If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-115-20226 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.744511,"lon":-75.879614,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Susquehanna | |
Municipality: Dimock Township | |
Operator Name: CABOT OIL & GAS CORP | |
Well Pad ID: 147756 | |
Farm/Lease Name: BAKER 3 | |
License Status: | |
Spud Date: | |
Permit Date: 2009-11-12 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: No | |
Latitude: 41.744511 | |
Longitude: -75.879614 |
Date | Event |
---|---|
2009-11-12 | New Permit Application |
2009-12-11 | Performed Spud Operation |
2010-04-09 | Drilling Completion |
2010-10-27 | DEVIATED |
2012-10-05 | Perforation |
2012-10-11 | Performed Stimulation |
For data sources see[4]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2012-10-10 | 2012-10-10 | 7,051 | 6,932,352 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | Hydrochloric Acid 10.1-15 | Baker Hughes | Acidizing | Water | 7732-18-5 | 85.00 | 0.49 | |
Hydrochloric acid | 7647-01-0 | 15.00 | 0.08 | |||||
CI-14 | Baker Hughes | Corrosion Inhibitor | Propargyl alcohol | 107-19-7 | 5.00 | 0.00004000 | ||
Fatty Acids | 10.00 | 0.00009000 | ||||||
Olefin | 5.00 | 0.00004000 | ||||||
Polyoxyalkylenes | 30.00 | 0.00026000 | ||||||
Alpha 1427 | Baker Hughes | Biocide | Quaternary ammonium compounds, benzyl-C12-16-alkyldimethyl, chlorides |
68424-85-1 | 5.00 | 0.00114000 | ||
Ethanol | 64-17-5 | 5.00 | 0.00114000 | |||||
Didecyl dimethyl ammonium chloride | 7173-51-5 | 10.00 | 0.00228000 | |||||
Glutaraldehyde | 111-30-8 | 30.00 | 0.00683000 | |||||
Scaletrol 720 | Baker Hughes | Scale Inhibitor | Calcium chloride | 10043-52-4 | 5.00 | 0.00078000 | ||
Ethylene glycol | 107-21-1 | 30.00 | 0.00470000 | |||||
Ferrotrol 300L | Baker Hughes | Iron Control | Citric acid | 77-92-9 | 60.00 | 0.00077000 | ||
Sand, White, 100 mesh | Baker Hughes | Proppant | Quartz | 14808-60-7 | 100.00 | 0.61 | ||
FRW-18 | Baker Hughes | Friction Reducer | Distillates, petroleum, hydrotreated light | 64742-47-8 | 30.00 | 0.01 | ||
Clay Master-5C | Baker Hughes | Clay Control | 1,2-Ethanediaminium, N, N'-bis[2-[bis(2-hydroxyethyl)methylammonio]ethyl]-N,N'bis(2-hydroxyethyl)-N,N'-dimethyl-,tetrachlorid e |
138879-94-4 | 60.00 | 0.00036000 | ||
Sand, White, 40/70 | Baker Hughes | Proppant | Quartz | 14808-60-7 | 100.00 | 10.91 | ||
Water | Operator | Carrier | Water | 7732-18-5 | 100.00 | 87.75 |
For data sources see[5]
Stimulation Date | Phase Number | Chemical Agent | Volume (gal) | Treating Pressure (psi) | Breakdown Pressure (psi) |
---|---|---|---|---|---|
2012-10-11 | 0 | 0 | 0 |
For data sources see[6]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2009 | CABOT OIL & GAS CORP | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2010 | CABOT OIL & GAS CORP | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2011 | CABOT OIL & GAS CORP | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2012 | CABOT OIL & GAS CORP | 865,033.00 | 73 | 0.00 | 0 | 0.00 | 0 |
2013 | CABOT OIL & GAS CORP | 3,714,851.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2014 | CABOT OIL & GAS CORP | 1,982,211.00 | 363 | 0.00 | 0 | 0.00 | 0 |
2015 | CABOT OIL & GAS CORP | 949,612.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2016 | CABOT OIL & GAS CORP | 1,200,830.00 | 366 | 0.00 | 0 | 0.00 | 0 |
2017 | CABOT OIL & GAS CORP | 917,482.00 | 363 | 0.00 | 0 | 0.00 | 0 |
2018 | CABOT OIL & GAS CORP | 792,123.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2019 | CABOT OIL & GAS CORP | 617,520.00 | 362 | 0.00 | 0 | 0.00 | 0 |
For data sources see[7]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2010 | CABOT OIL & GAS CORP | Drilling Fluid Waste | 246.50 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR119 |
2010 | CABOT OIL & GAS CORP | Drilling Fluid Waste | 148.40 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0101508 |
2010 | CABOT OIL & GAS CORP | Drill Cuttings | 78.70 Tons | CENTRALIZED TREATMENT PLANT FOR RECYCLE | 101247 |
2010 | CABOT OIL & GAS CORP | Basic Sediment | 2.96 Bbl | LANDFILL | NY # 02S17 |
2010 | CABOT OIL & GAS CORP | Drill Cuttings | 21.10 Tons | LANDFILL | NY # 50S08 |
2010 | CABOT OIL & GAS CORP | Drill Cuttings | 121.50 Tons | CENTRALIZED TREATMENT PLANT FOR RECYCLE | 8-4630-00010/00 |
2010 | CABOT OIL & GAS CORP | Drill Cuttings | 121.50 Tons | LANDFILL | NY # 02S17 |
2010 | CABOT OIL & GAS CORP | Drill Cuttings | 1.70 Tons | LANDFILL | 100955 |
2011 | CABOT OIL & GAS CORP | Drilling Fluid Waste | 575.35 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2011 | CABOT OIL & GAS CORP | Drill Cuttings | 0.64 Tons | LANDFILL | 101534 |
2011 | CABOT OIL & GAS CORP | Fracing Fluid Waste | 1.32 Bbl | LANDFILL | 301626 |
2011 | CABOT OIL & GAS CORP | Drill Cuttings | 4.03 Tons | LANDFILL | 101247 |
2011 | CABOT OIL & GAS CORP | Drilling Fluid Waste | 9.42 Bbl | LANDFILL | 301626 |
2011 | CABOT OIL & GAS CORP | Drilling Fluid Waste | 11.67 Bbl | LANDFILL | 100955 |
2011 | CABOT OIL & GAS CORP | Drill Cuttings | 73.69 Tons | LANDFILL | THR029 |
2011 | CABOT OIL & GAS CORP | Drilling Fluid Waste | 6.87 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PAD014286009 |
2011 | CABOT OIL & GAS CORP | Drill Cuttings | 4.35 Tons | LANDFILL | 132310 |
2011 | CABOT OIL & GAS CORP | Drill Cuttings | 0.95 Tons | LANDFILL | 100081 |
2011 | CABOT OIL & GAS CORP | Drilling Fluid Waste | 5.04 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | |
2012 | CABOT OIL & GAS CORP | Produced Fluid | 1,100.22 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2012 | CABOT OIL & GAS CORP | Basic Sediment | 8.16 Bbl | LANDFILL | THR029 |
2012 | CABOT OIL & GAS CORP | Fracing Fluid Waste | 2,335.74 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2012 | CABOT OIL & GAS CORP | Produced Fluid | 85.32 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NE001 |
2012 | CABOT OIL & GAS CORP | Fracturing Fluid Waste | 1.55 Tons | LANDFILL | THR029 |
2012 | CABOT OIL & GAS CORP | Fracing Fluid Waste | 1,588.43 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NE001 |
2013 | CABOT OIL & GAS CORP | Produced Fluid | 700.67 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NE002 |
2013 | CABOT OIL & GAS CORP | Produced Fluid | 517.19 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE002 |
2014 | CABOT OIL & GAS CORP | Produced Fluid | 705.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE002 |
2015 | CABOT OIL & GAS CORP | Produced Fluid | 257.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE002 |
2015 | CABOT OIL & GAS CORP | Produced Fluid | 3.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE001 |
2016 | CABOT OIL & GAS CORP | Produced Fluid | 173.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE002 |
2016 | CABOT OIL & GAS CORP | Produced Fluid | 185.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE002 |
2017 | CABOT OIL & GAS CORP | Produced Fluid | 96.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC018 |
2017 | CABOT OIL & GAS CORP | Produced Fluid | 187.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE002 |
2018 | CABOT OIL & GAS CORP | Produced Fluid | 186.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE002 |
2018 | CABOT OIL & GAS CORP | Produced Fluid | 75.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC018 |
2019 | CABOT OIL & GAS CORP | Produced Fluid | 216.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE002 |
For data sources see[8]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
1852135 | Primary Facility | 2009-12-23 | Drilling/Alteration | No Violations Noted | Arrived on site at approximately 9:00am. I met with Company Man on site Jay Theriot. At the time of inspection, operator was drilling a 12-1/4" hole on air to a depth of 1500' and then will set 9-5/8"surface casing. The Company Man indicated that cementing of the surface casing would likely occur later on this day. The drillers log was on site and up to date. The area surrounding the substructure was lined with plastic and bermed. E/S controls were in place. The reserve pit had adequate freeboard and the liner appeared to be in good condition. |
1853145 | Primary Facility | 2009-12-31 | Follow-up Inspection | No Violations Noted | It was reported that 30 ¿ 40 gallons of diesel fuel spilled onto the plastic liner located directly underneath the tank. Mr. Rogier stated that all of the diesel fuel was contained and none had reached the ground. At the time of inspection, there was no visible evidence of diesel spilled beyond the secondary containment. The cause of the spill was human error. A valve that was supposed to be closed during filling was left open, and subsequently, too much fuel was pumped into the tank. The spilled diesel fuel was cleaned up with absorbent rags and squeegees and was placed in containers for disposal.Based on my inspection, the spilled diesel fuel was contained in secondary containment already in place at the site. There was no evidence of diesel fuel spilling beyond the secondary containment onto the ground. No violations were identified during this inspection. |
1871624 | Primary Facility | 2010-03-10 | Drilling/Alteration | Violation(s) Noted | |
1873022 | Primary Facility | 2010-03-24 | Follow-up Inspection | No Violations Noted | Changing out motor and bit. TOOH. Follow up on cuttings spill. Area has been cleaned up. Site ID sign has also been installed. Previous violations have been corrected. |
2107030 | Primary Facility | 2012-10-15 | Drilling/Alteration | No Violations Noted | Frac completed ,Baker hues verbally reported no problems through 20 stages , 0 lbs. pressure on the 1-v plugged well on site |
2107034 | Primary Facility | 2012-10-12 | Drilling/Alteration | No Violations Noted | Site in good shape containment sufficient preparing to frac 12/20 stage ,collected records for previous stages. |
2110041 | Primary Facility | 2012-10-16 | Drilling/Alteration | No Violations Noted | DRILLING OUT FRAC BRIDGES |
2110142 | Primary Facility | 2012-10-10 | Drilling/Alteration | No Violations Noted | On site to perform Pre-frac inspection. Met with Larry Fulmer - Completions Supt. SPCC and MSDS's on site. WEnt through Engineering Study submitted by Cabot (9/24/09) and confirmed each item was present and implemented as per study. Based on my review and inspection all items proposed by Cabot in the document are in place. mr. Fulmer indicated that they will be performing a 20 stage frac, and fraccing operations will occur 24/7. At this time no violations were observed. DEP offsite 15:30. |
2112270 | Primary Facility | 2012-10-17 | Drilling/Alteration | No Violations Noted | hooking up to gathering line location and pad in acceptable condition, water sully lines are being taken up |
2390909 | Primary Facility | 2015-07-20 | Routine/Complete Inspection | No Violations Noted | |
2487298 | Primary Facility | 2016-05-24 | Routine/Complete Inspection | No Violations Noted | At time of inspection, arrived on site at 8:50 a.m., the cellar was about three quarters full of water with no bubbling noticed, the (9x5) vent pipe was open and venting to a tank, there was 590psi on the production casing. I took a walk around the location and everything looked OK.
I left the site at 9:10 a.m. |
2641294 | Primary Facility | 2017-09-28 | Site Restoration | No Violations Noted | I inspected the Baker pad on September 28, 2017 for Notice of Termination (NOT). The site's access road was smooth and solid, with a cornfield bordering the one side. The site itself was well vegetated and nicely maintained, mowed neatly and compact in size. The vegetation was all healthy and exceeded the 70% perennial vegetative threshold. The pad surface was smooth and not rutted and there were no erosional issues present at the time of inspection.
I recommend APPROVAL of this NOT. There were no violations noted |
2672705 | Primary Facility | 2017-12-19 | Administrative/File Review | No Violations Noted | I approved a restoration report on December 19, 2017 for this well site. |
Inspection ID | Violation ID | Violation Date | Date Resolved | Violation Code | Violation Type | Violation Comments |
---|---|---|---|---|---|---|
1871624 | 583682 | 03/10/2010 | 2010-03-10 | 201G - Failure to post permit number, operator name, address, telephone number in a conspicuous manner at the site during drilling | Administrative | permit posted and cuttings cleaned up |
1871624 | 583683 | 03/10/2010 | 2010-03-10 | 601.101 - O&G Act 223-General. Used only when a specific O&G Act code cannot be used | Administrative | cuttings not contained within pit. overspray into adjacent wooded area |