If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-115-21406 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.850786,"lon":-75.875219,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Susquehanna | |
Municipality: Bridgewater Township | |
Operator Name: CABOT OIL & GAS CORP | |
Well Pad ID: 150111 | |
Farm/Lease Name: STARZEC E 6 | |
License Status: | |
Spud Date: | |
Permit Date: 2013-08-05 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: No | |
Latitude: 41.850786 | |
Longitude: -75.875219 |
Date | Event |
---|---|
2013-08-05 | New Permit Application |
2013-09-17 | Performed Spud Operation |
2013-11-06 | Drilling Completion |
2013-11-12 | Perforation |
2013-12-07 | Performed Stimulation |
2014-03-13 | DEVIATED |
For data sources see[4]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2013-12-06 | 2013-12-14 | 6,516 | 5,444,290 | 0 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | Sand, White, 40/70 | Baker Hughes | Proppant | Crystalline Silica (Quartz) | 14808-60-7 | 100 | 10.6236 | 5,476,300.0 |
CI-14 | Baker Hughes | Corrosion Inhibitor | Polyoxyalkylenes | Trade Secret | 30 | 0.0002532 | 130.5 | |
Olefin | Trade Secret | 5 | 0.00004220 | 21.75 | ||||
Methanol | 67-56-1 | 100 | 0.0008439 | 435 | ||||
Fatty Acids | Trade Secret | 10 | 0.00008440 | 43.5 | ||||
Propargyl Alcohol | 107-19-7 | 5 | 0.00004220 | 21.75 | ||||
Water | Operator | Carrier | Water | 7732-18-5 | 100 | 88.0594 | 45,393,400.0 | |
Other Chemicals | Formaldehyde | 50-00-0 | 0 | 0.00000840 | 4.35 | |||
Sorbitan Monooleate | Trade Secret | 0 | 0.0046564 | 2400.31 | ||||
Sodium Chloride | 7647-14-5 | 0 | 0.00000450 | 2.3366 | ||||
Potassium Chloride | 7447-40-7 | 0 | 0.00000760 | 3.8944 | ||||
Ethoxylated Alcohol | Trade Secret | 0 | 0.0018626 | 960.125 | ||||
Modified Thiorea Polymer | 68527-49-1 | 0 | 0.00005910 | 30.45 | ||||
Poly (acrylamide-co-acrylic acid) | Trade Secret | 0 | 0.0279384 | 14401.9 | ||||
Polyacrylate | Trade Secret | 0 | 0.0030219 | 1557.75 | ||||
Hydrochloric Acid | 7647-01-0 | 0 | 0.00000840 | 4.35 | ||||
Water | 7732-18-5 | 0 | 0.0720321 | 37131.6 | ||||
Salt | Trade Secret | 0 | 0.0046564 | 2400.31 | ||||
Scaletrol 720 | Baker Hughes | Scale Inhibitor | Calcium Chloride | 10043-52-4 | 5 | 0.0007555 | 389.438 | |
Ethylene Glycol | 107-21-1 | 30 | 0.0045329 | 2336.63 | ||||
Sand, White, 100 mesh | Baker Hughes | Proppant | Crystalline Silica (Quartz) | 14808-60-7 | 100 | 0.59051 | 304400 | |
HCl, 10.1 - 15% | Baker Hughes | Acidizing | Hydrochloric Acid | 7647-01-0 | 15 | 0.0843932 | 43503.5 | |
Water | 7732-18-5 | 85 | 0.478228 | 246520 | ||||
Alpha 1427 | Baker Hughes | Biocide | Didecyl Dimethyl Ammonium Chloride | 7173-51-5 | 10 | 0.0028822 | 1485.75 | |
Glutaraldehyde | 111-30-8 | 30 | 0.0086467 | 4457.25 | ||||
Ethanol | 64-17-5 | 5 | 0.0014411 | 742.875 | ||||
Quaternary Ammonium Compound | 68424-85-1 | 5 | 0.0014411 | 742.875 | ||||
Ferrotrol 300L | Baker Hughes | Iron Control | Citric Acid | 77-92-9 | 60 | 0.0007338 | 378.26 | |
FRW-18 | Baker Hughes | Friction Reducer | Petroleum Distillates | 64742-47-8 | 30 | 0.0279384 | 14401.9 |
For data sources see[5]
Stimulation Date | Phase Number | Chemical Agent | Volume (gal) | Treating Pressure (psi) | Breakdown Pressure (psi) |
---|---|---|---|---|---|
2013-12-07 | 0 | 0 | 0 |
For data sources see[6]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2013 | CABOT OIL & GAS CORP | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2014 | CABOT OIL & GAS CORP | 935,007.02 | 189 | 0.00 | 0 | 0.00 | 0 |
2015 | CABOT OIL & GAS CORP | 993,434.36 | 365 | 0.00 | 0 | 0.00 | 0 |
2016 | CABOT OIL & GAS CORP | 957,261.66 | 366 | 0.00 | 0 | 0.00 | 0 |
2017 | CABOT OIL & GAS CORP | 728,676.31 | 361 | 0.00 | 0 | 0.00 | 0 |
2018 | CABOT OIL & GAS CORP | 618,401.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2019 | CABOT OIL & GAS CORP | 562,784.00 | 365 | 0.00 | 0 | 0.00 | 0 |
For data sources see[7]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2013 | CABOT OIL & GAS CORP | Drilling Fluid Waste | 1,256.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE002 |
2013 | CABOT OIL & GAS CORP | Drilling Fluid Waste | 12.50 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE001 |
2013 | CABOT OIL & GAS CORP | Drill Cuttings | 1,100.22 Tons | LANDFILL | 8-0728-0004/013 |
2013 | CABOT OIL & GAS CORP | Fracing Fluid Waste | 6,270.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE002 |
2013 | CABOT OIL & GAS CORP | Fracing Fluid Waste | 1,156.50 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE001 |
2014 | CABOT OIL & GAS CORP | Produced Fluid | 4,983.02 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE002 |
2014 | CABOT OIL & GAS CORP | Fracing Fluid Waste | 1,130.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE001 |
2014 | CABOT OIL & GAS CORP | Produced Fluid | 85.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE001 |
2014 | CABOT OIL & GAS CORP | Fracing Fluid Waste | 2,864.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE002 |
2014 | CABOT OIL & GAS CORP | Fracing Fluid Waste | 830.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC018 |
2015 | CABOT OIL & GAS CORP | Produced Fluid | 2,934.44 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE002 |
2016 | CABOT OIL & GAS CORP | Produced Fluid | 258.55 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE002 |
2016 | CABOT OIL & GAS CORP | Produced Fluid | 420.69 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC018 |
2016 | CABOT OIL & GAS CORP | Produced Fluid | 1,185.71 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE002 |
2017 | CABOT OIL & GAS CORP | Synthetic Liner Materials | 1.86 Tons | LANDFILL | 101247 |
2017 | CABOT OIL & GAS CORP | Produced Fluid | 650.83 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC018 |
2017 | CABOT OIL & GAS CORP | Produced Fluid | 466.70 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE002 |
2018 | CABOT OIL & GAS CORP | Produced Fluid | 32.94 Bbl | REUSE (AT WELL PAD) | |
2018 | CABOT OIL & GAS CORP | Produced Fluid | 717.09 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE002 |
2018 | CABOT OIL & GAS CORP | Produced Fluid | 546.20 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC018 |
2019 | CABOT OIL & GAS CORP | Produced Fluid | 1,032.50 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE002 |
For data sources see[8]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2204931 | Primary Facility | 2013-09-13 | Routine/Complete Inspection | No Violations Noted | refer to inspection ID 2204927 |
2207809 | Primary Facility | 2013-09-19 | Routine/Complete Inspection | No Violations Noted | refer to inspection # 2207807 |
2215053 | Primary Facility | 2013-10-22 | Drilling/Alteration | Violation(s) Noted | H&P Flex rig 371. Well drilled to TD using riser attached to conductor pipe. No loss of circulation while drilling as riser was attached to pump and fluids transferred to mud tanks. While preparing to run casing and cement, riser was disconnected and cellar was used to circulate bentonite drilling fluid. Report from Cabot states that approx 100 bbls of bentonite drilling mud was lost. (55 bbls while circulating and 45 bbls during running casing. Drilling fluid consists of mostly water (provided by Marcy and Brooks pumping stations) along with approx 30 sacks of bentonite and 4 sacks of lime. No known expressions at this time. Unsure of where water went. Lost of fluid was due to hole in cement of cellar between mouse hole and side wall of cellar. Pumped 11.2 bbls (15.6#) of cement into hole in which 4 bbls was lost. Performed visual inspection in which cement dropped approx 1 1/2 inches during curing process. Reason for loss: Poorly constructed cellar used for circulating while running casing in prep to cement. |
2218444 | Primary Facility | 2013-10-28 | Drilling/Alteration | No Violations Noted | |
2234494 | Primary Facility | 2014-01-06 | Routine/Complete Inspection | No Violations Noted | Details associated with this inspection can be referred to in the Starzec 3H 1-6-14 inspection report. Permit number is 115-21409. E-facts identification number is |
2254887 | Primary Facility | 2014-03-10 | Routine/Partial Inspection | No Violations Noted | |
2368978 | Primary Facility | 2015-05-12 | Routine/Complete Inspection | No Violations Noted | |
2434137 | Primary Facility | 2015-12-18 | Routine/Complete Inspection | No Violations Noted | At time of inspection, arrived on site at 11:35 a.m., the cellar was about a quarters full of water, the (13x9) vent pipe was open and venting to a tank, the (9x5) vent pipe was open and venting to a tank, there was 710psi on the production casing. I took a walk around the location and everything looked OK. |
2438960 | Primary Facility | 2016-01-07 | Routine/Complete Inspection | No Violations Noted | Inspection of the well pad in conjunction with the Corporate Pipeline notice of termination inspection. No issues observed on the well pad. |
2535784 | Primary Facility | 2016-11-09 | Routine/Complete Inspection | No Violations Noted | At time of inspection, arrived on site at 15:10p.m., the cellar was about a quarter full of water with no bubbling noticed. The (13x9) vent pipe was open and venting into a tank, the (9x5) vent pipe was open and venting into a tank. There was 501psi on the production casing. I took a walk around the location and there were no obvious concerns noticed.
I left the site at 15:45p.m. |
2570135 | Primary Facility | 2017-03-08 | Routine/Complete Inspection | No Violations Noted | The Department was on site to conduct a Routine Complete Inspection. At the time of my arrival I met with Sam Wiernusz (TEC) who was on site conducting a Post Precipitation Inspection. He joined me for the inspection. |
2624153 | Primary Facility | 2017-08-08 | Routine/Complete Inspection | No Violations Noted | At time of inspection, arrived on site at 13:05p.m.
The cellar had water at the bottom with no bubbling noticed. The (13x9) annulus vent pipe was open and venting into a small plastic tank, the (9x5) annulus vent pipe was open and venting into a small plastic tank. All the annulus vent pipes were connected to one pipe going into the same tank. There was 606psi on the production casing. I took a walk around the location and there were no obvious concerns noticed. I left the site at 13:45p.m. |
2732595 | Primary Facility | 2018-05-16 | Routine/Complete Inspection | No Violations Noted | At time of inspection.
The well was in production. There was water in the cellar 6' below grade and there was no bubbling noticed, there was no gas detected in the remainder of the cellar. The (13x9) and (9x5) annuli vent pipes were connected together and going to the same tank. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted. |
2831046 | Primary Facility | 2019-01-24 | Routine/Complete Inspection | No Violations Noted | At time of inspection.
The well was in production. There was water, snow and ice 4' below grade in the cellar with no bubbling noticed and there was no gas detected in the remainder of the cellar. The (13x9) and (9x5) annuli vent pipes were connected together and going to the same poly vent tank. There was no gas detected at the poly vent tank with a MSA Altair 5X multi gas detector that was calibrated on 1/2/19. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted. |
Inspection ID | Violation ID | Violation Date | Date Resolved | Violation Code | Violation Type | Violation Comments |
---|---|---|---|---|---|---|
2215053 | 681800 | 10/22/2013 | 2013-10-22 | 402CSL - Failure to adopt pollution prevention measures required or prescribed by DEP by handling materials that create a danger of pollution. | Environmental Health & Safety | Loss of 100 bbls of Bentonite drilling mud and 4 bbls of cement into subsurface due to poorly constructed cellar used for circulating while running casing in prep to cement. Adequate NOV response rec'vd 11/21/13, investigation revealed no impacts discovered during investigation. |
2215053 | 681801 | 10/22/2013 | 2013-10-22 | 78.56(1) - Pit and tanks not constructed with sufficient capacity to contain pollutional substances. | Administrative | Loss of 100 bbls of Bentonite drilling mud and 4 bbls of cement into subsurface due to poorly constructed cellar used for circulating while running casing in prep to cement. Adequate NOV response rec'vd 11/21/13, investigation revealed no impacts discovered during investigation. |
2215053 | 681802 | 10/22/2013 | 2013-10-22 | SWMA301 - Failure to properly store, transport, process or dispose of a residual waste. | Environmental Health & Safety | Loss of 100 bbls of Bentonite drilling mud and 4 bbls of cement into subsurface due to poorly constructed cellar used for circulating while running casing in prep to cement. Adequate NOV response rec'vd 11/21/13, investigation revealed no impacts discovered during investigation. |
Violation ID | Penalty ID | Penalty Code | Penalty Status | Penalty Date | Enforcement Date | Penalty Amount | Amount Collected |
---|---|---|---|---|---|---|---|
681800 | 304158 | NOV - Notice of Violation | Administrative Close Out | 2013-11-21 | |||
681801 | 304158 | NOV - Notice of Violation | Administrative Close Out | 2013-11-21 | |||
681802 | 304158 | NOV - Notice of Violation | Administrative Close Out | 2013-11-21 |
For data sources see[9]