37-115-21263

Well Details

Well ID: 37-115-21263
Loading map...
Country: United States
State: Pennsylvania
County: Susquehanna
Municipality: Harford Township
Operator Name: CABOT OIL & GAS CORP
Well Pad ID: 147696
Farm/Lease Name: ADAMS J 4
License Status:
Spud Date:
Permit Date: 2013-05-13
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.771361
Longitude: -75.699964

For data sources see[1][2][3]

Well History

Date Event
2013-05-13 New Permit Application
2013-06-28 Performed Spud Operation
2013-08-15 New Permit Application
2013-09-10 Drilling Completion
2013-12-06 Perforation
2013-12-17 Performed Stimulation
2014-04-30 DEVIATED

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2013-12-16 2014-01-02 7,100 14,574,000 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 BXL-2 FTSI Borate crosslinker Potassium hydroxide 1310-58-3 12 0.000110078 151.08
Boric acid 10043-35-3 15 0.000137598 188.86
Water 7732-18-5 75 0.00068799 944.28
Sodium metaborate 10555-76-7 25 0.00022933 314.76
40/70 White FTSI proppant Silica, Quartz 14808-60-7 100 10.1792 13,971,100.0
BIO-3240 FTSI Biocide Water 7732-18-5 55 0.0145626 19987.5
Dazomet (Tetrahydro-3, 5-dimethyl-2H-1,
3, 5-thiadiazine-2-thione.
533-74-4 24 0.0063546 8721.82
Sodium Hydroxide 1310-73-2 23 0.00608983 8358.41
FRW-200 FTSI Friction reducer Acrylamide P/W acrylic acid, ammonium salt 26100-47-0 25 0.0246783 33871.5
Hydrotreated heavy paraffinic 64742-54-7 5 0.00493566 6774.29
Alkyloxypolyethyleneoxyethanol 84133-50-6 1 0.000987132 1354.86
Surfactant Proprietary 7 0.00690992 9484.01
Alcohols (C12-C14), ethoxylated 68439-50-9 4 0.00394853 5419.44
Dewaxed heavy paraffinic 64742-65-0 1.5 0.0014807 2032.29
Alcohols (C12-C16), ethoxylated 68551-12-2 4 0.00394853 5419.44
Acrylamide 79-06-1 0.1 0.00009871 135.49
Ammonium Acrylate 10604-69-0 0.5 0.000493566 677.43
Water 7732-18-5 48 0.0473823 65033.2
Polyethylene glycol monooleate 9004-96-0 3 0.0029614 4064.58
Sorbitol Tetraoleate 61723-83-9 2 0.00197426 2709.72
Copolymer of acrylamide and sodium acrylate 25987-30-8 33 0.0325753 44710.3
Petroleum distillate hydrotreated light 64742-47-8 26 0.0256654 35226.3
Ammonium Chloride 12125-02-9 12 0.0118456 16258.3
Alcohols (C10-C16), ethoxylated 68002-97-1 4 0.00394853 5419.44
Sorbitan Monooleate 1338-43-8 3 0.0029614 4064.58
Isopropanol 67-63-0 0.3 0.00029614 406.46
CS-500 SI FTSI Scale inhibitor Sodium chloride 7647-14-5 6 0.00156764 2151.62
Water 7732-18-5 55 0.01437 19723.1
Ethylene glycol 107-21-1 10 0.00261273 3586.03
Acrylic Polymer Proprietary 0 0 0
Sodium Polyacrylate 9003-04-7 5 0.00130636 1793.01
CI-150 FTSI Acid Corrosion Inhibitor Ethylene Glycol 107-21-1 30 0.000279602 383.76
Isopropanol 67-63-0 30 0.000279602 383.76
Organic amine resin salt Proprietary 30 0.000279602 383.76
Water 7732-18-5 5 0.00004660 63.96
Aliphatic alcohol Proprietary 0.1 0.00000093 1.28
Dimethylformamide 68-12-2 10 0.00009320 127.92
Fatty Acid Salt Proprietary 0.1 0.00000093 1.28
Aromatic aldehyde Proprietary 10 0.00009320 127.92
Quaternary ammonium compound Proprietary 10 0.00009320 127.92
Diethylene glycol 111-46-6 1 0.00000932 12.79
Fatty Acid Proprietary 0.1 0.00000093 1.28
Alkylene Oxide Block Polymer Proprietary 10 0.00009320 127.92
Hydrochloric Acid (HCl) FTSI Acid Hydrogen Chloride 7647-01-0 15 0.0791922 108693
Water 7732-18-5 85 0.448756 615927
HVG-1 FTSI Water Gelling Agent Raffinates (Petroleum), Sorption Process 64741-85-1 50 0.00455753 6255.3
Surfactant 154518-36-2 1 0.00009115 125.11
Clay 14808-60-7 2 0.000182301 250.21
Guar Gum 9000-30-0 55 0.00501328 6880.83
Clay 1302-78-9 5 0.000455753 625.53
Petroleum Distillate 64742-47-8 55 0.00501328 6880.83
Surfactant 9043-30-5 1 0.00009115 125.11
Surfactant 24938-91-8 1 0.00009115 125.11
Water Operator Carrier Water 7732-18-5 100 88.5579 121,548,000.0
FE-100L FTSI Iron control Water 7732-18-5 60 0.00100452 1378.73
Citric acid 77-92-9 55 0.000920812 1263.83
100 Mesh Sand FTSI proppant Silica, Quartz 14808-60-7 100 0.57092 783600
APB-1 FTSI Gel breaker Ammonium Persulfate 7727-54-0 100 0.000151546 208

For data sources see[5]

Stimulation Data

Stimulation Date Phase Number Chemical Agent Volume (gal) Treating Pressure (psi) Breakdown Pressure (psi)
2013-12-17 0 0 0

For data sources see[6]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2013 CABOT OIL & GAS CORP 0.00 0 0.00 0 0.00 0
2014 CABOT OIL & GAS CORP 7,036,639.79 348 0.00 0 0.00 0
2015 CABOT OIL & GAS CORP 4,400,140.21 365 0.00 0 0.00 0
2016 CABOT OIL & GAS CORP 3,016,492.61 366 0.00 0 0.00 0
2017 CABOT OIL & GAS CORP 2,115,576.39 365 0.00 0 0.00 0
2018 CABOT OIL & GAS CORP 872,952.00 177 0.00 0 0.00 0
2019 CABOT OIL & GAS CORP 1,546,464.00 293 0.00 0 0.00 0

For data sources see[7]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2013 CABOT OIL & GAS CORP Drilling Fluid Waste 1,501.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2013 CABOT OIL & GAS CORP Servicing Fluid 60.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2013 CABOT OIL & GAS CORP Servicing Fluid 2,052.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE001
2013 CABOT OIL & GAS CORP Drill Cuttings 990.11 Tons LANDFILL 101247
2013 CABOT OIL & GAS CORP Drilling Fluid Waste 258.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE001
2013 CABOT OIL & GAS CORP Drill Cuttings 506.16 Tons LANDFILL THR029
2013 CABOT OIL & GAS CORP Fracing Fluid Waste 585.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2014 CABOT OIL & GAS CORP Fracing Fluid Waste 3,633.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE001
2014 CABOT OIL & GAS CORP Produced Fluid 9,979.67 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2014 CABOT OIL & GAS CORP Fracing Fluid Waste 26,649.88 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2014 CABOT OIL & GAS CORP Produced Fluid 135.50 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE001
2014 CABOT OIL & GAS CORP Servicing Fluid 17.50 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE001
2015 CABOT OIL & GAS CORP Produced Fluid 1,989.48 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2015 CABOT OIL & GAS CORP Produced Fluid 4.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE001
2016 CABOT OIL & GAS CORP Produced Fluid 569.87 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2016 CABOT OIL & GAS CORP Produced Fluid 729.61 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2017 CABOT OIL & GAS CORP Produced Fluid 158.66 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2017 CABOT OIL & GAS CORP Produced Fluid 327.49 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE004
2017 CABOT OIL & GAS CORP Synthetic Liner Materials 1.87 Tons LANDFILL 101247
2017 CABOT OIL & GAS CORP Produced Fluid 330.66 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC018
2018 CABOT OIL & GAS CORP Produced Fluid 231.80 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2018 CABOT OIL & GAS CORP Produced Fluid 142.55 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC018
2019 CABOT OIL & GAS CORP Produced Fluid 233.50 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2019 CABOT OIL & GAS CORP Synthetic Liner Materials 0.06 Tons RESIDUAL WASTE TRANSFER FACILITY 101714
2019 CABOT OIL & GAS CORP Produced Fluid 1,157.37 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE004
2019 CABOT OIL & GAS CORP Waste Water Treatment Sludge 1.47 Tons REUSE (AT WELL PAD)

For data sources see[8]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2180075 Primary Facility 2013-06-25 Routine/Complete Inspection No Violations Noted The Department was on site at the Adams J Well Site to conduct a Preoperational Inspection. Well permits that have been issued for this pad are the 1H (115-21261), 2H (115-21262), 4H (115-21263), and the 6H (115-21264). Inspection conducted with George Bishop of GDS. All perimeter BMP’s in place. Pipeline is actively being installed across the access road approximately 600’ from the entrance. In process of hydroseeding the pad with approximately 65% complete. Pad is approximately 95% complete.
2211822 Primary Facility 2013-10-09 Incident- Response to Accident or Event No Violations Noted Violations associated with this inspection can be referred to in the J Adams 1 inspection report. Permit number is 115-21261. E-facts identification number is 2211789.
2235833 Primary Facility 2014-01-13 Drilling/Alteration No Violations Noted
2240631 Primary Facility 2014-01-29 Drilling/Alteration No Violations Noted
2245762 Primary Facility 2013-12-16 Incident- Response to Accident or Event Violation(s) Noted An estimated (50) to (75) barrels of recycled flowback fluid flowed out of a man way door on Rain for Rent frac tank number (257755) onto the tank battery secondary containment in the northeast corner of the Pad. A valve was not locked on the tank as it was in the process of being filled. A portion of the fluid escaped secondary containment and impacted the surface of the ground at the site. The impact to the ground surface is apparently due to compromised liner integrity and overflow of the fluid on containment to the ground surface. Compromised liner integrity was observed near the tank battery containment berm. I recorded elevated conductivity readings, over range on my meter on and off containment on the Pad and in an interceptor trench just the below the Pad dug to collect the fluid as a subsurface release is apparent.
2507141 Primary Facility 2016-08-01 Routine/Complete Inspection No Violations Noted At time of inspection, arrived on site at 13:05p.m., the permit number on the well was unreadable, the cellar was about half full of water with no bubbling noticed but had debris in it, the (13x9) vent pipe was open and venting into a tank, the (9x5) vent pipe was open and venting into a tank, there was 519psi on the production casing. I took a walk around the location and noticed a role back container full of containment that was not on containment and not sealed. I contacted Steve Watson of Cabot Oil and Gas to let him know of my inspection and he told me he would get everything taken care of.

I left the site at 13:45p.m.

2533317 Primary Facility 2016-11-01 Routine/Complete Inspection No Violations Noted On 11/1/16, the Department conducted an inspection of the COG Adams J Well Site located in Harford Township, Susquehanna County in response to a nearby malodor complaint. The Department arrived on-site at approximately 10:00 AM. There are 2 wells drilled and in production on this pad, the 4H and the 6H. The 1H and 2H were proposed but never built. The pad only has the standard equipment associated with steady state production. No other activity is occurring at this pad. I spent approximately 5 minutes at each corner of the well pad and did not detect any malodors. No E&S issues were observed during this inspection. No violations noted.
2605588 Primary Facility 2017-06-15 Routine/Complete Inspection No Violations Noted At time of inspection, arrived on site at 13:55p.m.

The cellar had water at the bottom with no bubbling noticed. The (13x9) annulus vent pipe was open and venting into a small plastic tank, the (9x5) annulus vent pipe was open and venting into a small plastic tank. There was 494psi on the production casing. I took a walk around the location and there were no obvious concerns noticed. I left the site at 14:30p.m.

2708489 Primary Facility 2018-03-22 Routine/Complete Inspection No Violations Noted At time of inspection.

The well was in production. There was ice 4' below grade in the cellar and there was no gas detected from there to the surface. The (13x9) and (9x5) annuli vent pipes are connected together and going to the same tank. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted.

2750981 Primary Facility 2018-07-09 Routine/Complete Inspection No Violations Noted Today's inspection was conducted as part of an investigation into a nearby water supply complaint in which the water well was impacted by a heavy sediment load on 7/3/18. As Photo #2 shows, new wells have recently been spud on this pad. A review of the most recent Department Drilling Inspection, Inspection Record No. 2748434 found that conductor pipe was installed on 7/3/18 for 7 wells, the 1H, 2H, 3H, 5H, 7H, 8H, and the 10H. The conductors were all drilled to a depth of approximately 105'. During the 7/3/18 inspection, the inspector noted that 3 Rigs were being operated, one auger rig and two air rigs. No E&S issues were identified. No violations noted.
2850436 Primary Facility 2019-03-07 Routine/Complete Inspection No Violations Noted Today's inspection was conducted as a routine inspection. Present during the inspection was Cabot Site Supervisor Steve Gillman. Stimulation activities have been completed and site is currently being demobilized. Production equipment installation is also occurring. Overall the site appears to have good stabilization. No E&S issues identified. No violations noted.

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
2245762 688893 12/16/2013 2013-12-16 401 CSL - Discharge of pollultional material to waters of Commonwealth. Environmental Health & Safety Discharge of pollutional substances into waters of the Commonwealth.
2245762 688894 12/16/2013 2013-12-16 91.34A - Failure to take all necessary measures to prevent spill. Inadequate diking, potential pollution Environmental Health & Safety Failure to take necessary measures to prevent pollutants from directly or indirectly reaching waters of the Commonwealth.
2245762 688895 12/16/2013 2013-12-16 78.56(1) - Pit and tanks not constructed with sufficient capacity to contain pollutional substances. Administrative Failure to contain a pollutional substance in a properly lined pit or tank.
2245762 688897 12/16/2013 2013-12-16 SWMA301 - Failure to properly store, transport, process or dispose of a residual waste. Environmental Health & Safety Failure to properly store, transport, process or dispose of a residual waste.
2245762 688899 12/16/2013 2013-12-16 OGA3218.2(A) - Failure to design and construct unconventional well site to prevent spills to the ground surface and off well site. Environmental Health & Safety Containment on Unconventional Well Sites

Penalties Applied

Violation ID Penalty ID Penalty Code Penalty Status Penalty Date Enforcement Date Penalty Amount Amount Collected
688893 307632 NOV - Notice of Violation
688894 307632 NOV - Notice of Violation
688895 307632 NOV - Notice of Violation
688897 307632 NOV - Notice of Violation
688899 307632 NOV - Notice of Violation

For data sources see[9]

References