X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-115-21654

Well Details

Well ID: 37-115-21654
Loading map...
Country: United States
State: Pennsylvania
County: Susquehanna
Municipality: Auburn Township
Operator Name: CABOT OIL & GAS CORP
Well Pad ID: 150844
Farm/Lease Name: HAWK J 5
License Status:
Spud Date:
Permit Date: 2014-02-25
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.675589
Longitude: -75.972842

For data sources see[1][2][3]

Well History

Date Event
2014-02-25 New Permit Application
2014-04-16 Performed Spud Operation
2014-08-25 Drilling Completion
2014-09-27 Perforation
2014-11-18 Performed Stimulation
2015-04-15 DEVIATED

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2014-11-17 2014-12-21 7,209 9,241,930 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Hydrochloric Acid (15%) Reagent Acidizing Hydrogen Chloride 7647-01-0 15 0.0744341 64584.3
FE-4 PVS Chemical Iron Controller / Reducers Water 7732-18-5 50 0.000546271 473.983
Citric Acid 77-92-9 50 0.000546271 473.983
FR900 Nalco Friction Reducer Ammonium Sulfate 7783-20-2 25 0.0305588 26514.9
Water 7732-18-5 65 0.0794528 68938.8
Urea 57-13-6 5 0.00611175 5302.99
Vinyl Copolymer 38193-60-1 20 0.024447 21211.9
Anionic Polymer 136793-29-8 5 0.00611175 5302.99
AI 30 CorsiTech Corrosion Inhibitor Isopropyl Alcohol 67-63-0 60 0.00009813 85.142
Aromatic Aldehyne Proprietary 10 0.00001635 14.19
Alkyl Amine Surfactant Proprietary 5 0.00000818 7.095
Fatty Alcohol Ethoxylate Proprietary 30 0.00004906 42.571
Ethoxylated Alcohol Proprietary 10 0.00001635 14.19
MSI-7 PVS Energy Group Scale Inhibitor Water 7732-18-5 91.3 0.0213285 18506.1
Hydrocloric Acid 7647-01-0 9 0.00210363 1825.26
I-22 Nalco Acid Inhibitor Terpene 800-09-03 10 0.00013209 114.61
Quaternary Ammonium Compound 192562-10-6 30 0.000396269 343.831
Alkylene oxide block polymer 9003-11-006 5 0.00006604 57.305
Water 7732-18-05 3 0.00003963 34.383
Methanol 67-56-1 3 0.00003963 34.383
Quaternary Ammonium Compound 68909-18-2 5 0.00006604 57.305
Substituted Alcohol 67-63-0 10 0.00013209 114.61
Organic Sulfur Compound 60-24-2 5 0.00006604 57.305
Aromatic Aldehyde 104-55-2 30 0.000396269 343.831
Formic Acid 64-18-6 50 0.000660448 573.051
Oxyalkylated Fatty Acid 61791-12-6 30 0.000396269 343.831
Sand (Proppant) Silica Proppant Crystalline Silica in the form of Quartz 14808-60-7 99.9 10.4305 9,050,220.0
B2000 Weatherford Biocide 2,2-Dibromo-3-Nitrilopropionamide 10222-01-2 20 0.00568868 4935.9
Polyethylene Glycol Mixture 25322-68-3 60 0.017066 14807.7
Water Cabot Carrier/Base Fluid Water 7732-18-5 100 88.8862 77,123,900.0

For data sources see[5]

Stimulation Data

Stimulation Date Phase Number Chemical Agent Volume (gal) Treating Pressure (psi) Breakdown Pressure (psi)
2014-11-18 0 0 0

For data sources see[6]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2014 CABOT OIL & GAS CORP 0.00 0 0.00 0 0.00 0
2015 CABOT OIL & GAS CORP 3,416,224.21 342 0.00 0 0.00 0
2016 CABOT OIL & GAS CORP 3,201,646.16 366 0.00 0 0.00 0
2017 CABOT OIL & GAS CORP 2,066,722.63 363 0.00 0 0.00 0
2018 CABOT OIL & GAS CORP 1,645,473.00 365 0.00 0 0.00 0
2019 CABOT OIL & GAS CORP 1,213,160.00 365 0.00 0 0.00 0

For data sources see[7]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2014 CABOT OIL & GAS CORP Fracing Fluid Waste 15.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE001
2014 CABOT OIL & GAS CORP Drill Cuttings 1,511.91 Tons LANDFILL 101247
2014 CABOT OIL & GAS CORP Fracing Fluid Waste 296.50 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2015 CABOT OIL & GAS CORP Fracing Fluid Waste 226.16 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE001
2015 CABOT OIL & GAS CORP Fracing Fluid Waste 12,488.58 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2015 CABOT OIL & GAS CORP Produced Fluid 3,131.36 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2015 CABOT OIL & GAS CORP Produced Fluid 3.53 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE001
2016 CABOT OIL & GAS CORP Produced Fluid 444.93 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2016 CABOT OIL & GAS CORP Produced Fluid 442.78 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2017 CABOT OIL & GAS CORP Produced Fluid 74.45 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC018
2017 CABOT OIL & GAS CORP Produced Fluid 393.24 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2018 CABOT OIL & GAS CORP Produced Fluid 251.50 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2018 CABOT OIL & GAS CORP Produced Fluid 32.14 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC018
2019 CABOT OIL & GAS CORP Produced Fluid 451.91 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2019 CABOT OIL & GAS CORP Synthetic Liner Materials 0.04 Tons RESIDUAL WASTE TRANSFER FACILITY 101714

For data sources see[8]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2254386 Primary Facility 2014-03-18 Preoperation Inspection No Violations Noted
2266722 Primary Facility 2014-04-29 Drilling/Alteration No Violations Noted Conductor set
2298785 Primary Facility 2014-08-26 Drilling/Alteration No Violations Noted
2325877 Primary Facility 2014-11-20 Routine/Complete Inspection No Violations Noted Hydraulic fracturing operations were in progress at the location. An employee of Rain for Rent stated to me that casing perforation operations were in progress. I recorded (8.4) millisiemens/cm conductivity in fluid pooled in the recycled water tank battery secondary containment system. The frac tanks in this tank battery which is set up next to the AST, are enclosed with plastic sheeting in an attempt to prevent the fluid in the tanks from freezing. The recycled water is a mixture of mainly flowback and production fluid treated at Cabot’s A&M Hibbard Treatment Facility. I encountered Larry Fulmer, frac superintendent and consultant of Cabot Oil and Gas on the lease while departing from the site. Mr. Fulmer informed me that well stimulation procedures were in progress for the J Hawk 2H well and the fluid on containment exhibiting the elevated conductivity levels mentioned above, will be removed from the containment.
2725141 Primary Facility 2018-05-01 Routine/Complete Inspection No Violations Noted I performed a Routine Complete (RTNC) inspection of the Hawk well site on May 1, 2018. The wells associated with this site are as follows: 115-21650, 115-21651, 115-21652, 115-21653, 115-21654, 115-21655.

The wells were properly labeled.

The cut slope had prior repairs performed, consisting of riprap places in areas of instability of the cut slope. There is now an area of instability above a previous repair wherein a vegetated section is currently slumping into the riprap stabilized area. (See photo) This could potentially be a violation of 102.22(a). It is suggested the issue be repaired as soon as possible to prevent accelerated erosion. Please inform the department within 7 days or upon completion of repairs.

The fill slope is stable and well vegetated. There were no other areas of instability noted.

There are no violations noted.

2787222 Primary Facility 2018-10-09 Routine/Complete Inspection No Violations Noted I performed a RTNC inspection of the Hawk well site.

The day was overcast but dry and in the upper 60s.

The site footprint was approximately 107627 sq. ft.

The wells were properly labeled.

The well pad access road and pad surface was solid and stable.

The fill slope was lush and heavily vegetated with no noticeable stability problems.

The cut slope was vegetated but had rip rap stabilization along much of its length. It was stable however and where there was grass, it was lush and healthy.

The tree plantings at the toe of the fill slope were healthy and viable.

There were no erosional issues noted.

There were no violations noted.

For data sources see[9]

References