If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-115-20284 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.751081,"lon":-75.867808,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Susquehanna | |
Municipality: Dimock Township | |
Operator Name: CABOT OIL & GAS CORP | |
Well Pad ID: 148440 | |
Farm/Lease Name: GREENWOOD 8 | |
License Status: | |
Spud Date: | |
Permit Date: 2010-03-17 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: No | |
Latitude: 41.751081 | |
Longitude: -75.867808 |
Date | Event |
---|---|
2010-03-17 | New Permit Application |
2010-05-05 | Performed Spud Operation |
2010-06-01 | Drilling Completion |
2010-06-13 | Perforation |
2010-08-18 | Performed Stimulation |
2011-01-25 | DEVIATED |
For data sources see[4]
Stimulation Date | Phase Number | Chemical Agent | Volume (gal) | Treating Pressure (psi) | Breakdown Pressure (psi) |
---|---|---|---|---|---|
2010-08-18 | 0 | 0 | 0 |
For data sources see[5]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2010 | CABOT OIL & GAS CORP | 1,473,734.00 | 122 | 0.00 | 0 | 0.00 | 0 |
2011 | CABOT OIL & GAS CORP | 2,566,467.41 | 347 | 0.00 | 0 | 0.00 | 0 |
2012 | CABOT OIL & GAS CORP | 1,216,366.88 | 365 | 0.00 | 0 | 0.00 | 0 |
2013 | CABOT OIL & GAS CORP | 970,890.16 | 365 | 0.00 | 0 | 0.00 | 0 |
2014 | CABOT OIL & GAS CORP | 785,652.72 | 355 | 0.00 | 0 | 0.00 | 0 |
2015 | CABOT OIL & GAS CORP | 303,080.48 | 365 | 0.00 | 0 | 0.00 | 0 |
2016 | CABOT OIL & GAS CORP | 676,524.00 | 366 | 0.00 | 0 | 0.00 | 0 |
2017 | CABOT OIL & GAS CORP | 505,012.60 | 365 | 0.00 | 0 | 0.00 | 0 |
2018 | CABOT OIL & GAS CORP | 463,214.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2019 | CABOT OIL & GAS CORP | 326,711.00 | 306 | 0.00 | 0 | 0.00 | 0 |
For data sources see[6]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2010 | CABOT OIL & GAS CORP | Fracing Fluid Waste | 9,916.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2010 | CABOT OIL & GAS CORP | Drilling Fluid Waste | 262.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR119 |
2010 | CABOT OIL & GAS CORP | Produced Fluid | 1,855.75 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2010 | CABOT OIL & GAS CORP | Basic Sediment | 2.96 Bbl | LANDFILL | 101534 |
2010 | CABOT OIL & GAS CORP | Drilling Fluid Waste | 157.70 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0101508 |
2010 | CABOT OIL & GAS CORP | Drill Cuttings | 79.30 Tons | CENTRALIZED TREATMENT PLANT FOR RECYCLE | 101247 |
2010 | CABOT OIL & GAS CORP | Drill Cuttings | 22.40 Tons | LANDFILL | NY # 50S08 |
2010 | CABOT OIL & GAS CORP | Drill Cuttings | 129.10 Tons | CENTRALIZED TREATMENT PLANT FOR RECYCLE | 8-4630-00010/00 |
2010 | CABOT OIL & GAS CORP | Drill Cuttings | 129.10 Tons | LANDFILL | NY # 02S17 |
2010 | CABOT OIL & GAS CORP | Drill Cuttings | 1.70 Tons | LANDFILL | 100955 |
2011 | CABOT OIL & GAS CORP | Drilling Fluid Waste | 524.98 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2011 | CABOT OIL & GAS CORP | Drill Cuttings | 0.64 Tons | LANDFILL | 101534 |
2011 | CABOT OIL & GAS CORP | Fracing Fluid Waste | 1.32 Bbl | LANDFILL | 301626 |
2011 | CABOT OIL & GAS CORP | Drill Cuttings | 4.03 Tons | LANDFILL | 101247 |
2011 | CABOT OIL & GAS CORP | Drilling Fluid Waste | 9.42 Bbl | LANDFILL | 301626 |
2011 | CABOT OIL & GAS CORP | Drilling Fluid Waste | 11.67 Bbl | LANDFILL | 100955 |
2011 | CABOT OIL & GAS CORP | Drill Cuttings | 54.57 Tons | LANDFILL | THR029 |
2011 | CABOT OIL & GAS CORP | Basic Sediment | 10.15 Bbl | LANDFILL | 101534 |
2011 | CABOT OIL & GAS CORP | Drilling Fluid Waste | 6.87 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PAD014286009 |
2011 | CABOT OIL & GAS CORP | Produced Fluid | 1,767.11 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2011 | CABOT OIL & GAS CORP | Drill Cuttings | 4.35 Tons | LANDFILL | 132310 |
2011 | CABOT OIL & GAS CORP | Drill Cuttings | 0.82 Tons | LANDFILL | 100081 |
2011 | CABOT OIL & GAS CORP | Drilling Fluid Waste | 5.04 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | |
2011 | CABOT OIL & GAS CORP | Drill Cuttings | 11.64 Tons | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PAD014286009 |
2012 | CABOT OIL & GAS CORP | Produced Fluid | 1,066.82 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2012 | CABOT OIL & GAS CORP | Basic Sediment | 2.21 Bbl | LANDFILL | THR029 |
2012 | CABOT OIL & GAS CORP | Basic Sediment | 2.82 Bbl | LANDFILL | 100081 |
2012 | CABOT OIL & GAS CORP | Basic Sediment | 6.55 Bbl | LANDFILL | 101534 |
2012 | CABOT OIL & GAS CORP | Produced Fluid | 14.84 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NE001 |
2013 | CABOT OIL & GAS CORP | Produced Fluid | 315.88 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NE002 |
2013 | CABOT OIL & GAS CORP | Produced Fluid | 154.83 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE002 |
2014 | CABOT OIL & GAS CORP | Produced Fluid | 190.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE002 |
2014 | CABOT OIL & GAS CORP | Produced Fluid | 60.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE001 |
2015 | CABOT OIL & GAS CORP | Produced Fluid | 185.59 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE002 |
2015 | CABOT OIL & GAS CORP | Produced Fluid | 4.25 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE001 |
2016 | CABOT OIL & GAS CORP | Produced Fluid | 209.59 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE002 |
2016 | CABOT OIL & GAS CORP | Produced Fluid | 192.46 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE002 |
2017 | CABOT OIL & GAS CORP | Produced Fluid | 209.77 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE002 |
2017 | CABOT OIL & GAS CORP | Produced Fluid | 150.35 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC018 |
2018 | CABOT OIL & GAS CORP | Produced Fluid | 270.67 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE002 |
2018 | CABOT OIL & GAS CORP | Produced Fluid | 165.04 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC018 |
2019 | CABOT OIL & GAS CORP | Produced Fluid | 273.11 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE002 |
2019 | CABOT OIL & GAS CORP | Servicing Fluid | 1.79 Tons | LANDFILL | 100933 |
2019 | CABOT OIL & GAS CORP | Servicing Fluid | 200.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC018 |
For data sources see[7]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
1886580 | Primary Facility | 2010-05-13 | Drilling/Alteration | Viol(s) Noted & Immediately Corrected | Patterson 252. Surface casing set and cemented. Crew getting ready to drill out 9 5/8" shoe. Closed loop system. All cuttings being direct loaded for disposal. BOPs tested and passed. Drillers log was not filled out. Depth of drilling was @ 1500'. I spoke with the mudlogger, toolpusher, driller, and company man on location, and explained what is required in the drillers log. The Operator immediately corrected the violation. No outstanding violations exist. |
1947546 | Primary Facility | 2011-01-05 | Routine/Partial Inspection | Violation(s) Noted | SW-defective cement job, 78.86(a) & 78.81(a)(2)&(3), 0.0 psi at 9 5/8 annulus & 0.4 psi at 5 1/2 annulus, 0.5% gas peaked at 9 5/8 annulus & 90% gas peaked at 5 1/2 annulus, 10 day response requested. |
1956783 | Primary Facility | 2011-03-05 | Routine/Complete Inspection | No Violations Noted | |
1980748 | Primary Facility | 2011-06-13 | Follow-up Inspection | Violation(s) Noted | |
2007727 | Primary Facility | 2011-09-02 | Routine/Complete Inspection | No Violations Noted | |
2028185 | Primary Facility | 2011-12-08 | Routine/Complete Inspection | No Violations Noted | Well is online. Vents are open - vented to Brine Tank. Approx. 2 - 3' water in cellar. No bubbling in cellar. Gauge on well reading @ 3400 psi. Inspection completed as part of an ongoing gas migration investigation. |
2035721 | Primary Facility | 2011-12-05 | Incident- Response to Accident or Event | Violation(s) Noted | |
2139940 | Primary Facility | 2013-02-14 | Follow-up Inspection | No Violations Noted | On site to collect pressure readings from annuli of well. DEP reps on site = Steve Watson, Eric Rooney, and Gene Rickard. DEP met with John Smelko of Cabot. Selman reps on site to assist with collection of pressure data. Cabot shut in annuli at @ 9am this morning. Cabot installed a digital gauge on the 16" x 9 5/8" annulus. Pressure was 0 psi. Gauge was removed and open vent flow was screened using a Model 60 gas meter. Model 60 reading = 0% cobustible gas. Gauge was then installed on 9 5/8" x 5 1/2" annulus. Pressure = 1 psi. Model 60 reading = 100 % combustible gas. No samples were collected. After completion of testing, Cabot re-conected vent lines and locked vents open. |
2481924 | Primary Facility | 2016-04-27 | Routine/Partial Inspection | No Violations Noted | The Department was on site at the Greenwood, R. Pad 1 to conduct a Routine Partial Inspection. The E&S Inspection Log indicated that Mike Brilla (TEC) conducted a Post Rain Event Inspection on 4/27/16. It appears as though the landowner has made a road to the left of the access road gate to circumvent said gate. Also, it seems as if the landowner has been working areas on the well site. There is a large area within the well pad surface that looks like wood chips have been strewn across it and sections of plastic packaging are intermixed.
The perimeter ditch does not appear to meet temporary stabilization requirements. The Department requests that the operator investigate the area and deploy a method of erosion control that is consistent with your plan. The production tanks were stained during the inspection. One of the tanks has more staining than the other. The Department requests that the operator inspect the tanks to find the origin of the staining. |
2528907 | Primary Facility | 2016-10-17 | Follow-up Inspection | No Violations Noted | |
2642428 | Primary Facility | 2017-10-02 | Site Restoration | No Violations Noted | I inspected the site for notice of termination (NOT) on October 2, 2017. The site was surrounded by active agriculture (field corn). The access road leading in was in good shape with no rutting and the site was well vegetated on the cut and fill slopes. The pad surface was solid and stable as well. There were no erosional issues noted.
I recommend APPROVAL of this NOT. There were no violations observed. |
2774791 | Primary Facility | 2018-09-11 | Routine/Complete Inspection | No Violations Noted | Arrived on location at 09:00. Weather: ~ 65 degs., light rain, slight breeze. Onsite to initiate 72 hr. pressure build up test "PBUT" on the annuli of the Greenwood 1V, 6H, 7H & 8H wells. All wells, back side of production casing annuli have been isolated and were venting to onsite poly vent tanks. The 6H, 7H & 8H wells (16"x 9 5/8") cemented annuli had open top 16" casings in cellar *. The 1V wells (9 5/8"x 7") cemented annulus was beneath water level in cellar, no bubbling was noted at time of inspection.
- Upon arrival I met with Cabot O&G Reps. Jeremy Rapp and Sully Rutledge. Prior to shutting in wells annuli, initial gas screenings and flow checks were performed at the 1V (7"x 4 1/2") and 6H, 7H & 8H (9 5/8"x 5 1/2") annuli using the Depts. Altair 5X gas meter, calibrated this morning, and Cabots' RS-484 Alicat "Whisper" flow meter. Pre-shut in screenings showed: - 1V: (7"x 4 1/2") = 100% CH4, 9.2 cf/d; (9 5/8"x 7") open casing top in cellar, No bubbling noted. - 6H: (9 5/8"x 5 1/2") = 100% CH4, 15.2 cf |
2775557 | Primary Facility | 2018-09-14 | Routine/Complete Inspection | Pending | Arrived on location at: 09:00. Weather: ~ 75 degs., Light rain, Slight breeze. Onsite to conclude the 72-hr. pressure build up test ¿PBUT¿ being performed on the Greenwood 1V, 6H, 7H & 8H wells, back side of production casing annuli and the 1V¿s (9 5/8¿x 7¿) cemented annulus.
- Upon arrival I met with Cabot O&G Rep. Sully Rutledge and Selman and Associates Reps. Kaydee Oliver and Russell Mohlt. There was also a GDS Vac Truck and Operator onsite to add or remove water to cellar areas as needed. The ending PBUT pressures were checked by Cabot Rep. using a digital Crystal pressure gauge. Ending pressures are listed below: - 1V: (7"x 4 ½¿) = 21 psi., Gas sample taken = 100% CH4; (9 5/8"x 7") = 0.0 psi., No sample taken. Cellar was initially full of water w/ no bubbling noted. Cellar was then emptied confirming (9 5/8"x 7") vent line connection to enclosed casing top. - 6H: (9 5/8¿ x 5 ½¿) = 12.0 psi. Gas sample taken = 100% CH4; (16"x 9 5/8") = 0.0 psi. (Open casing top in cellar). Cellar was initially full of w |
2804931 | Primary Facility | 2018-11-15 | Follow-up Inspection | Pending | Arrived on location at 11:00. Weather: Overcast, ~ 32 degs., Snow forecast for this afternoon. Onsite to perform initial gas flow checks at the 8H wells annuli, prior to starting the follow-up 72 hr PBUT on this well. At conclusion of the initial PBUT on 9/14/18, bubbling gas was noted to inside of the open top (16"x 9 5/8") annulus. Since the last PBUT, Cabot has capped off and contained this annulus in preparation for this follow-up PBUT. (* See Pic #1.)
Upon arrival I met with Cabot O&G Rep. Jeremy Rapp. Also present were DEP Reps. Eric Rooney, Geologist and Casey Baldwin, WQS. Initial gas screenings and flow checks were performed using the Depts. Altair 5X gas meter, calibrated this morning, and Cabots' RS-484 Alicat "Whisper" flow meter. Pre-shut in screenings showed: - 8H: (16"x 9 5/8") = 0% CH4, 0.0 cf/d; (9 5/8"x 5 1/2"") = 100% CH4, 12.8 cf/d. * Possible concern that the existing 2" (16"x 9 5/8") annular vent may be blocked by cement or debris since previous bubbling was noted in this annulus at c |
2805195 | Primary Facility | 2018-11-19 | Follow-up Inspection | Pending | Arrived on location at 09:00. Weather: Overcast, ~ 32 degs., Recent snowfall ~ 10". Onsite for conclusion of the follow-up 72 hr PBUT on the 8H wells annuli. At conclusion of the initial PBUT on 9/14/18, bubbling gas was noted to inside of the open top (16"x 9 5/8") annulus. Since the last PBUT, Cabot has capped off and contained this annulus in preparation for this follow-up PBUT. (* See Pic #1.)
Upon arrival I met with Cabot O&G Rep. Jeremy Rapp. Also present was DEP Rep. Eric Rooney, Geologist and Selman & Assoc. Rep. Tyler Thomas. The ending PBUT pressures were checked by Cabot Rep. using a digital Crystal pressure gauge. Ending gas checks were performed using the Dept's Altair 5X gas meter, calibrated on 11/15/18. Ending pressures and gas screening results are listed below: - 8H: (16"x 9 5/8")* = -3.0 psi. (vac.), 15% LEL, 0% CH4. Gas sample collected, bag gas check showed <5% LEL, 0% CH4. Results too low to send for analysis. (9 5/8"x 5 1/2")** = 17.5 psi., 100% CH4. Sample collected at 09:10.
|
Inspection ID | Violation ID | Violation Date | Date Resolved | Violation Code | Violation Type | Violation Comments |
---|---|---|---|---|---|---|
1886580 | 587792 | 05/13/2010 | 2010-05-13 | 78.122 - Drillers Log not on site | Administrative | drillers log not filled out and kept up to date |
1947546 | 604118 | 01/05/2011 | 2011-01-05 | 78.86* - Failure to report defective, insufficient, or improperly cemented casing w/in 24 hrs or submit plan to correct w/in 30 days | Administrative | 0.0 psi at 9 5/8 annulus & 0.4 psi at 5 1/2 annulus, 0.5% gas peaked at 9 5/8 annulus & 90% gas peaked at 5 1/2 annulus |
1947546 | 604119 | 01/05/2011 | 2011-01-05 | 207B - Failure to case and cement to prevent migrations into fresh groundwater | Environmental Health & Safety | 78.81(a)(2)&(3) - 0.0 psi at 9 5/8 annulus & 0.4 psi at 5 1/2 annulus, 0.5% gas peaked at 9 5/8 annulus & 90% gas peaked at 5 1/2 annulus |
1980748 | 613571 | 06/13/2011 | 2011-06-13 | 78.65(1)* - Rat hole not filled | Environmental Health & Safety | rathole cleaned and filled in |
1980748 | 613572 | 06/13/2011 | 2011-06-13 | 78.56(1) - Pit and tanks not constructed with sufficient capacity to contain pollutional substances. | Administrative | rathole cleaned and filled in |
1980748 | 613573 | 06/13/2011 | 2011-06-13 | 402CSL B - Failure to meet requirements of permit, rules and regulations, or order of DEP. | Environmental Health & Safety | rathole cleaned and filled in |
1980748 | 613574 | 06/13/2011 | 2011-06-13 | SWMA301 - Failure to properly store, transport, process or dispose of a residual waste. | Environmental Health & Safety | rathole cleaned and filled in |
2035721 | 629834 | 12/05/2011 | 2011-12-05 | 78.54* - Failure to properly control or dispose of industrial or residual waste to prevent pollution of the waters of the Commonwealth. | Environmental Health & Safety | |
2035721 | 629835 | 12/05/2011 | 2011-12-05 | 691.1 - Clean Streams Law-General. Used only when a specific CLS code cannot be used | Administrative | 402- potential for pollutional substances to enter the waters of the commonwealth |
2035721 | 629836 | 12/05/2011 | 2011-12-05 | SWMA301 - Failure to properly store, transport, process or dispose of a residual waste. | Environmental Health & Safety | 401- management of hazardous waste |
Violation ID | Penalty ID | Penalty Code | Penalty Status | Penalty Date | Enforcement Date | Penalty Amount | Amount Collected |
---|---|---|---|---|---|---|---|
604118 | 267424 | NOV - Notice of Violation | |||||
604119 | 267424 | NOV - Notice of Violation | |||||
613571 | 272562 | NOV - Notice of Violation | |||||
613572 | 272562 | NOV - Notice of Violation | |||||
613573 | 272562 | NOV - Notice of Violation | |||||
613574 | 272562 | NOV - Notice of Violation | |||||
629834 | 279932 | NOV - Notice of Violation | |||||
629835 | 279932 | NOV - Notice of Violation | |||||
629836 | 279932 | NOV - Notice of Violation |
For data sources see[8]