Well Details

Well ID: 37-115-21633
Loading map...
Country: United States
State: Pennsylvania
County: Susquehanna
Municipality: Auburn Township
Operator Name: CABOT OIL & GAS CORP
Well Pad ID: 150816
Farm/Lease Name: ANDERSON R 2
License Status:
Spud Date:
Permit Date: 2014-01-21
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.675681
Longitude: -76.032461

For data sources see[1][2][3]

Well History

Date Event
2014-01-21 New Permit Application
2014-03-05 Performed Spud Operation
2014-07-04 Drilling Completion
2014-08-25 Perforation
2014-09-19 Performed Stimulation
2015-01-30 DEVIATED

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2014-09-15 2014-09-27 7,312 4,359,310 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 PA Specific 100 mesh Sand Nabors Completion and Production Services Sand - Bulk - Pennsylvania Iron Oxide 1309-37-1 0.1 0.000591 0
Crystalline Silica, quartz 14808-60-7 99.9 0.590501 0
Titanium Oxide 13463-67-7 0.1 0.000591 0
Aluminum Oxide 1344-28-1 1.1 0.006502 0
HCL Acid 15% Nabors Completion and Production Services Bulk Acid Hydrochloric Acid 7647-01-0 15 0.078681 0
PA Specific 40/70 mesh Sand Nabors Completion and Production Services Sand - Bulk - Pennsylvania Iron Oxide 1309-37-1 0.1 0.010525 0
Crystalline Silica, quartz 14808-60-7 99.9 10.5148 0
Titanium Oxide 13463-67-7 0.1 0.010525 0
Aluminum Oxide 1344-28-1 1.1 0.115779 0
AQUCAR DB 20 Nabors Completion and Production Services Biocides Sodium bromide 7647-15-6 4 0.001124 0
2,2-Dibromo-3-nitrilo-propionamide (DBNPA) 10222-01-2 20 0.00562 0
Dibromoacetonitrile 3252-43-5 3 0.000843 0
Polyethylene glycol 25322-68-3 54.5 0.015316 0
Water CABOT OIL & GAS Water Water 7732-18-5 100 88.2189 0
Acid Inhibitor 2 (AI-2) Nabors Completion and Production Services Acid Corrosion Inhibitors Ethoxylated Nonylphenol 68412-54-4 13 0.000125 0
Propargyl Alcohol 107-19-7 40 0.000385 0
Glycol Ethers 111-46-6 40 0.000385 0
Isopropyl Alcohol 67-63-0 40 0.000385 0
Tar bases, quinoline derivs, benzyl chloride-quaternized 72480-70-7 10 0.00009600 0
Other Ingredients Nabors Completion and Production Services Other Ingredients Isoparaffinic Solvent 64742-47-8 26 0.023049 0
Dioxane 123-91-1 1 0.00001000 0
Water 7732-18-5 85 0.445859 0
Sodium Hydroxide 1310-73-2 1 0.000224 0
Surfactant Blend Proprietary 3 0.002659 0
Ethylene Glycol 107-21-1 4 0.003546 0
Monobromo-3-nitrilopropionamide 1113-55-9 1 0.000281 0
2-Propenamide as residual 79-06-1 0.1 0.00008900 0
Copolymer Proprietary 100 0.08865 0
Ethoxylated alcohols Proprietary 4 0.003546 0
2,2-Dibromomalonamide 73003-80-2 1 0.000281 0
Water 7732-18-5 48 0.000462 0
2-Butoxyethanol 111-76-2 13 0.000125 0
Water 7732-18-5 90 0.020185 0
Water 7732-18-5 32 0.008993 0
WFR-6W Nabors Completion and Production Services Friction Reducer Water 7732-18-5 40 0.03546 0
Super TSC 2 LT Nabors Completion and Production Services Paraffin & Scale Additives Bis(hexamethylene triaminepenta
(methylenephosph onic acid))
Proprietary 10 0.002243 0

For data sources see[5]

Stimulation Data

Stimulation Date Phase Number Chemical Agent Volume (gal) Treating Pressure (psi) Breakdown Pressure (psi)
2014-09-19 0 0 0

For data sources see[6]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2014 CABOT OIL & GAS CORP 481,856.66 67 0.00 0 0.00 0
2015 CABOT OIL & GAS CORP 1,375,182.67 365 0.00 0 0.00 0
2016 CABOT OIL & GAS CORP 776,219.52 366 0.00 0 0.00 0
2017 CABOT OIL & GAS CORP 532,653.55 364 0.00 0 0.00 0
2018 CABOT OIL & GAS CORP 459,558.00 353 0.00 0 0.00 0
2019 CABOT OIL & GAS CORP 386,733.00 365 0.00 0 0.00 0

For data sources see[7]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2014 CABOT OIL & GAS CORP Produced Fluid 1,068.26 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2014 CABOT OIL & GAS CORP Fracing Fluid Waste 356.94 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE001
2014 CABOT OIL & GAS CORP Drill Cuttings 1,148.18 Tons LANDFILL 100933
2014 CABOT OIL & GAS CORP Fracing Fluid Waste 10,776.70 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2014 CABOT OIL & GAS CORP Drilling Fluid Waste 35.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR119
2015 CABOT OIL & GAS CORP Produced Fluid 1,278.11 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2015 CABOT OIL & GAS CORP Produced Fluid 3.50 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE001
2016 CABOT OIL & GAS CORP Produced Fluid 167.82 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2016 CABOT OIL & GAS CORP Produced Fluid 266.17 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2017 CABOT OIL & GAS CORP Produced Fluid 93.90 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC018
2017 CABOT OIL & GAS CORP Produced Fluid 115.78 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2018 CABOT OIL & GAS CORP Synthetic Liner Materials 0.26 Tons LANDFILL 101247
2018 CABOT OIL & GAS CORP Produced Fluid 261.69 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2018 CABOT OIL & GAS CORP Produced Fluid 74.73 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC018
2019 CABOT OIL & GAS CORP Produced Fluid 255.26 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2019 CABOT OIL & GAS CORP Produced Fluid 20.24 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE004

For data sources see[8]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2246856 Primary Facility 2014-02-20 Preoperation Inspection No Violations Noted
2248958 Primary Facility 2014-02-27 Follow-up Inspection No Violations Noted
2253631 Primary Facility 2014-03-12 Drilling/Alteration No Violations Noted Conductor is set. Crew is excavating and setting cellars.
2266728 Primary Facility 2014-04-21 Routine/Complete Inspection No Violations Noted Specifics associated with this insepction can be referenced in the R Anderson 8H 4/21/14 inspection report. Permit number is 115-21632. E-facts identifcation number is 2266751.
2321608 Primary Facility 2014-11-12 Incident- Response to Accident or Event No Violations Noted Arrived at the site at 10:15 in response to a reported spill of (5) barrels, (210) gallons of flowback fluid to the ground surface of the tank pad. Brody Webster, Steve Watson and Bob Raup, Environmental Health and Safety Specialists of Cabot Oil and Gas were at the site during the inspection. There was no activity on the tank pad. Flowback procedures for all the wells at the site have recently concluded. Erick Flowback Services was subcontracted by Cabot to conduct flowback procedures. Mr. Webster reported the spill to the Department at 12:18 on 11/10/14. He also reported an additional flowback fluid spill of less than (1) barrel, (42) gallons in volume discovered on the tank pad on 11/10/14. He explained that the flowback fluid spill where (5) barrels impacted the tank pad surface, occurred due to a butterfly valve left open on a frac tank during the transfer of flowback fluid from the well pad to the tank pad.
2524740 Primary Facility 2016-10-04 Administrative/File Review No Violations Noted Reviewed Well Site Restoration Report received on 22SEP2016.
2677506 Primary Facility 2017-12-15 Routine/Complete Inspection No Violations Noted Arrived on location at: 13:30. Weather: Clear, Cold, ~ 20 degs. A total of (10) wells were present on this pad, the Anderson, R. 1H, 2H, 3H, 4H, 5H, 6H, 7H, 8H, 9H and 10H. All (10) wells were in production at time of inspection. -All wells Prod. Line, Prod. casing, Static and Differential pressures were being monitored by wireless press. monitoring units sending pressures to an onsite Total Flow Control Unit "TFCU". The TFCU Control Panel was password protected, no pressures were accessible at time of inspection. All wells (13x9) and (9x5) annuli were open and venting, plumbed to (2) shared, common vent tanks. These annuli were also equipped with wireless press. monitoring units. A Gas check performed at both shared, common vent tanks showed 100% LEL, 100% CH4. -*Due to the commingling of the wells (13x9) and (9x5) annular vents to these vent tanks, a follow-up inspection will need to be scheduled with Operator to check the (13x9) cemented annuli for any sustained presence of gas. Please contact me when the
2679695 Primary Facility 2018-01-04 Routine/Complete Inspection No Violations Noted Arrived on location at: 10:45. Weather: Light snow, Cold, ~ 20 degs. A total of (10) wells are present on this pad, the Anderson, R. 1H, 2H, 3H, 4H, 5H, 6H, 7H, 8H, 9H and 10H. All (10) wells were in production at time of inspection. -All wells Prod. Line, Prod. casing, Static and Differential pressures were being monitored by wireless press. monitoring units sending pressures to an onsite Total Flow Control Unit "TFCU". The TFCU Control Panel was password protected, no pressures were accessible at time of inspection.

-Onsite in follow-up to initial inspection performed on 12/15/17 which detected 100% LEL and 100% CH4 at both shared annuli vent tanks. In preparation for this follow-up inspection, Cabot has isolated all (10) wells (13x9) annular vents. These vents were isolated and opened to vent to atmosphere at approx. 10:00 this morning. Upon arrival to site I met with Cabot Rep. Aaron Ungst. Gas checks were performed at the (13x9) block & bleed needle valves using an Altair 5X gas meter calibrated this

2714162 Primary Facility 2018-04-04 Site Restoration No Violations Noted I performed a RTNC inspection of the Anderson well site. The access road and pad surface were stable and solid despite overnight rain. The cut slope was well vegetated, greater than 70% perennial coverage. The fill slope was very well vegetated, exceeding the 70% perennial vegetative standard. The wells were properly labeled. There were no temporary BMPs remaining on site. There were no erosional issues observed.

The wells associated with this site are as follows: 115-21632 115-21633 115-21634 115-21635 115-21636 115-21637 115-21638 115-21639 115-21640 115-21641 There were no violations noted.

2724241 Primary Facility 2018-04-27 Routine/Complete Inspection No Violations Noted I inspected the Anderson Well Site on 4/27/2018. The wells associated with this site are as follows: 115-21632, 115-21633, 115-21634, 115-21635, 115-21636, 115-21637, 115-21638, 115-21639, 115-21640, 115-21641. The wells were all properly labeled.

The cut and fill slopes were both well vegetated and stable. The access road and pad surfaces were stable and solid. There were no erosional issues apparent.

There were no violations noted.

For data sources see[9]

References