X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-115-20151

Well Details

Well ID: 37-115-20151
Loading map...
Country: United States
State: Pennsylvania
County: Susquehanna
Municipality: Clifford Township
Operator Name: EXCO RESOURCES PA INC
Well Pad ID: 145873
Farm/Lease Name: LOPATOFSKY 1
License Status:
Spud Date:
Permit Date: 2009-05-07
Well Type: GAS
Unconventional Well: Y
Configuration: Vertical Well
Conservation: No
Latitude: 41.713093
Longitude: -75.590695

For data sources see[1][2][3]

Well History

Date Event
2009-05-07 New Permit Application
2009-07-15 Performed Spud Operation
2009-08-13 Drilling Completion
2009-11-30 NEWLY DRILLED

For data sources see[4]


Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2009 EXCO RESOURCES PA INC 0.00 0 0.00 0 0.00 0
2010 EXCO RESOURCES PA INC 0.00 0 0.00 0 0.00 0
2011 EXCO RESOURCES PA INC 0.00 0 0.00 0 0.00 0

For data sources see[5]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2009 EXCO RESOURCES PA INC Brine 2,238.00 Bbl Other
2010 EXCO RESOURCES PA INC Drilling Fluid Waste 576.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0027057
2010 EXCO RESOURCES PA INC Drilling Fluid Waste 543.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0008451
2010 EXCO RESOURCES PA INC Fracing Fluid Waste 8,473.20 Bbl REUSE OTHER THAN ROAD SPREADING

For data sources see[6]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1813853 Primary Facility 2009-07-01 Routine/Complete Inspection No Violations Noted
1813855 Primary Facility 2009-07-15 Routine/Complete Inspection No Violations Noted
1817523 Primary Facility 2009-07-30 Drilling/Alteration No Violations Noted At time of inspection I met with the Company Man Chester Phillips. The drilling contractor is Union with rig UDI-46.According to Company Man, the drilling contractor was in the process of testing the BOP system the previous day, and inserted the test plug upside down into an 11¿ 5000x 8-5/8 Slip on Wellhead (SOW). As a result, the plug became stuck and could not be retrieved. The contractor had to cut off the wellhead, and at the time of inspection was in the process of installing and testing the new SOW. Once installed, the BOP test will be completed.
1820611 Primary Facility 2009-08-13 Drilling/Alteration No Violations Noted At time of inspection I met with the Company Man Mike Taylor. The drilling contractor is Union Drilling with rig UDI-46. According to Mr. Taylor, depth of drilling was at 8055¿. Mr. Taylor indicated that they were in the process of washing out the hole with mud due to excess shale fragments being generated. Once cleaned out, drilling will resume to a TD of 8065¿. Mr. Taylor further stated that 4-1/2¿ production casing is scheduled to be set at approximately 8055¿.
1841249 Primary Facility 2009-10-02 Routine/Complete Inspection No Violations Noted At time of inspection I met with Mark Goodwin, Completion Supervisor for EXCO. Mr. Goodwin indicated they were in the process of pulling tubing out of the well in order to change out the tools with a ¿jet pack¿. The jet pack will be used to remove the excessive water in the hole and hopefully increase the gas flow. The well was flowing back at a rate of 5 to 6 bbls/hr during inspection. All flowback water was being contained in frac tanks.
1912359 Primary Facility 2010-09-02 Plugging(Includes Plugged/Mined Through) No Violations Noted Service rig on location. Well is planned to be plugged. NOI to plug well has been recieved.

For data sources see[7]