37-115-21348

Well Details

Well ID: 37-115-21348
Loading map...
Country: United States
State: Pennsylvania
County: Susquehanna
Municipality: Jessup Township
Operator Name: CABOT OIL & GAS CORP
Well Pad ID: 145784
Farm/Lease Name: REYNOLDS R 3
License Status:
Spud Date:
Permit Date: 2013-07-03
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.816772
Longitude: -76.006183

For data sources see[1][2][3]

Well History

Date Event
2013-07-03 New Permit Application
2013-08-14 Performed Spud Operation
2013-10-31 Drilling Completion
2013-11-12 Perforation
2013-11-19 Performed Stimulation
2014-03-12 DEVIATED

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2013-11-18 2013-12-05 6,338 7,362,780 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 15% HCL WFT Acid Hydrochloric Acid 7647-01-0 15 0.081326 0
WIC-641L WFT Iron Control Citric acid 77-92-9 60 0.003731 0
WBK-134 WFT Breaker Ammonium Persulfate 7727-54-0 75 0.00013 0
WGA-15L WFT Gelling Agents Petroleum Distillates 64742-47-8 60 0.016872 0
WXL-106L WFT Crosslink Control Potassium Hydroxide 1310-58-3 15 0.000576 0
Potassium tetraborate 1332-77-0 40 0.001536 0
Inhibitor WFT Inhibitor Ammonium Chloride 12125-02-9 15 0.004314 0
Methyl Alcohol 67-56-1 2.5 0.000719 0
Monoethanolamine Hydrochloride 2002-24-6 15 0.004314 0
100 Mesh Sand WFT Proppant Crystalline Silica in the form of Quartz 14808-60-7 100 0.611513 0
WFR-61LA WFT Friction Reducer Ammonium chloride 12125-02-9 5 0.004594 0
Petroleum Distillates 64742-47-8 20 0.018377 0
Alcohols, C12-16, Ethoxylated 68551-12-2 5 0.004594 0
WAI-251LC WFT Inhibitor Ethylene Glycol 111-76-2 40 0.000429 0
2-Butoxyethanol 111-76-2 10 0.000107 0
Ethoxylated Nonylphenol 68412-54-4 5 0.00005400 0
1-Decanol 112-30-1 5 0.00005400 0
Isopropyl Alcohol 67-63-0 5 0.00005400 0
1-Octanol 111-87-5 5 0.00005400 0
N,N-Dimethylformamide 68-12-2 20 0.000215 0
Triethylphosphate 78-40-0 5 0.00005400 0
Tar bases, quinoline derivs, benzyl chloride-quaternized 72480-70-7 10 0.000107 0
Water Cabot Oil & Gas Carrier / Base Fluid Carrier / Base Fluid - Water 7732-18-5 100 88.3352 0
40/70 Premium WFT Proppant Crystalline Silica in the form of Quartz 14808-60-7 100 10.785 0
Bio-Clear® 5000 WFT Bactericide 2,2-dibromo-3-nitriloproppionamide 10222-01-2 5 0.001337 0
Polyethylene Glycol 25322-68-3 50 0.01337 0
WBK-133 WFT Breaker Ammonium Persulfate 7727-54-0 100 0.000216 0

For data sources see[5]

Stimulation Data

Stimulation Date Phase Number Chemical Agent Volume (gal) Treating Pressure (psi) Breakdown Pressure (psi)
2013-11-19 0 0 0

For data sources see[6]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2013 CABOT OIL & GAS CORP 34,279.78 9 0.00 0 0.00 0
2014 CABOT OIL & GAS CORP 874,549.89 359 0.00 0 0.00 0
2015 CABOT OIL & GAS CORP 648,703.92 365 0.00 0 0.00 0
2016 CABOT OIL & GAS CORP 642,345.73 353 0.00 0 0.00 0
2017 CABOT OIL & GAS CORP 549,776.76 365 0.00 0 0.00 0
2018 CABOT OIL & GAS CORP 473,747.00 365 0.00 0 0.00 0
2019 CABOT OIL & GAS CORP 428,709.00 356 0.00 0 0.00 0

For data sources see[7]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2013 CABOT OIL & GAS CORP Drilling Fluid Waste 1,084.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2013 CABOT OIL & GAS CORP Produced Fluid 11,610.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2013 CABOT OIL & GAS CORP Drill Cuttings 95.75 Tons LANDFILL THR029
2013 CABOT OIL & GAS CORP Drilling Fluid Waste 183.67 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE001
2013 CABOT OIL & GAS CORP Drill Cuttings 1,103.39 Tons LANDFILL 100933
2013 CABOT OIL & GAS CORP Fracing Fluid Waste 5,081.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2013 CABOT OIL & GAS CORP Fracing Fluid Waste 3,087.67 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE001
2014 CABOT OIL & GAS CORP Produced Fluid 16,470.98 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2014 CABOT OIL & GAS CORP Fracing Fluid Waste 220.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE001
2014 CABOT OIL & GAS CORP Produced Fluid 8.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE001
2014 CABOT OIL & GAS CORP Fracing Fluid Waste 3,672.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2015 CABOT OIL & GAS CORP Produced Fluid 61.76 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE001
2015 CABOT OIL & GAS CORP Produced Fluid 4,681.07 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2016 CABOT OIL & GAS CORP Synthetic Liner Materials 1.01 Tons LANDFILL 101247
2016 CABOT OIL & GAS CORP Produced Fluid 617.66 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2016 CABOT OIL & GAS CORP Produced Fluid 999.03 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC018
2016 CABOT OIL & GAS CORP Produced Fluid 2,526.66 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2017 CABOT OIL & GAS CORP Produced Fluid 2,826.76 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC018
2017 CABOT OIL & GAS CORP Produced Fluid 374.59 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2017 CABOT OIL & GAS CORP Produced Fluid 39.28 Bbl REUSE (AT WELL PAD)
2018 CABOT OIL & GAS CORP Produced Fluid 136.70 Bbl REUSE (AT WELL PAD)
2018 CABOT OIL & GAS CORP Produced Fluid 1,163.66 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2018 CABOT OIL & GAS CORP Produced Fluid 923.12 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC018
2019 CABOT OIL & GAS CORP Produced Fluid 1,352.49 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2019 CABOT OIL & GAS CORP Produced Fluid 21.10 Bbl REUSE (AT WELL PAD)

For data sources see[8]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2224067 Primary Facility 2013-07-18 Routine/Complete Inspection No Violations Noted The Department was on site at the Cabot Reynolds R. P. Well Site to conduct a Preoperational Inspection. Well permits that have been issued for this pad are the 3H (115-21348), 4H (115-21349), and the 5H (115-21350). All perimeter BMP’s in place and include red lined additions. The temporary Sediment Trap #1 has been installed to include the 11’ spill way. Pad construction has not been started yet. No violations noted.
2235838 Primary Facility 2014-01-13 Incident- Response to Accident or Event No Violations Noted Explosion in tank resulted in release of production fluid. Violations and specifics associated with inspection can be referred to in the R Reynolds 4H 1-3-14 inspection report. Permit number is 115-21349. E-facts identification number is 2236813. MBC data clean-up 1/6/15.
2236842 Primary Facility 2014-01-13 Incident- Response to Accident or Event No Violations Noted Violations and specifics associated with inspection can be referred to in the R Reynolds 4H 1-3-14 inspection report. Permit number is 115-21349. E-facts identification number is 2236813.
2366127 Primary Facility 2015-05-01 Routine/Complete Inspection No Violations Noted
2455481 Primary Facility 2016-03-03 Routine/Complete Inspection No Violations Noted At time of inspection, arrived on site at 11:50 a.m., the cellar was full of water and ice with no bubbling noticed, the (13x9) vent pipe was open and venting to a tank, the (9x5) vent pipe was open and venting to a tank, there was 634psi on the production casing. I took a walk around the location and everything looked OK.

I left the site at 12:20 p.m.

2545884 Primary Facility 2016-12-16 Routine/Complete Inspection No Violations Noted At time of inspection, arrived on site at 9:14a.m., the cellar was about a quarter full of ice and snow. The (13x9) vent pipe was open and venting into a small plastic tank, the (9x5) vent pipe was open and venting into a small plastic tank. There was 688psi on the production casing and 560psi on the production line. I took a walk around the location and there were no obvious concerns noticed.

I left the site at 9:40a.m.

2632271 Primary Facility 2017-09-05 Routine/Complete Inspection No Violations Noted At time of inspection.

The well was in production. I took a walk around the location and there were no obvious concerns noticed.

2729175 Primary Facility 2018-05-11 Routine/Complete Inspection No Violations Noted I performed a RTNC inspection on the Reynolds R pad. The wells associated with this site are as follows: 115-21348, 115-21349, 115-21350. The wells were properly labeled.

The pad surface and access road were solid and stable.

The cut slope showed evidence of previous repairs but was otherwise well vegetated. There did not appear to be any areas of instability.

The fill slope had a rill forming midway across the face. (See photo) There was apparently a drain from the pad surface daylighted near the South side of the pad. Downhill from this drain was a somewhat swampy area that appeared to be eroding. At this point the erosion from the small rill and pad drain is minimal but it is recommended this should be addressed promptly. (See photos)

There was an infiltration basin that had an overflow rock apron over plastic. The rock has been pushed off the plastic by the force of runoff. (See photo) It is recommended this be repaired promptly.

There were BMPs remaining at the toe of the fill slope which

2741495 Primary Facility 2018-06-14 Routine/Complete Inspection No Violations Noted At time of inspection.

The well was in production. The (13x9) and (9x5) annuli vent pipes were connected together and going to the same poly vent tank. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted.

2836614 Primary Facility 2019-02-06 Routine/Complete Inspection No Violations Noted At time of inspection.

The well was in production. The cellar was full of water and ice, there was no bubbling noticed. The (13x9) and (9x5) annuli vent pipes were connected together and going to the same poly vent tank. There was gas detected at the poly vent tank with a MSA Altair 5X multi gas detector that was calibrated on 2/5/19. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted.

For data sources see[9]

References