X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-115-20515

Well Details

Well ID: 37-115-20515
Loading map...
Country: United States
State: Pennsylvania
County: Susquehanna
Municipality: Forest Lake Township
Operator Name: CABOT OIL & GAS CORP
Well Pad ID: 148592
Farm/Lease Name: J HAWLEY 3
License Status:
Spud Date:
Permit Date: 2011-03-10
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.862739
Longitude: -75.964433

For data sources see[1][2][3]

Well History

Date Event
2011-03-10 New Permit Application
2011-09-06 Performed Spud Operation
2011-10-17 Drilling Completion
2011-11-22 Perforation
2011-11-22 Performed Stimulation
2012-06-22 DEVIATED

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2011-12-06 2011-12-06 6,396 4,672,542

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Super TSC Superior Well Services Scale Control 2-Phosphonobutane-1,2,4-tricarboxylic acid, potassium salt 93858-78-7 15.00 0.00366000
Anionic copolymer 15.00 0.00366000
Anionic polymer 15.00 0.00366000
1,2-Propylene glycol 57-55-6 40.00 0.00976000
AI-2 Superior Well Services Corrosion Inhibitor Proprietary Component 7.00 0.00008000
2-Butoxyethanol 111-76-2 30.00 0.00033000
Propargyl alcohol 107-19-7 30.00 0.00033000
Isopropanol 67-63-0 30.00 0.00033000
WFR-3B Superior Well Services Friction Reducer Poly(oxy-1,2-ethanediyl), .alpha.,.alpha.'-[[(9Z)-9-octadecenylimino]di-2,1-ethanediyl]bis[.omega.-hydroxy
-
26635-93-8 5.00 0.00344000
Distillates, petroleum, hydrotreated light 64742-47-8 50.00 0.03
Ethoxylated alcohol blend 15.00 0.01
1,2-Propylene glycol 57-55-6 15.00 0.01
Water Carrier/Base Fluid 100.00 89.14
KR-153SL Superior Well Services Biocide Polyethylene glycol 25322-68-3 50.00 0.01
Diethylene glycol 111-46-6 3.50 0.00096000
Ethylene glycol 107-21-1 1.00 0.00027000
2,2-Dibromo-3-nitrilopropionamide 10222-01-2 20.00 0.00547000
Sand (Proppant) Proppant 10.65
15 HCl Superior Well Services Acid Package Hydrochloric acid 7647-01-0 15.00 0.09

For data sources see[5]

Stimulation Data

Stimulation Date Phase Number Chemical Agent Volume (gal) Treating Pressure (psi) Breakdown Pressure (psi)
2011-11-22 0 0 0

For data sources see[6]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2011 CABOT OIL & GAS CORP 0.00 0 0.00 0 0.00 0
2012 CABOT OIL & GAS CORP 961,102.75 346 0.00 0 0.00 0
2013 CABOT OIL & GAS CORP 744,944.42 365 0.00 0 0.00 0
2014 CABOT OIL & GAS CORP 409,177.02 364 0.00 0 0.00 0
2015 CABOT OIL & GAS CORP 282,312.90 365 0.00 0 0.00 0
2016 CABOT OIL & GAS CORP 410,087.82 350 0.00 0 0.00 0
2017 CABOT OIL & GAS CORP 392,825.54 365 0.00 0 0.00 0
2018 CABOT OIL & GAS CORP 291,392.00 365 0.00 0 0.00 0
2019 CABOT OIL & GAS CORP 248,037.00 365 0.00 0 0.00 0

For data sources see[7]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2011 CABOT OIL & GAS CORP Drilling Fluid Waste 453.16 Bbl REUSE OTHER THAN ROAD SPREADING
2011 CABOT OIL & GAS CORP Drill Cuttings 1,435.22 Tons LANDFILL THR029
2011 CABOT OIL & GAS CORP Drill Cuttings 1.24 Tons LANDFILL 100081
2012 CABOT OIL & GAS CORP Fracturing Fluid Waste 3.86 Tons LANDFILL 101534
2012 CABOT OIL & GAS CORP Basic Sediment 37.00 Bbl LANDFILL 101534
2012 CABOT OIL & GAS CORP Produced Fluid 5,709.74 Bbl REUSE OTHER THAN ROAD SPREADING
2012 CABOT OIL & GAS CORP Basic Sediment 18.37 Bbl LANDFILL THR029
2012 CABOT OIL & GAS CORP Fracturing Fluid Waste 23.42 Tons LANDFILL 100081
2012 CABOT OIL & GAS CORP Fracing Fluid Waste 7,471.61 Bbl REUSE OTHER THAN ROAD SPREADING
2012 CABOT OIL & GAS CORP Fracturing Fluid Waste 8.17 Tons LANDFILL 100945
2012 CABOT OIL & GAS CORP Basic Sediment 6.56 Bbl LANDFILL 100081
2012 CABOT OIL & GAS CORP Produced Fluid 95.71 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NE001
2013 CABOT OIL & GAS CORP Produced Fluid 1,843.37 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NE002
2013 CABOT OIL & GAS CORP Produced Fluid 1,424.26 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2013 CABOT OIL & GAS CORP Produced Fluid 100.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE001
2014 CABOT OIL & GAS CORP Produced Fluid 1,212.59 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2014 CABOT OIL & GAS CORP Produced Fluid 18.33 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE001
2015 CABOT OIL & GAS CORP Produced Fluid 605.86 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2016 CABOT OIL & GAS CORP Produced Fluid 487.91 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC018
2016 CABOT OIL & GAS CORP Produced Fluid 650.80 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2016 CABOT OIL & GAS CORP Produced Fluid 245.69 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2017 CABOT OIL & GAS CORP Produced Fluid 159.79 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2017 CABOT OIL & GAS CORP Produced Fluid 20.44 Bbl REUSE (AT WELL PAD)
2017 CABOT OIL & GAS CORP Produced Fluid 1,600.76 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC018
2018 CABOT OIL & GAS CORP Produced Fluid 25.95 Bbl REUSE (AT WELL PAD)
2018 CABOT OIL & GAS CORP Produced Fluid 1,038.95 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2018 CABOT OIL & GAS CORP Produced Fluid 765.32 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC018
2019 CABOT OIL & GAS CORP Produced Fluid 1,728.34 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2019 CABOT OIL & GAS CORP Produced Fluid 7.88 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE004

For data sources see[8]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2143139 Primary Facility 2011-09-20 Drilling/Alteration No Violations Noted At the time of inspection, Patterson 538 on site currently drilling J. Hawley 2H. Drilling on air ..and expect to be running 9 5/8 casing in the next 24 hrs. Conductor has been set for J Hawley 3H at depth of 101'. J Hawley 3 is scheduled to be next well drilled on pad. No violations observed at this time.
2335264 Primary Facility 2015-01-09 Routine/Complete Inspection No Violations Noted The Department was on site at the Hawley J, Pad 1. to perform a Routine Complete Inspection. The wells on this site are the 2H, 3H, 4H, 5H, 6H and 7H. The Numbers, respectively, are 115-20516, 20515, 20560, 20518, 20561, and 20463. The site's last E&S inspection was on 1-7-2015. The site was adequately vegetated and stable. There were no violations.
2377237 Primary Facility 2015-06-04 Routine/Complete Inspection No Violations Noted The Department was on site to conduct a routine complete inspection of the erosion and sedimentation controls at the J. Hawley well pad (ESX10-115-0061) on June 4, 2015. The wells associated with this pad are as follows:
2407820 Primary Facility 2015-09-17 Routine/Complete Inspection No Violations Noted
2505637 Primary Facility 2016-07-28 Routine/Complete Inspection No Violations Noted At time of inspection, arrived on site at 8:55a.m., the cellar was about three quarters full of water with no bubbling noticed, the (13x9) vent pipe was open and venting into a tank, the (9x5) vent pipe was open and venting into a tank, there was 561psi on the production casing. There was a crew doing remedial work on the lower side of the location, I took a walk around the location and everything looked OK.

I left the site at 9:50a.m.

2549836 Primary Facility 2017-01-05 Routine/Complete Inspection No Violations Noted The Department was on site to conduct a routine complete inspection of the erosion and sedimentation controls for the at the J. Hawley well pad (ESX10-115-0061) on June 4, 2015. The wells associated with this pad are as follows:

5H 115-20518 6H 115-20561 7H 115-20463 2H 115-20516 3H 115-20515 4H 115-20560

The site was in production, and not under any major construction. and the site was very well vegetated (>70%) and graded well. There were no erosion and sedimentation issues on site and the access road was holding up well.


There were no violations

If there are any questions please feel free to contact me at (570)346-5539

2600895 Primary Facility 2017-06-01 Routine/Complete Inspection No Violations Noted At time of inspection, arrived on site at 14:05p.m.

The cellar was full of water with no bubbling noticed. The (13x9) annulus vent pipe was open and venting into a small plastic tank, the (9x5) annulus vent pipe was open and venting into a small plastic tank. There was 536psi on the production casing and 482psi on the production line. I took a walk around the location and there were no obvious concerns noticed. I left the site at 14:45p.m.

2648765 Primary Facility 2017-10-18 Routine/Complete Inspection No Violations Noted I inspected the J. Hawley pad for Notice of Termination on October 3, 2017. The site was well constructed and had no apparent erosional problems. The vegetation was at or exceeding 70%.

There were no violations noted.

I recommend APPROVAL of this NOT.

2709551 Primary Facility 2018-03-16 Routine/Complete Inspection No Violations Noted At time of inspection.

The well was in production. There was water and ice .5' below grade in the cellar and there was no bubbling noticed. The (13x9) and (9x5) annuli vent pipes were connected together and going to the same tank. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted.

2710094 Primary Facility 2018-03-26 Routine/Complete Inspection No Violations Noted I inspected the J. Hawley well pad on March 26, 2018. It was sunny and about 38 degrees out. The access road was solid and the pad surface was partly snow covered yet stable. The cut and fill slopes were not steep and were well vegetated. The wells associated with the site are as follows:

115-20515 115-20516 115-20518 115-20560 115-20561 115-20563

There were no apparent erosional issues. There were no violations noted.

2808814 Primary Facility 2018-11-30 Routine/Complete Inspection No Violations Noted At time of inspection.

The well was in production. The cellar was full of water and there was no bubbling noticed. The (13x9) and (9x5) annuli vent pipes were connected together and going to the same poly vent tank. There was gas detected at the poly vent tank with a MSA Altair 5X multi gas detector that was calibrated on 11/2/18. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted.

For data sources see[9]

References