Plexslick 957 Chemplex Friction Reducer Ammonium Chloride 12125-02-9 5 0.0045966 4302.06
Nonionic Surfactants Proprietary 1.5 0.00137898 1290.62
Poly (acrylamide-co-acrylic acid), partial sodium salt 62649-23-4 35 0.0321762 30114.5
Paraffinic, Naphtehenic Solvent 64742-47-8 30 0.0275796 25812.4
Hydrochloric Acid (15%) Reagent Acidizing Hydrochloric Acid 7647-01-0 15 0.0772779 72326.1
Water Select Carrier/Base Fluid Water 7732-18-5 100 88.3599 82,698,000.0
Sand (Proppant) TSS Proppant Silica Substrate 14808-60-7 100 10.9814 10,277,800.0
Greenhib 679 Chemplex Friction Reducer Glycerine 56-81-5 20 0.00487132 4559.17
Proprietary Proprietary 35 0.0085248 7978.55
Plexcide 15G Chemplex Biocide Ethanol 64-17-5 3 0.000669862 626.939
Alkyl Dimethyl Benzyl Ammonium Chloride 68424-85-1 3 0.000669862 626.939
Didecyl Dimethyl Ammonium Chloride 7173-51-5 3 0.000669862 626.939
Glutaraldehyde 111-30-8 14 0.00312602 2925.72
Ferriplex 40 Chemplex Iron Control Trisodium Nitrilotriacetate 5064-31-3 40 0.00125185 1171.64
Sodium Hydroxide 1310-73-2 1 0.00003130 29.291
Sodium Sulfate Anhydrous 7757-82-6 2 0.00006259 58.582

For data sources see[5]

Stimulation Data

Stimulation Date Phase Number Chemical Agent Volume (gal) Treating Pressure (psi) Breakdown Pressure (psi)
2014-07-02 0 0 0

For data sources see[6]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2014 CABOT OIL & GAS CORP 1,827,545.44 159 0.00 0 0.00 0
2015 CABOT OIL & GAS CORP 2,613,088.91 365 0.00 0 0.00 0
2016 CABOT OIL & GAS CORP 2,252,564.77 366 0.00 0 0.00 0
2017 CABOT OIL & GAS CORP 1,707,877.62 365 0.00 0 0.00 0
2018 CABOT OIL & GAS CORP 1,299,415.00 365 0.00 0 0.00 0
2019 CABOT OIL & GAS CORP 1,122,490.00 365 0.00 0 0.00 0

For data sources see[7]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2014 CABOT OIL & GAS CORP Produced Fluid 8,029.36 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2014 CABOT OIL & GAS CORP Fracing Fluid Waste 6,858.24 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE001
2014 CABOT OIL & GAS CORP Drill Cuttings 75.72 Tons LANDFILL THR029
2014 CABOT OIL & GAS CORP Drill Cuttings 1,399.04 Tons LANDFILL 101247
2014 CABOT OIL & GAS CORP Fracing Fluid Waste 12,688.50 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2014 CABOT OIL & GAS CORP Drilling Fluid Waste 10.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE001
2014 CABOT OIL & GAS CORP Drilling Fluid Waste 144.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR119
2015 CABOT OIL & GAS CORP Produced Fluid 2,946.69 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2016 CABOT OIL & GAS CORP Produced Fluid 263.54 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2016 CABOT OIL & GAS CORP Produced Fluid 428.53 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC018
2016 CABOT OIL & GAS CORP Produced Fluid 795.11 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2017 CABOT OIL & GAS CORP Produced Fluid 856.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC018
2017 CABOT OIL & GAS CORP Produced Fluid 78.84 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2018 CABOT OIL & GAS CORP Produced Fluid 13.25 Bbl REUSE (AT WELL PAD)
2018 CABOT OIL & GAS CORP Produced Fluid 359.22 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2018 CABOT OIL & GAS CORP Produced Fluid 302.94 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC018
2019 CABOT OIL & GAS CORP Produced Fluid 654.52 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002

For data sources see[8]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2264847 Primary Facility 2014-04-02 Drilling/Alteration No Violations Noted Conductor set
2365045 Primary Facility 2015-04-28 Routine/Complete Inspection No Violations Noted
2452947 Primary Facility 2016-02-25 Routine/Complete Inspection No Violations Noted At time of inspection, arrived on site at 10:50 a.m., the cellar was about a quarters full of water and ice with no bubbling noticed, the (13x9) vent pipe was open and venting to a tank, the (9x5) vent pipe was open and venting to a tank, there was 677psi on the production casing. I took a walk around the location and everything looked OK.

I left the site at 11:30 a.m.

2544902 Primary Facility 2016-12-13 Routine/Complete Inspection No Violations Noted At time of inspection, arrived on site at 9:30a.m., the cellar was full of water with no bubbling noticed. The (13x9) vent pipe was open and venting into a small plastic tank, the (9x5) vent pipe was open and venting into a small plastic tank. There was 534psi on the production casing. I took a walk around the location and there were no obvious concerns noticed.

I left the site at 10:05a.m.

2632032 Primary Facility 2017-09-05 Routine/Complete Inspection No Violations Noted At time of inspection.

The well was in production. I took a walk around the location and there were no obvious concerns noticed.

2657018 Primary Facility 2017-11-06 Routine/Complete Inspection No Violations Noted I inspected the Millard K P1 well site on November 2, 2017. The site had a long access road which was stable and solid. The site's cut and fill slopes were as well vegetated as possible considering the extent of rocky ground present on site. There were no stability or erosional problems apparent.

There were no violations noted.

2728895 Primary Facility 2018-05-11 Routine/Complete Inspection No Violations Noted I performed a RTNC inspection of the Millard well site. The wells associated with this site are as follows: 115-21686, 115-21689. The wells were properly labeled.

The access road and pad surface were firm and stable. The slopes along the access road were stable.

The cut slope was very rocky as was the fill slope. Where possible, vegetation was growing but the majority of the surfaces was comprised of rock, so little vegetative growth was possible. The slopes were solid and stable. There were no erosional issues observed during this pad inspection.

There were no violations noted.

2741610 Primary Facility 2018-06-14 Routine/Complete Inspection No Violations Noted At time of inspection.

The well was in production. The (13x9) and (9x5) annuli vent pipes were connected together and going to the same poly vent tank. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted.

2836448 Primary Facility 2019-02-06 Routine/Complete Inspection No Violations Noted At time of inspection.

The well was in production. There was ice 7' below grade in the cellar and there was no gas detected. The (13x9) and (9x5) annuli vent pipes were connected together and going to the same poly vent tank. There was gas detected at the poly vent tank with a MSA Altair 5X multi gas detector that was calibrated on 2/5/19. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted.

For data sources see[9]

References