Well Details

Well ID: 37-115-20706
Loading map...
Country: United States
State: Pennsylvania
County: Susquehanna
Municipality: Bridgewater Township
Operator Name: CABOT OIL & GAS CORP
Well Pad ID: 147898
Farm/Lease Name: C FRYSTAK 2
License Status:
Spud Date:
Permit Date: 2011-10-26
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.845161
Longitude: -75.910036

For data sources see[1][2][3]

Well History

Date Event
2011-10-26 New Permit Application
2011-11-04 Performed Spud Operation
2011-12-13 Drilling Completion
2012-02-02 Perforation
2012-02-02 Performed Stimulation
2012-08-17 DEVIATED

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2012-02-23 2012-02-23 6,400 8,442,672

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Sand (Proppant) Proppant 11.42
AI-2 Superior Well Services Corrosion Inhibitor Proprietary Component 7.00 0.00007000
Propargyl alcohol 107-19-7 30.00 0.00029000
2-Butoxyethanol 111-76-2 30.00 0.00029000
Isopropanol 67-63-0 30.00 0.00029000
KR-153SL Superior Well Services Biocide 2,2-Dibromo-3-nitrilopropionamide 10222-01-2 20.00 0.00551000
Ethylene glycol 107-21-1 1.00 0.00028000
Polyethylene glycol 25322-68-3 50.00 0.01
Diethylene glycol 111-46-6 3.50 0.00096000
WFR-3B Superior Well Services Friction Reducer 1,2-Propylene glycol 57-55-6 15.00 0.01
Ethoxylated alcohol blend 15.00 0.01
Poly(oxy-1,2-ethanediyl), .alpha.,.alpha.'-[[(9Z)-9-octadecenylimino]di-2,1-ethanediyl]bis[.omega.-hydroxy
-
26635-93-8 5.00 0.00388000
Distillates, petroleum, hydrotreated light 64742-47-8 50.00 0.03
Super TSC Superior Well Services Scale Control Anionic polymer 15.00 0.00369000
Anionic copolymer 15.00 0.00369000
1,2-Propylene glycol 57-55-6 40.00 0.00984000
2-Phosphonobutane-1,2,4-tricarboxylic acid, potassium salt 93858-78-7 15.00 0.00369000
Water Carrier/Base Fluid 100.00 88.38
15 HCl Superior Well Services Acid Package Hydrochloric acid 7647-01-0 15.00 0.08

For data sources see[5]

Stimulation Data

Stimulation Date Phase Number Chemical Agent Volume (gal) Treating Pressure (psi) Breakdown Pressure (psi)
2012-02-02 0 0 0

For data sources see[6]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2011 CABOT OIL & GAS CORP 0.00 0 0.00 0 0.00 0
2012 CABOT OIL & GAS CORP 403,503.16 90 0.00 0 0.00 0
2013 CABOT OIL & GAS CORP 1,001,634.44 365 0.00 0 0.00 0
2014 CABOT OIL & GAS CORP 528,040.99 363 0.00 0 0.00 0
2015 CABOT OIL & GAS CORP 392,856.45 365 0.00 0 0.00 0
2016 CABOT OIL & GAS CORP 551,996.75 366 0.00 0 0.00 0
2017 CABOT OIL & GAS CORP 509,914.20 365 0.00 0 0.00 0
2018 CABOT OIL & GAS CORP 402,648.00 365 0.00 0 0.00 0
2019 CABOT OIL & GAS CORP 406,502.00 359 0.00 0 0.00 0

For data sources see[7]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2011 CABOT OIL & GAS CORP Drilling Fluid Waste 1,595.88 Bbl REUSE OTHER THAN ROAD SPREADING
2011 CABOT OIL & GAS CORP Drill Cuttings 0.83 Tons LANDFILL 101534
2011 CABOT OIL & GAS CORP Drill Cuttings 7.23 Tons LANDFILL 101247
2011 CABOT OIL & GAS CORP Drill Cuttings 1,346.23 Tons LANDFILL THR029
2011 CABOT OIL & GAS CORP Drill Cuttings 3.55 Tons LANDFILL 100081
2012 CABOT OIL & GAS CORP Fracturing Fluid Waste 49.39 Tons LANDFILL 101534
2012 CABOT OIL & GAS CORP Produced Fluid 4,990.15 Bbl REUSE OTHER THAN ROAD SPREADING
2012 CABOT OIL & GAS CORP Basic Sediment 38.61 Bbl LANDFILL THR029
2012 CABOT OIL & GAS CORP Fracturing Fluid Waste 14.08 Tons LANDFILL 100081
2012 CABOT OIL & GAS CORP Fracing Fluid Waste 17,720.86 Bbl REUSE OTHER THAN ROAD SPREADING
2012 CABOT OIL & GAS CORP Fracturing Fluid Waste 12.67 Tons LANDFILL 100945
2012 CABOT OIL & GAS CORP Produced Fluid 378.96 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NE001
2013 CABOT OIL & GAS CORP Produced Fluid 7,532.52 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NE002
2013 CABOT OIL & GAS CORP Produced Fluid 4,700.52 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2013 CABOT OIL & GAS CORP Produced Fluid 95.56 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NE001
2013 CABOT OIL & GAS CORP Produced Fluid 29.50 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE001
2014 CABOT OIL & GAS CORP Produced Fluid 4,066.42 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2014 CABOT OIL & GAS CORP Produced Fluid 39.83 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE001
2015 CABOT OIL & GAS CORP Produced Fluid 1,550.54 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2015 CABOT OIL & GAS CORP Produced Fluid 24.60 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE001
2016 CABOT OIL & GAS CORP Synthetic Liner Materials 1.04 Tons LANDFILL 101247
2016 CABOT OIL & GAS CORP Produced Fluid 1,378.06 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC018
2016 CABOT OIL & GAS CORP Produced Fluid 2,122.16 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2016 CABOT OIL & GAS CORP Produced Fluid 795.30 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2017 CABOT OIL & GAS CORP Produced Fluid 61.53 Bbl REUSE (AT WELL PAD)
2017 CABOT OIL & GAS CORP Produced Fluid 3,449.62 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC018
2017 CABOT OIL & GAS CORP Produced Fluid 630.97 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2018 CABOT OIL & GAS CORP Produced Fluid 87.13 Bbl REUSE (AT WELL PAD)
2018 CABOT OIL & GAS CORP Produced Fluid 1,847.94 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2018 CABOT OIL & GAS CORP Produced Fluid 1,335.78 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC018
2019 CABOT OIL & GAS CORP Produced Fluid 3,823.37 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2019 CABOT OIL & GAS CORP Produced Fluid 55.16 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE004

For data sources see[8]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2027665 Primary Facility 2011-12-06 Drilling/Alteration Violation(s) Noted H&P 371. Currently drilling @ depth of 9150'. Drillers log on site and up to date. Secondary containment in place. Followed up on 3 reported spills of drilling mud. 2 spills due to mechanical failures. Both spills on plastic. 3rd spill located behind mud loggers shack. Approximately 2 gallons SOBM. Tank overfilled. Tank used for holding fluid from washing samples. Operator has cleaned up visual spilled material and collecting samples from impacted area. Operator installing better berm around tank Violations cited.
2058724 Primary Facility 2012-04-05 Follow-up Inspection No Violations Noted Follow up on complaint of strong petroleum odor coming from location. Reported that 4 flares were beurning and a very potent odor detected. At time of inspection flaring shut down 5 pm on 5/4/12 according to operator. Were recently flowing back 2H, 3H 5H and 7H. All have been completed. Will be breaking down equipment tomorrow. No more flaring or flowback will be performed at this time. While on site, there was no flaring, and no petroleum odor observed.
2369286 Primary Facility 2015-05-13 Routine/Complete Inspection No Violations Noted
2435954 Primary Facility 2015-12-28 Routine/Complete Inspection No Violations Noted At time of inspection, arrived on site at 11:00 a.m., the cellar was about a quarter full of water with no bubbling observed, the (13x9) vent pipe was open and venting to a tank, the (9x5) vent pipe was open and venting to a tank, there was 664psi on the production casing. I took a walk around the location and everything looked OK.
2438946 Primary Facility 2016-01-07 Routine/Complete Inspection No Violations Noted Inspection of the well pad in conjunction with the Corporate Pipeline notice of termination inspection. No issues observed on the well pad.
2496241 Primary Facility 2016-06-24 Site Restoration No Violations Noted Inspection of the Frystak C P1 Well Pad in response to a submitted Notice of Termination request for the Erosion and Sedimentation Control Permit.

The site has been stabilized and vegetation was found to be greater than 70% uniform perennial growth. Temporary E&S BMPs have been removed from the site. No E&S problems were observed at the time of the inspection. The restored pad size is consistent with the PCSM/Site Restoration Plan. Post construction storm water management devices were in place according to approved plans and appear to be functioning properly.

Based on the site inspection, I recommend this notice of termination be APPROVED.

2534019 Primary Facility 2016-11-01 Routine/Complete Inspection No Violations Noted At time of inspection, arrived on site at 13:40p.m., the cellar had water at the bottom with no bubbling noticed. The (13x9) vent pipe was open and venting into a tank, the (9x5) vent pipe was open and venting into a tank. There was 612psi on the production casing. I took a walk around the location and there were no obvious concerns noticed.

I left the site at 14:15p.m.

2560661 Primary Facility 2017-01-27 Incident- Response to Accident or Event No Violations Noted Steve Watson, Environmental Health and Safety Specialist of Cabot Oil and Gas contacted me on 1/27/17 at 10:11 AM to report a spill of antifreeze (glycol) that occurred on 1/27/17 around 9:00 AM. He stated the following during our phone conversation. "An antifreeze line failed on a GasSearch Drilling Services Water Truck picking up production fluid, spilling 5.5 gallons of antifreeze to the pad surface. The hose has been repaired in the truck and the tank has been refilled with antifreeze. The spill happened around 9AM. I was notified at 9:15 AM. Resource Environmental is on the way to assess the spill and screen the impacted area. A backhoe and a roll-off container are either already there or in-route. The spill is considered a small spill. Samples will not be collected. The impacted material will either be transported for disposal to Waste Recovery Solutions in Myerstown, PA or Tunnel Hill Reclamation Landfill in New Lexington, Ohio."

Briana Cunningham, DEP O&G WQS and I arrived at the site at 12:40

2568328 Primary Facility 2017-02-23 Routine/Complete Inspection No Violations Noted The Department was on site at the C Frystak Well Site to conduct a Routine Complete Inspection. I reviewed the E&S Inspection Log which read that Mike Brilla (TEC) conducted the most recent inspection on 11-29-16 and it was a PCSM Inspection. The site has been restored.
2621643 Primary Facility 2017-08-02 Routine/Complete Inspection No Violations Noted At time of inspection, arrived on site at 11:45a.m.

The cellar had water at the bottom with no bubbling noticed. The (13x9) annulus vent pipe was open and venting into a small plastic tank, the (9x5) annulus vent pipe was open and venting into a small plastic tank. All the annulus vent pipes were connected to one pipe going into the same tank. There was 620psi on the production casing and 477psi on the production line. I took a walk around the location and there were no obvious concerns noticed. I left the site at 12:30p.m.

2730093 Primary Facility 2018-05-15 Routine/Complete Inspection No Violations Noted At time of inspection.

The well was in production. There was water 3' below grade in the cellar and there was no bubbling noticed, there was no gas detected in the remainder of the cellar. The (13x9) and (9x5) annuli vent pipes were connected together and venting to the same tank. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted.

2827625 Primary Facility 2019-01-16 Routine/Complete Inspection No Violations Noted At time of inspection.

The well was in production. There was ice 4' below grade in the cellar and there was no gas detected in the remainder of the cellar with a MSA Altair 5X multi gas detector that was calibrated on 1/2/19. The (13x9) and (9x5) annuli vent pipes were connected together and going to the same poly vent tank. There was gas detected at the poly vent tank with a MSA Altair 5X multi gas detector that was calibrated on 1/2/19. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted.

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
2027665 627176 12/06/2011 2011-12-06 78.54* - Failure to properly control or dispose of industrial or residual waste to prevent pollution of the waters of the Commonwealth. Environmental Health & Safety
2027665 627177 12/06/2011 2011-12-06 78.56(1) - Pit and tanks not constructed with sufficient capacity to contain pollutional substances. Administrative

For data sources see[9]