X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-115-20861

Well Details

Well ID: 37-115-20861
Loading map...
Country: United States
State: Pennsylvania
County: Susquehanna
Municipality: Springville Township
Operator Name: CABOT OIL & GAS CORP
Well Pad ID: 149402
Farm/Lease Name: T FLOWER 2
License Status:
Spud Date:
Permit Date: 2012-02-07
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.646467
Longitude: -75.961686

For data sources see[1][2][3]

Well History

Date Event
2012-02-07 New Permit Application
2012-08-11 Performed Spud Operation
2012-10-20 Drilling Completion
2012-11-01 Perforation
2012-11-09 Performed Stimulation
2014-03-13 DEVIATED

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2012-11-08 2012-11-08 7,559 12,525,280

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 ICI-3240 Fisher Technical Services Inc. (FTSI) Biocide Sodium hydroxide 1310-73-2 4.00 0.00100000
Tetrahydro-3,5-dimethyl,2H-1,3,5-thiadiazine-2-thione 533-74-4 24.00 0.00599000
Hydrochloric Acid 10.1-15 Fisher Technical Services Inc. (FTSI) Acidizing Water 7732-18-5 85.00 0.44
Hydrochloric acid 7647-01-0 15.00 0.07
CS-500 SI Fisher Technical Services Inc. (FTSI) Scale Inhibitor Ethylene glycol 107-21-1 10.00 0.00246000
Water Carrier/Base Fluid Water 7732-18-5 100.00 88.12
40/70 White Fisher Technical Services Inc. (FTSI) Proppant Crystalline Silica 100.00 10.62
CI-150 (Corrosion Inhibitor) Fisher Technical Services Inc. (FTSI) Corrosion Inhibitor Aromatic aldehyde 10.00 0.00010000
Isopropanol 67-63-0 60.00 0.00058000
Quaternary ammonium compound 10.00 0.00010000
Organic Amineresin Salt 30.00 0.00029000
N,N-Dimethylformamide 68-12-2 10.00 0.00010000
100 Mesh Fisher Technical Services Inc. (FTSI) Proppant Crystalline Silica 100.00 0.60
FRW-200 Fisher Technical Services Inc. (FTSI) Friction Reducer Distillates, petroleum, hydrotreated light 64742-47-8 26.00 0.01
FE 100L (Iron Chelator) Fisher Technical Services Inc. (FTSI) Iron Control Product Citric acid 77-92-9 55.00 0.00096000

For data sources see[5]

Stimulation Data

Stimulation Date Phase Number Chemical Agent Volume (gal) Treating Pressure (psi) Breakdown Pressure (psi)
2012-11-09 0 0 0

For data sources see[6]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2012 CABOT OIL & GAS CORP 663,697.04 22 0.00 0 0.00 0
2013 CABOT OIL & GAS CORP 8,411,155.14 365 0.00 0 0.00 0
2014 CABOT OIL & GAS CORP 4,120,721.80 358 0.00 0 0.00 0
2015 CABOT OIL & GAS CORP 3,058,998.28 365 0.00 0 0.00 0
2016 CABOT OIL & GAS CORP 2,823,233.36 366 0.00 0 0.00 0
2017 CABOT OIL & GAS CORP 1,864,296.23 365 0.00 0 0.00 0
2018 CABOT OIL & GAS CORP 698,242.00 223 0.00 0 0.00 0
2019 CABOT OIL & GAS CORP 512,777.00 351 0.00 0 0.00 0

For data sources see[7]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2012 CABOT OIL & GAS CORP Produced Fluid 2,562.79 Bbl REUSE OTHER THAN ROAD SPREADING
2012 CABOT OIL & GAS CORP Drilling Fluid Waste 1,210.00 Bbl REUSE OTHER THAN ROAD SPREADING
2012 CABOT OIL & GAS CORP Basic Sediment 20.14 Bbl LANDFILL THR029
2012 CABOT OIL & GAS CORP Fracing Fluid Waste 26,569.31 Bbl REUSE OTHER THAN ROAD SPREADING
2012 CABOT OIL & GAS CORP Fracturing Fluid Waste 46.72 Tons LANDFILL THR029
2012 CABOT OIL & GAS CORP Drill Cuttings 585.94 Tons LANDFILL 101247
2012 CABOT OIL & GAS CORP Drill Cuttings 999.40 Tons LANDFILL THR029
2012 CABOT OIL & GAS CORP Drilling Fluid Waste 1,179.54 Bbl LANDFILL THR029
2012 CABOT OIL & GAS CORP Fracing Fluid Waste 7,599.49 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NE001
2013 CABOT OIL & GAS CORP Produced Fluid 1,570.31 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NE002
2013 CABOT OIL & GAS CORP Produced Fluid 2,697.43 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2013 CABOT OIL & GAS CORP Produced Fluid 13.50 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE001
2014 CABOT OIL & GAS CORP Produced Fluid 1,580.50 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2014 CABOT OIL & GAS CORP Produced Fluid 81.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE001
2015 CABOT OIL & GAS CORP Produced Fluid 748.59 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2015 CABOT OIL & GAS CORP Produced Fluid 5.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE001
2016 CABOT OIL & GAS CORP Produced Fluid 426.88 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2016 CABOT OIL & GAS CORP Produced Fluid 445.83 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2017 CABOT OIL & GAS CORP Produced Fluid 461.55 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2017 CABOT OIL & GAS CORP Produced Fluid 309.92 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC018
2018 CABOT OIL & GAS CORP Produced Fluid 380.38 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2018 CABOT OIL & GAS CORP Other Oil & Gas Wastes 23.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2018 CABOT OIL & GAS CORP Produced Fluid 127.46 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC018
2019 CABOT OIL & GAS CORP Produced Fluid 381.61 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2019 CABOT OIL & GAS CORP Synthetic Liner Materials 4.70 Tons LANDFILL 101247
2019 CABOT OIL & GAS CORP Produced Fluid 3.87 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE004

For data sources see[8]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2105633 Primary Facility 2012-09-19 Drilling/Alteration No Violations Noted Patterson 263. Running 13 3/8" casing now. Walked site with Co. man. Secondary containment in place and in good condition. Having safety meeting while on site prior to running casing. Haliburton on standby to cement. No violations observed at this time.
2115091 Primary Facility 2012-11-07 Drilling/Alteration No Violations Noted Walked pad pre-frac suggested enhaced containment
2125271 Primary Facility 2012-12-05 Routine/Complete Inspection No Violations Noted Production crews on site. Flow back of wells is complete. Crews on site are breaking down flow back equipment. Secondary containment in place. Well tags are present. Site Id sign correct. No violations observed.
2246179 Primary Facility 2014-02-04 Incident- Response to Accident or Event Pending Arrived at the site at 13:45 in response to a spill of (15) gallons of production fluid. The spill occurred as a result of the dump line freezing.
2271279 Primary Facility 2014-05-16 Administrative/File Review Viol(s) Noted & Immediately Corrected
2691995 Primary Facility 2018-01-29 Routine/Complete Inspection No Violations Noted Arrived on location at 11:30. Accompanied by DEP OGI, Ulyana Trynovich. Weather: Clear, cold, ~ 25 degs. (2) existing wells were present and in production, the Flower, T. 1H and 2H. Both wells (13x9) and (9x5) annuli were open and venting, plumbed to a common, shared vent tank. A Gas check performed at vent tank showed 100% LEL, 20% CH4. *Due to the commingling of the (13x9) and (9x5) annular vents to these vent tanks, a follow-up inspection will need to be scheduled with Operator to check the (13x9) cemented annuli for any sustained presence of gas. Please contact me when these (13x9) vents can be separated or isolated and rechecked. (kenkennedy@pa.gov). Both wells Prod. casing, Static and Differential pressures were being monitored by wireless sending units sending data to onsite Total Flow Control Unit "TFCU". See individual well pressures and flow rates listed below:

(CP= prod. casing press., SP= static press., DP= differential press.) - 1H: CP= 573.2 psi., SP= 557.3 psi., DP= 94.2 psi. - 2H: CP= 581.2

2697689 Primary Facility 2018-02-14 Follow-up Inspection No Violations Noted Arrived on location at 08:15. Weather: Overcast, cold, ~ 32 degs. (2) existing wells were present and in production, the Flower, T. 1H and 2H. Onsite in follow up to previous insp. performed on 1/29/18. Upon arrival I met with Cabot Rep., Aaron Onks. As requested in previous inspection, Mr. Onks had isolated both wells (13x9) and (9x5) annuli and opened vents to atmosphere at ~ 8:00 this morning. Gas checks performed at these annular vents showed:

- Flower, T. 1H: (13x9): Initial check 100% LEL, 2% CH4, diminishing to a Final check of 0% LEL, 0% CH4. (9x5): 0% LEL, 0% CH4. - Flower, T. 2H: (13x9): Initial check 100% LEL, 4% CH4, diminishing to a Final check of 0% LEL, 0% CH4. (9x5): 100% LEL, 100% CH4 sustained.

  It appears the initial gas hits detected at both wells (13x9) annuli were from remnant, commingled, gas trapped within common vent lines which was sourced by the Flower, T. 2H wells (9x5) actively venting annulus. The gas venting at this (9x5) annulus is expected due to the production casing ceme
2713984 Primary Facility 2018-03-22 Drilling/Alteration No Violations Noted Matt Shope, DEP O&G WQS and I arrived at the site at 11:23 to conduct an inspection. The weather conditions were partly cloudy skies, quite breezy and cold with temps in the upper 30's. Precision Drilling Rig # 548 is at the site. Mr. Shope and I went inside of the company man trailer in search of the company man shortly after arrival. He was not inside the trailer. According to the white board on the wall in the trailer, Precision is currently drilling the T Flower 008 well at depth of (2,805.20) feet. Shortly after reviewing the board and computer screen containing information relevant to drilling of the well and reviewing drill cuttings waste manifests, Mr. Shope and I proceeded to conduct an inspection of the site. We had observed that a portion of the secondary containment liner was not secured in (3) separate areas of the site. See photos. We eventually met Marcus Cormier, site company man, consultant of Cabot. We had a brief discussion regarding our site inspection near the rig and where additional we
2723274 Primary Facility 2018-04-20 Routine/Complete Inspection No Violations Noted I was accompanied by Ken Kennedy (OGI) and Casey Baldwin (WQS/ET). Precision Drilling Rig 546 is currently operating at the site. Prior to conducting the inspection, we met with Marcus Cormir (Company Man). The 12H well was being drilled at time of the inspection. There were no violations noted. If you have any questions, please contact me.
2756222 Primary Facility 2018-07-11 Routine/Complete Inspection No Violations Noted I conducted the inspection accompanied by Jon Sassi (EPS) and Casey Baldwin (WQS/ET). At the time of the inspection, the 11H Well plugs were being drilled out, a Coil Tubing Unit was on the 6H Well, and another service rig was being prepared for the 3H Well. Additional information related to this inspection may be referenced in e-Facts Inspection ID: 2751430. If you have any questions, please contact me.
2798834 Primary Facility 2018-10-16 Incident- Response to Accident or Event Viol(s) Noted & Immediately Corrected Casey Baldwin, DEP O&GWQS out of the Scranton District Office and I arrived at the site 11:46 in response to a reported spill of an unknown volume and time of a spill of hydraulic fluid to the pad surface. The weather conditions are mostly sunny skies, breezy and brisk, with temperatures in the mid 40's. On 10/16/18 at 8:56, Brody Webster, Environmental Health and Safety Supervisor of Cabot Oil and Gas contacted me to report the spill incident. He stated the following during our phone conversation. "A well tender discovered staining on the pad surface earlier this morning , 10/16/18, as a result of a spill of hydraulic fluid. A coil tube unit recently performed clean out operations on the T Flower 2H well. Hydraulic fluid was released out of the unit and impacted the pad surface. We are not able to calculate the actual volume of the fluid released at this time, but believe it is not more than (5) gallons, and consider this a small spill. GasSearch Drilling Services (GDS) is at the site in the process of

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
2271279 695972 05/16/2014 2014-05-16 402CSL - Failure to adopt pollution prevention measures required or prescribed by DEP by handling materials that create a danger of pollution. Environmental Health & Safety Potential for pollutional substances to enter the waters of the commonwealth
2271279 695973 05/16/2014 2014-05-16 78.57 - Failure to post pit approval number Administrative Failure to collect the brine and other fluids produced during the operation and service of the well in a tank, pit or a series of pits or tanks, or other device approved by DEP.
2271279 695974 05/16/2014 2014-05-16 SWMA301 - Failure to properly store, transport, process or dispose of a residual waste. Environmental Health & Safety Failure to properly store, transport, process or dispose of a residual waste.
2798834 832614 2018-10-16 2018-10-16 CSL 402(b) Environmental Health & Safety The violation is cited due to the hydraulic fluid spill impacting the pad surface in the general vicinity of the T Flower 1H and 2H well.
2798834 832615 2018-10-16 2018-10-16 78a56(a) Environmental Health & Safety The violation is cited due to the hydraulic fluid spill impacting the pad surface in the general vicinity of the T Flower 1H and 2H well.
2798834 832616 2018-10-16 2018-10-16 SWMA 301 Environmental Health & Safety The violation is cited due to the hydraulic fluid spill impacting the pad surface in the general vicinity of the T Flower 1H and 2H well.

For data sources see[9]