37-115-20427

Well Details

Well ID: 37-115-20427
Loading map...
Country: United States
State: Pennsylvania
County: Susquehanna
Municipality: Springville Township
Operator Name: CHIEF OIL & GAS LLC
Well Pad ID: 149338
Farm/Lease Name: SQUIER UNIT 1H
License Status:
Spud Date:
Permit Date: 2010-08-13
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.671611
Longitude: -75.855472

For data sources see[1][2][3]

Well History

Date Event
2010-08-13 New Permit Application
2010-09-19 Performed Spud Operation
2010-10-08 Drilling Completion
2012-06-01 Perforation
2012-06-01 Performed Stimulation
2013-05-23 DEVIATED

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2011-05-31 2011-05-31 7,580 990,234
2 2012-05-18 2012-05-18 7,580 3,392,046

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Unislik ST 50 Universal Well Services Friction Reducer Distillates, petroleum, hydrotreated light 64742-47-8 0.09
Biocide EC 6116A Universal Well Services Biocide 2,2-Dibromo-3-nitrilopropionamide 10222-01-2
Dibromoacetonitrile 3252-43-5 0.02
Polyethylene glycol 25322-68-3
Sand (Proppant) Universal Well Services Propping Agent Quartz 14808-60-7 99.90 14.81
Water Base Fluid Water 100.00 85.00
ScaleHib 100 Universal Well Services Scale Inhibitor Ethylene glycol 107-21-1 0.04
FE OXCLEAR Universal Well Services Oxygen Scavenger Ammonium bisulfite 10192-30-0 0.01
2 Unislik ST 50 Universal Well Services Friction Reducer
Distillates, petroleum, hydrotreated light 64742-47-8 0.09
Fresh Water Base Fluid Fresh Water 100.00 76.97
Biocide - Bactron K 139 Champion Technologies Biocide Ethanol 64-17-5
benzyl-C12-16 alkyldimethyl,chlorides
Quaternary ammonium compounds,
benzyl-C12-16-alkyldimethyl, chlorides
68424-85-1
Glutaraldehyde 111-30-8 0.03
Water Base Fluid Water 100.00 84.39
Hydrochloric Acid 15 Universal Well Services Acid Hydrochloric acid 7647-01-0 0.62
Hydrochloric acid 7647-01-0 0.61
Water 7732-18-5
Hydrochloric Acid 15 Frac Tech Services (FTS) Acid
Scale Inhibitor - Gyptron T-390 Champion Technologies Scale Inhibitor
Methanol 67-56-1 0.00900000
FE OXCLEAR Universal Well Services Oxygen Scavenger Ammonium bisulfite 10192-30-0 0.01
FRW-600 Frac Tech Services (FTS) Friction Reducer
Distillates, petroleum, hydrotreated light 64742-47-8 0.06
Sand (Proppant) Universal Well Services Propping Agent
Sand (Proppant) Frac Tech Services (FTS) Propping Agent
Quartz 14808-60-7 99.90 14.82
Quartz 14808-60-7 99.90 22.30
Biocide EC 6116A Universal Well Services Biocide Polyethylene glycol 25322-68-3
2,2-Dibromo-3-nitrilopropionamide 10222-01-2
Dibromoacetonitrile 3252-43-5 0.02
ScaleHib 100 Universal Well Services Scale Inhibitor Ethylene glycol 107-21-1 0.04

For data sources see[5]

Stimulation Data

Stimulation Date Phase Number Chemical Agent Volume (gal) Treating Pressure (psi) Breakdown Pressure (psi)
2012-06-01 0 0 0

For data sources see[6]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2010 CHIEF OIL & GAS LLC 0.00 0 0.00 0 0.00 0
2011 CHIEF OIL & GAS LLC 168,831.00 46 0.00 0 0.00 0
2012 CHIEF OIL & GAS LLC 1,671,967.81 272 0.00 0 0.00 0
2013 CHIEF OIL & GAS LLC 1,475,084.00 362 0.00 0 0.00 0
2014 CHIEF OIL & GAS LLC 785,349.00 363 0.00 0 0.00 0
2015 CHIEF OIL & GAS LLC 441,265.26 319 0.00 0 0.00 0
2016 CHIEF OIL & GAS LLC 520,230.30 365 0.00 0 0.00 0
2017 CHIEF OIL & GAS LLC 529,376.23 364 0.00 0 0.00 0
2018 CHIEF OIL & GAS LLC 529,254.31 365 0.00 0 0.00 0
2019 CHIEF OIL & GAS LLC 403,389.51 365 0.00 0 0.00 0

For data sources see[7]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2011 CHIEF OIL & GAS LLC Fracing Fluid Waste 4,068.00 Bbl REUSE OTHER THAN ROAD SPREADING
2012 CHIEF OIL & GAS LLC Produced Fluid 1,270.80 Bbl REUSE OTHER THAN ROAD SPREADING
2012 CHIEF OIL & GAS LLC Fracing Fluid Waste 4,359.00 Bbl REUSE OTHER THAN ROAD SPREADING
2013 CHIEF OIL & GAS LLC Produced Fluid 536.90 Bbl REUSE OTHER THAN ROAD SPREADING
2014 CHIEF OIL & GAS LLC Produced Fluid 73.50 Bbl REUSE OTHER THAN ROAD SPREADING
2015 CHIEF OIL & GAS LLC Produced Fluid 46.65 Bbl REUSE OTHER THAN ROAD SPREADING
2016 CHIEF OIL & GAS LLC Produced Fluid 158.76 Bbl REUSE OTHER THAN ROAD SPREADING
2017 CHIEF OIL & GAS LLC Produced Fluid 103.51 Bbl STORAGE PENDING DISPOSAL OR REUSE
2018 CHIEF OIL & GAS LLC Produced Fluid 17.51 Bbl REUSE (AT WELL PAD)
2019 CHIEF OIL & GAS LLC Produced Fluid 5.74 Tons LANDFILL 301358

For data sources see[8]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1912907 Primary Facility 2010-09-14 Routine/Complete Inspection No Violations Noted No activity on site. conductor set and cellar cemented. Drillers log left in mailbox by Ziegenfuss. Reported 1" stream H20 at 90' and 1 3/4" stream at 115'. Mousehole drilled. Both pipes have metal plates welded over them. Planning on moving in big rig later in week.
1914993 Primary Facility 2010-09-21 Drilling/Alteration No Violations Noted Patterson 251. Drilling 12 1/4" hole to 1800' and then setting 9 5/8". Drillers log on site and up to date. Secondary containment in good condition. No pit- using closed loop system. No violations observed.
1918668 Primary Facility 2010-10-07 Drilling/Alteration No Violations Noted Pat. Rig 251. Drling depth @ TD = 10646', Setting 5 1/2" at 10613'. Haliburton on site to do cement job. Will bring cement back up into surface string. Have Ziegenfuss coming on site tomorrow to spud 2H well.
1973714 Primary Facility 2011-05-13 Routine/Complete Inspection Violation(s) Noted
2016187 Primary Facility 2011-11-02 Drilling/Alteration No Violations Noted Complete Fluid Control on site. Performing clean out run. Drilling out ice-plugs. Only well on site that has been fracced so far. Secondary containment in place. No violations observed.
2035225 Primary Facility 2012-01-17 Routine/Complete Inspection No Violations Noted
2062242 Primary Facility 2012-04-17 Incident- Response to Accident or Event Pending
2316775 Primary Facility 2014-10-16 Complaint Inspection Pending The Department (Andrea Mullen, Eric Rooney, Jon Sassi, and I) met with Jon Hafer (Chief Oil & Gas) on site at the Squier Unit Well Site to collect soil samples in response to a nearby water quality complaint. The Department collected the below referenced samples to be analyzed with the SAC 961 with the addition of sulfates, lead, calcium, bromide dry weight, and lithium :
2549606 Primary Facility 2016-01-04 Routine/Partial Inspection No Violations Noted
2729092 Primary Facility 2018-04-17 Follow-up Inspection No Violations Noted The Department was on site to meet with representatives of Chief Oil & Gas to conduct a Follow Up Inspection to the Department's 4/17/2012 inspection which was conducted in response to a self-reported and assumed vandalism incident causing the release of an approximate 500 bbl. of what was reported to be freshwater to the pad's surface. During the inspection conductivity screening revealed elevated readings in the perimeter ditch (Collection Ditch #1) and sediment trap below the location of the release. Additionally, dead amphibians were found within the confines of said sediment trap. A copy of the sample collected during the 4/17/2012 inspection is attached for your reference.

During this inspection, Eric Rooney (DEP-PG) and I met with Mike Walor (Woodard and Curran-Scientist) and Kellon Balum (Chief). At this time, Mr. Walor began to use an auger and a shovel to reach a depth of approximately 28" so that samples collected would be from the base of the sediment trap. The material was soft and water

2741763 Primary Facility 2018-06-15 Administrative/File Review No Violations Noted On 5/16/2018 the Department received an email from Richard Adams regarding the sample results from the 4/17/2018 sampling event at the Squier A Well Site. Chief Oil & Gas submitted a Field Sampling Plan to the Department on October 4, 2017 detailing their plan. Strontium and chloride were non-detect in any of the four samples (excluding background samples). Specific conductance was measured between 118-572 in the four samples associated with the sediment trap. Barium was detected below the MSC for soils at all sample points. At this time, the Department acknowledges the sample results and will resolve the pending inspection dated 4/17/2012.
2822312 Primary Facility 2018-12-26 Routine/Complete Inspection No Violations Noted I arrived on site at 1450 to perform a site restoration inspection.

After performing an administrative review of the plan and a site inspection, I do not agree that site conditions meet the requirements for the termination of this permit. Namely, the site did not meet 70 percent vegetative cover stabilization requirements for permit termination, and the footprint restored pad did not match the site plan.

No violations were noted.

2822870 Primary Facility 2018-12-26 Routine/Complete Inspection No Violations Noted I arrived on site at 1450 to perform a site restoration inspection.

After performing an administrative review of the plan and a site inspection, I do not agree that site conditions meet the requirements for the termination of this permit. Namely, the site did not meet the 70 percent perennial vegetative cover stabilization requirements for permit termination, and the footprint of the restored pad did not match the site plan.

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
1973714 611307 05/13/2011 2011-05-13 102.4 - Failure to minimize accelerated erosion, implement E&S plan, maintain E&S controls. Failure to stabilize site until total site restoration under OGA Sec 206(c)(d) Environmental Health & Safety
1973714 611308 05/13/2011 2011-05-13 78.53* - Failure to implement and maintain BMPs in accordance with Chapter 102. Administrative

For data sources see[9]

References