37-115-21317

Well Details

Well ID: 37-115-21317
Loading map...
Country: United States
State: Pennsylvania
County: Susquehanna
Municipality: Gibson Township
Operator Name: CABOT OIL & GAS CORP
Well Pad ID: 145684
Farm/Lease Name: BINIEWICZ S 5
License Status:
Spud Date:
Permit Date: 2013-07-11
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.802111
Longitude: -75.655939

For data sources see[1][2][3]

Well History

Date Event
2013-07-11 New Permit Application
2013-08-31 Performed Spud Operation
2013-12-26 Drilling Completion
2014-01-11 Perforation
2014-02-01 Performed Stimulation
2014-05-01 DEVIATED

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2014-01-31 2014-02-06 6,763 4,457,710 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 CI-14 Baker Hughes Corrosion Inhibitor Methanol 67-56-1 100 0.000888 377
Fatty Acids Trade Secret 10 0.00008880 37.7
Polyoxyalkylenes Trade Secret 30 0.0002664 113.1
Propargyl Alcohol 107-19-7 5 0.00004440 18.85
Olefin Trade Secret 5 0.00004440 18.85
Sand, White, 100 mesh Baker Hughes Proppant Crystalline Silica (Quartz) 14808-60-7 100 0.614037 260700
Water Operator Carrier Water 7732-18-5 100 87.5421 37,167,500.0
Other Chemicals Water 7732-18-5 0 0.0690155 29301.8
Sodium Chloride 7647-14-5 0 0.00000450 1.9199
Formaldehyde 50-00-0 0 0.00000890 3.77
Poly (acrylamide-co-acrylic acid) Trade Secret 0 0.0282011 11973.3
Modified Thiorea Polymer 68527-49-1 0 0.00006220 26.39
Ethoxylated Alcohol Trade Secret 0 0.0018801 798.218
Sorbitan Monooleate Trade Secret 0 0.0047002 1995.55
Polyacrylate Trade Secret 0 0.0030147 1279.94
Potassium Chloride 7447-40-7 0 0.00000750 3.1998
Salt Trade Secret 0 0.0047002 1995.55
Hydrochloric Acid 7647-01-0 0 0.00000890 3.77
HCl, 10.1 - 15% Baker Hughes Acidizing Hydrochloric Acid 7647-01-0 15 0.0888034 37703.1
Water 7732-18-5 85 0.50322 213651
Ferrotrol 300L Baker Hughes Iron Control Citric Acid 77-92-9 60 0.0007721 327.826
Scaletrol 720 Baker Hughes Scale Inhibitor Ethylene Glycol 107-21-1 30 0.004522 1919.9
Calcium Chloride 10043-52-4 5 0.0007537 319.984
FRW-18 Baker Hughes Friction Reducer Petroleum Distillates 64742-47-8 30 0.0282011 11973.3
Sand, White, 40/70 Baker Hughes Proppant Crystalline Silica (Quartz) 14808-60-7 100 11.0932 4,709,800.0
Alpha 1427 Baker Hughes Biocide Glutaraldehyde 111-30-8 30 0.0069123 2934.75
Didecyl Dimethyl Ammonium Chloride 7173-51-5 10 0.0023041 978.25
Ethanol 64-17-5 5 0.0011521 489.125
Quaternary Ammonium Compound 68424-85-1 5 0.0011521 489.125

For data sources see[5]

Stimulation Data

Stimulation Date Phase Number Chemical Agent Volume (gal) Treating Pressure (psi) Breakdown Pressure (psi)
2014-02-01 0 0 0

For data sources see[6]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2013 CABOT OIL & GAS CORP 0.00 0 0.00 0 0.00 0
2014 CABOT OIL & GAS CORP 557,138.23 106 0.00 0 0.00 0
2015 CABOT OIL & GAS CORP 961,011.19 365 0.00 0 0.00 0
2016 CABOT OIL & GAS CORP 593,561.18 365 0.00 0 0.00 0
2017 CABOT OIL & GAS CORP 331,048.06 358 0.00 0 0.00 0
2018 CABOT OIL & GAS CORP 353,881.00 365 0.00 0 0.00 0
2019 CABOT OIL & GAS CORP 282,322.00 365 0.00 0 0.00 0

For data sources see[7]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2013 CABOT OIL & GAS CORP Drilling Fluid Waste 1,531.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2013 CABOT OIL & GAS CORP Drilling Fluid Waste 26.67 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE001
2013 CABOT OIL & GAS CORP Drill Cuttings 198.89 Tons LANDFILL 8-0728-0004/013
2013 CABOT OIL & GAS CORP Drill Cuttings 1,265.27 Tons LANDFILL 100933
2014 CABOT OIL & GAS CORP Produced Fluid 3,654.71 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2014 CABOT OIL & GAS CORP Drilling Fluid Waste 392.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2014 CABOT OIL & GAS CORP Fracing Fluid Waste 14,141.24 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2015 CABOT OIL & GAS CORP Produced Fluid 2,107.39 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2015 CABOT OIL & GAS CORP Produced Fluid 2.92 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE001
2016 CABOT OIL & GAS CORP Produced Fluid 5.35 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NE004
2016 CABOT OIL & GAS CORP Produced Fluid 156.16 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2016 CABOT OIL & GAS CORP Produced Fluid 155.45 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2017 CABOT OIL & GAS CORP Synthetic Liner Materials 0.96 Tons LANDFILL 101247
2017 CABOT OIL & GAS CORP Produced Fluid 38.21 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC018
2017 CABOT OIL & GAS CORP Produced Fluid 82.58 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE004
2017 CABOT OIL & GAS CORP Produced Fluid 54.07 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2018 CABOT OIL & GAS CORP Produced Fluid 5.69 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE004
2018 CABOT OIL & GAS CORP Produced Fluid 174.86 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2018 CABOT OIL & GAS CORP Produced Fluid 43.26 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC018
2019 CABOT OIL & GAS CORP Produced Fluid 12.89 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2019 CABOT OIL & GAS CORP Produced Fluid 241.51 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE004

For data sources see[8]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2197543 Primary Facility 2013-08-21 Routine/Complete Inspection No Violations Noted The Department was on site at the Biniewicz, S. Pad to conduct a Preoperational Inspection. Well permits that have been issued for this pad are the 1H (115-21313), 2H (115-21314), 3H (115-21315), 5H (115-21317), and the 6H (115-21318). All perimeter BMP’s in place. Pad is approximately 95% complete. No violations noted.
2227387 Primary Facility 2013-12-09 Drilling/Alteration No Violations Noted moved onto well 0600 this date re-entry
2230125 Primary Facility 2013-12-16 Drilling/Alteration No Violations Noted cement log incl.
2257239 Primary Facility 2014-03-26 Drilling/Alteration No Violations Noted
2316026 Primary Facility 2014-10-24 Routine/Complete Inspection No Violations Noted The Department conducted an inspection of the Cabot Biniewicz, S. Pad on 10/24/14 in response to a nearby water supply complaint. There are 6 wells drilled and in production on this pad. They are: Biniewicz 1H (115-21313), 2H (115-21314), 3H (115-21315), 4H (115-21316), 5H (115-21317), and the 6H (115-21318). The inspection revealed that the pad was constructed per the plan. There has been no drilling activity on this pad for the last 6 months. No violations were observed at the pad site.
2468340 Primary Facility 2016-03-25 Routine/Complete Inspection No Violations Noted
2513816 Primary Facility 2016-08-25 Routine/Complete Inspection No Violations Noted On 8/25/16, the Department conducted an inspection of the COG Biniewicz, S. Pad located in Gibson Township, Susquehanna County. Last Cabot E&S inspection documented at site as having been conducted on 8/22/16. The entrance to the access road is also the shared driveway and parking area for a house located at the entrance. The access road is paved for about 50’. All six wells have been drilled, stimulated, and appear to be in production. The well pad berms have been eliminated. The tank pad has been reclaimed with what appears to be the tank pad modified material for the pad having been used to create an access road presumably for the landowners use to access his property from the well pad access road. The new owner access road cuts across the old tank pad location and proceeds to the wood line across the diversion swale. A cross culvert pipe has been placed in this swale. The culvert pipe is elevated approximately 1’ from the contour of the diversion swale. Recent heavy rain events suggest this cha
2530210 Primary Facility 2016-10-13 Routine/Complete Inspection No Violations Noted
2530340 Primary Facility 2016-10-12 Routine/Complete Inspection No Violations Noted
2542194 Primary Facility 2016-12-07 Routine/Complete Inspection No Violations Noted The Department was on site, to conduct a Routine Complete Inspection, in response to the submittal of a Restoration Report. The E&S Inspection Log indicated that Stephen P. Opteka conducted the most recent inspection on 12/1/16 and it was a Post Rain Event Inspection.

On site it was noted that what appeared to be new filter sock was situated along the access road and well site and it appeared to be in place for the pipeline. The PCSM/ Site Restoration Plan 1 Map noted that the proposed earthen level spreader has been substitutued for an existing subsurface level spreader.

The tank pad has been removed and is now vegetated.

2552356 Primary Facility 2017-01-12 Routine/Complete Inspection No Violations Noted At time of inspection, arrived on site at 11:35a.m., the cellar was full of water and ice with no bubbling noticed. The (13x9) vent pipe was open and venting into a small plastic tank, the (9x5) vent pipe was open and venting into a small plastic tank. There was 574psi on the production casing. I took a walk around the location and there were no obvious concerns noticed.

I left the site at 12:15p.m.

2639956 Primary Facility 2017-09-26 Routine/Complete Inspection No Violations Noted At time of inspection.

The well was in production. There was containment at the 5H and appeared tubing was recently put in the wells. All the annulus vent pipes were connected together and going to the same tank. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted.

2655050 Primary Facility 2017-10-26 Site Restoration No Violations Noted This inspection was conducted to confirm Cabot's assessment that the project meets the minimum requirements for permanent stabilization. The Departments determination is that the site meets the requirements for permit termination.
2745584 Primary Facility 2018-06-26 Routine/Complete Inspection No Violations Noted At time of inspection.

The well was in production. There was water 1.5' below grade in the cellar with no bubbling noticed and there was no gas detected in the remainder of the cellar. The (13x9) and (9x5) annuli vent pipes were connected together and going to the same tank. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted.

2844932 Primary Facility 2019-02-26 Routine/Complete Inspection No Violations Noted At time of inspection.

The well was in production. There was ice 1.5' below grade in the cellar and I was unable to check for gas. The (13x9) and (9x5) annuli vent pipes were connected together and going to the same poly vent tank. There was no gas detected at the poly vent tank with a MSA Altair 5X multi gas detector that was calibrated on 2/5/19. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted.

For data sources see[9]