37-115-20091

Well Details

Well ID: 37-115-20091
Loading map...
Country: United States
State: Pennsylvania
County: Susquehanna
Municipality: Dimock Township
Operator Name: CABOT OIL & GAS CORP
Well Pad ID: 148408
Farm/Lease Name: GESFORD 4R
License Status:
Spud Date:
Permit Date: 2009-03-12
Well Type: GAS
Unconventional Well: Y
Configuration: Vertical Well
Conservation: No
Latitude: 41.733258
Longitude: -75.886172

For data sources see[1][2][3]

Well History

Date Event
2009-03-12 New Permit Application
2009-04-25 Performed Spud Operation
2009-06-09 Drilling Completion
2009-09-16 NEWLY DRILLED
2010-03-23 Perforation
2012-11-10 Performed Stimulation

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2012-11-09 2012-11-09 7,111 706,314

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Super TSC LT Paraffin & Scale Additive Proprietary 50.00 0.01
Proprietary 15.00 0.00331500
Water 7732-18-5 60.00 0.01
Water Carrier/Base Fluid 100.00 86.94
WFR-3B Friction Reducer Poly(oxy-1,2-ethanediyl), .alpha.,.alpha.'-[[(9Z)-9-octadecenylimino]di-2,1-ethanediyl]bis[.omega.-hydroxy
-
26635-93-8 5.00 0.00532500
Ethoxylated C12-16 alcohols 68551-12-2 15.00 0.01
Distillates, petroleum, hydrotreated light 64742-47-8 50.00 0.05
Microparticle 1.00 0.00106500
1,2-Propylene glycol 57-55-6 40.00 0.04
1,2-Propylene glycol 57-55-6 15.00 0.01
Water 7732-18-5 40.00 0.04
PA Specific 40/70 mesh Sand Sand - Bulk - Pennsylvania Ferric oxide 1309-37-1 0.10 0.01
Alumina 1344-28-1 1.10 0.12
Quartz 14808-60-7 99.90 11.54
Titanium dioxide 13463-67-7 0.10 0.01
PA Specific 100 mesh Sand Sand - Bulk - Pennsylvania Titanium dioxide 13463-67-7 0.10 0.00051800
Alumina 1344-28-1 1.10 0.00569800
Ferric oxide 1309-37-1 0.10 0.00051800
Quartz 14808-60-7 99.90 0.51
Iron Acid 10M (12.6-18.0) Acid Blend Hydrochloric acid 7647-01-0 15.80 0.09
Proprietary 1.20 0.00710900
Water 7732-18-5 84.10 0.49
Acid Inhibitor 2 (AI-2) Acid Corrosion Inhibitor Glycol Ethers 20.00 0.00019900
Poly(oxy-1,2-ethanediyl), alpha-(nonylphenyl)-omega-hydroxy-

,
branched

68412-54-4 13.00 0.00012900
Water 7732-18-5 40.00 0.00039800
Tar bases, quinoline derivatives,
benzyl chloride-quaternized
72480-70-7 10.00 0.00010000
Isopropanol 67-63-0 15.00 0.00014900
Propargyl alcohol 107-19-7 20.00 0.00019900
KR-153SL Biocide Water 7732-18-5 80.00 0.02
2,2-Dibromo-3-nitrilopropionamide 10222-01-2 20.00 0.00522300

For data sources see[5]

Stimulation Data

Stimulation Date Phase Number Chemical Agent Volume (gal) Treating Pressure (psi) Breakdown Pressure (psi)
2012-11-10 0 0 0

For data sources see[6]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2009 CABOT OIL & GAS CORP 0.00 0 0.00 0 0.00 0
2010 CABOT OIL & GAS CORP 0.00 0 0.00 0 0.00 0
2011 CABOT OIL & GAS CORP 0.00 0 0.00 0 0.00 0
2012 CABOT OIL & GAS CORP 16,018.51 28 0.00 0 0.00 0
2013 CABOT OIL & GAS CORP 111,264.37 365 0.00 0 0.00 0
2014 CABOT OIL & GAS CORP 63,138.32 347 0.00 0 0.00 0
2015 CABOT OIL & GAS CORP 40,713.55 365 0.00 0 0.00 0
2016 CABOT OIL & GAS CORP 42,569.70 366 0.00 0 0.00 0
2017 CABOT OIL & GAS CORP 31,656.99 363 0.00 0 0.00 0
2018 CABOT OIL & GAS CORP 29,057.00 365 0.00 0 0.00 0
2019 CABOT OIL & GAS CORP 24,864.00 362 0.00 0 0.00 0

For data sources see[7]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2009 CABOT OIL & GAS CORP Drilling 1,500.00 Bbl Brine or Industrial Waste Treatment Plt PA0027057
2009 CABOT OIL & GAS CORP Drilling 550.00 Bbl Municipal Sewage Treatment Plant PA0026034
2009 CABOT OIL & GAS CORP Drilling 122.00 Bbl Brine or Industrial Waste Treatment Plt PAR9000009
2010 CABOT OIL & GAS CORP Basic Sediment 1.85 Bbl LANDFILL 101534
2010 CABOT OIL & GAS CORP Drill Cuttings 48.80 Tons CENTRALIZED TREATMENT PLANT FOR RECYCLE 101247
2010 CABOT OIL & GAS CORP Drilling Fluid Waste 161.10 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR119
2010 CABOT OIL & GAS CORP Drill Cuttings 13.80 Tons LANDFILL NY # 50S08
2010 CABOT OIL & GAS CORP Drill Cuttings 79.40 Tons LANDFILL NY # 02S17
2010 CABOT OIL & GAS CORP Drilling Fluid Waste 97.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0101508
2010 CABOT OIL & GAS CORP Drill Cuttings 1.00 Tons LANDFILL 100955
2010 CABOT OIL & GAS CORP Drill Cuttings 79.40 Tons CENTRALIZED TREATMENT PLANT FOR RECYCLE 8-4630-00010/00
2012 CABOT OIL & GAS CORP Basic Sediment 3.99 Bbl LANDFILL THR029
2012 CABOT OIL & GAS CORP Fracing Fluid Waste 840.58 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NE001
2012 CABOT OIL & GAS CORP Produced Fluid 507.29 Bbl REUSE OTHER THAN ROAD SPREADING
2012 CABOT OIL & GAS CORP Fracing Fluid Waste 840.58 Bbl REUSE OTHER THAN ROAD SPREADING
2013 CABOT OIL & GAS CORP Produced Fluid 55.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NE001
2013 CABOT OIL & GAS CORP Produced Fluid 165.86 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2013 CABOT OIL & GAS CORP Produced Fluid 10.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE001
2013 CABOT OIL & GAS CORP Produced Fluid 571.55 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NE002
2014 CABOT OIL & GAS CORP Produced Fluid 318.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2015 CABOT OIL & GAS CORP Produced Fluid 31.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2015 CABOT OIL & GAS CORP Produced Fluid 3.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE001
2016 CABOT OIL & GAS CORP Produced Fluid 4.06 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2016 CABOT OIL & GAS CORP Produced Fluid 2.91 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2017 CABOT OIL & GAS CORP Produced Fluid 2.52 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2017 CABOT OIL & GAS CORP Produced Fluid 3.56 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC018
2018 CABOT OIL & GAS CORP Produced Fluid 23.47 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2019 CABOT OIL & GAS CORP Produced Fluid 2.50 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002

For data sources see[8]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1793057 Primary Facility 2009-04-27 Drilling/Alteration Violation(s) Noted An existing road was used to access the well site. The road and drill pad are stoned with limestone. The Site ID sign and E/S Plan were present at the entrance of the access road. At the time of inspection, the driller indicated that 13 3/8" surface casing was set at 153' and cemented. Drill crew was nippling up on the 13 3/8" to start drilling 12 1/4" hole.
1796220 Primary Facility 2009-05-01 Drilling/Alteration Viol(s) Noted & Immediately Corrected On May 1, 2009 a spill of approximately 25 gallons of diesel fuel was released on Site.
1796223 Primary Facility 2009-05-05 Drilling/Alteration No Violations Noted At the time of inspection, the drillers log was properly filled out. As a result, the violation issued during the April 27, 2009 inspection has been lifted.
1799556 Primary Facility 2009-05-20 Drilling/Alteration No Violations Noted E/S Plan on site, Site ID sign on site. All E/S controls in place and appear to be working.
1799639 Primary Facility 2008-12-08 Routine/Complete Inspection No Violations Noted
1799909 Primary Facility 2009-05-01 Routine/Complete Inspection No Violations Noted
1803454 Primary Facility 2009-06-03 Drilling/Alteration No Violations Noted E/S Plan on site, Site ID sign on site. All E/S controls in place and appear to be working. The large pit had approximately 4' of freeboard during inspection. Drillers log was on site and filled out properly. According the company man, they had drilled to TD of 7120'. Upon trying to trip out of the hole, the drill pipe got stuck due to the hole collapsing in near TD. The company man indicated they eventually were able to free the pipe and trip out of the hole. At the time of inspection, the crew was circulating mud in the hole with the use of a Superior pump truck in an effort to clean out the hole prior to setting the 4-1/2" casing. I indicated to the company man to watch the freeboard in the pit they were using to circulate mud as it was getting close to freeboard limits. I also observed a skid containing several 55 gallon drums was full of rainwater. I suggested to the company man to have that pumped out to prevent a future spill.
1804787 Primary Facility 2009-06-11 Follow-up Inspection Violation(s) Noted At time of inspection, drill rig and crew were offsite. No activity on site. The freeboard in the earth pit was approximately 3 - 6" from the top of the pit. It appears that some of the drilling mud had spilled out of the end of the pit onto the pad as evident from a large puddle of mud.
1804893 Primary Facility 2009-06-12 Follow-up Inspection Outstanding Violations - Viols Req'd Arrived on Site 8:00 am to complete follow up inspection on earthpit. I had spoken with Safety and Environmental officer for GasSearch on 06.11.09 about the freeboard issue at the site. I also spoke with one of Cabot's Company Man regarding the issue. A call was made at that time by the Co. man to the trucking coordinator to arrange to have the liquid removed from the pits at the Site. Upon arrival this morning to site, it appeared that one end of the earth pit has been pumped down approximately 12", however, freeboard is still above 2' limit. The other end of earthpit has between 3 - 6" of freeboard.
1806238 Primary Facility 2009-06-18 Routine/Complete Inspection Violation(s) Noted Follow-up inspection, MO'D & SW, contents of earth pit removed and liner revealed numerous tears, reserve pit condition same as previously observed with tear in pit liner and inadequate freeboard.
1811450 Primary Facility 2009-07-10 Follow-up Inspection No Violations Noted Arrived on site to complete follow up inspection of earth pit and reserve pit issues noted on DEP NOV letter issued 6/29/09 regarding freeboard and pit liner issues. At the time of inspection, the smaller pit had been cleaned up and removed, and filled and graded back to pad level. the larger reserve pit has been reshaped with higher sidewalls extending approximately 3' above pad level. The pit has been relined with a new liner. A shallower pit has been installed adjacent the new reserve pit which will be the location for the shaker unit. This pit has also been lined with a new liner.
1833421 Primary Facility 2009-09-25 Follow-up Inspection No Violations Noted An existing road was used to access the well site. The road and drill pad are stoned with limestone. The Site ID sign and E/S Plan were present at the entrance of the access road.
1845070 Primary Facility 2009-11-10 Follow-up Inspection No Violations Noted I inspected the well head for evidence of leakage. There was no standing water present in the cellar and no visible bubbling observed. The well is currently shut in.
1845625 Primary Facility 2009-11-04 Routine/Complete Inspection No Violations Noted
1864357 Primary Facility 2010-02-17 Routine/Complete Inspection No Violations Noted Inspected well as per DEP COA issued to Operator. Operator planning to frac. Based in DEP inspection, no violations were observed.
1960363 Primary Facility 2011-03-22 Routine/Complete Inspection Violation(s) Noted
1981733 Primary Facility 2011-06-14 Follow-up Inspection No Violations Noted
2007759 Primary Facility 2011-09-02 Routine/Complete Inspection Violation(s) Noted Adequate company response submitted 11/13/2013.
2119420 Primary Facility 2012-11-21 Routine/Complete Inspection No Violations Noted well has been HF 3100# on well
2121471 Primary Facility 2012-11-08 Incident- Response to Accident or Event No Violations Noted The Department was on site in response to a self-reported release. At the time of the inspection, the Department met with two Nahbors employees who were unaware of the release. The Department requested that they contact a Cabot employee concerning the inspection. The Department then met with Rafael Rodriguez (Completions Consultant- Cabot Oil & Gas). At this time Rafael explained that on 11/7/12 at 21:30 that a low pressure suction manifold on a pump truck came apart. It was reported that 20 bbl. were released to containment. It was initially determined that the release was “slick water” or freshwater mixed with friction reducer. This was noted to have occurred during Stage 12 pad. They are currently on Stage 15 of 17.Brody Webster of Cabot Oil & Gas arrived on site.Brody stated that they used a 100 bbl. vacuum truck to remove the liquid. A swath of sand was noted alongside the truck.
2136392 Primary Facility 2013-02-05 Routine/Complete Inspection No Violations Noted On site to do routine inspection. Two wells on site (4V and 8H). Both wells in production. Annuli vented. Gauges on backside of production shows 0 psi. Well tag present. Site ID sign in place. Site has been restored. No violations observed at this time.
2139928 Primary Facility 2013-02-14 Follow-up Inspection No Violations Noted On site to collect pressure reading and isotopic gas sample from annulus of well. DEP reps on site = Steve Watson, Eric Rooney, and Gene Rickard. DEP met John Smelko of Cabot on site. Selman reps on site to assist with collecting gas readings and to split gas samples. Cabot shut in annulus on well @ 9am this morning. A digital gauge was installed on 7 5/8" x 4 1/2" annulus. Pressure indicated 0 psi. Gauge was removed and open vent flow was screened using Model 60 gas meter. Reading was 4% combustible gas. DEP and Cabot collected samples for isotopic analysis. The pressure gauge was then installed on the 9 5/8" x 7" annulus. Pressure reading was 0 psi. Model 60 reading was 1.5% combustible gas. DEP and Cabot collected samples for isotopic analysis. After competion of sampling, Cabot re-connected vent lines and locked vents open.
2344215 Primary Facility 2015-02-11 Complaint Inspection No Violations Noted The Department (Scott Kuchta-DEP WQS and I) was on site at the Gesford 4 & 8 well site in response to a complaint (2/7/15) concerning venting from the production tanks. At the time of the inspection, no venting was noted. The Department inspected the snow covered area around the tanks to check for indications of a fluid release. No evidence of released fluid was noted.
2509186 Primary Facility 2016-08-04 Complaint Inspection No Violations Noted At time of inspection, arrived on site at 12:05p.m. pertaining to a complaint called into the department about a backhoe and a dumpster being hauled onto the site and unknown activity. There was no activity on this site at time of inspection. There was no backhoe on site but there were two role off containers on the Castello J Pad 1 site. The marks on the entrance road indicated that the containers have recently been dropped off.

I left the site at 12:10p.m.

2642900 Primary Facility 2017-10-02 Site Restoration No Violations Noted I inspected the Gesford K, P4 site on October 2, 2017 to conduct a Notice of Termination (NOT) inspection.

The site was compact and well maintained. The access road was solid and stable. The pad surface was solid as well. The cut and fill slopes exceeded the 70% vegetative standard. On the east side of the pad, active agriculture was ongoing (field corn). There was no erosional issues apparent at the time of inspection.

I recommend APPROVAL of this NOT.

There were no violations noted.

2672710 Primary Facility 2017-12-19 Administrative/File Review No Violations Noted I approved a restoration report on December 19, 2017 for this well site.
2677351 Primary Facility 2017-12-20 Incident- Response to Accident or Event Viol(s) Noted & Immediately Corrected I arrived at the site in response to a reported spill of production fluid to the pad surface on 12-14-17. I was accompanied by Matt Shope, DEP O&G WQS. We met with Jordan Hoffman, lease operator of Cabot. The weather conditions were partly cloudy skies with a light breeze, occasional wind gusts, and temperatures in the mid 30's. I was first informed of the release on 12-19-17. I contacted Steve Watson, Environmental Health Specialist of Cabot Oil & Gas on 12-19-17 at 13:29 to acquire the specifics of the spill incident. He explained the following details regarding the spill. "The spill occurred at the Gesford 4 pad on State Route 3023 in Dimock. The above ground dump line froze as part of the Gesford 8H well. A flange fitting on the line separated spilling production fluid to the pad surface around 8:30 PM on 12/14/17. I reported the spill to the PADEP Emergency Response Team in NERO at 9:20 PM on 12/14/17. Soap sticks were added into the well on 12/13/17 to help lift the water in the gas since it is an old
2677768 Primary Facility 2017-12-20 Incident- Response to Accident or Event No Violations Noted I arrived at the site in response to a reported spill of production fluid to the pad surface on 12-14-17. I was accompanied by Matt Shope, DEP O&G WQS. We met with Jordan Hoffman, lease operator of Cabot. The weather conditions were partly cloudy skies with a light breeze, occasional wind gusts, and temperatures in the mid 30's. I was first informed of the release on 12-19-17. I contacted Steve Watson, Environmental Health Specialist of Cabot Oil & Gas on 12-19-17 at 13:29 to acquire the specifics of the spill incident. He explained the following details regarding the spill. "The spill occurred at the Gesford 4 pad on State Route 3023 in Dimock. The above ground dump line froze as part of the Gesford 8H well. A flange fitting on the line separated spilling production fluid to the pad surface around 8:30 PM on 12/14/17. I reported the spill to the PADEP Emergency Response Team in NERO at 9:20 PM on 12/14/17. Soap sticks were added into the well on 12/13/17 to help lift the water in the gas since it is an old

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
1793057 561525 04/27/2009 2009-04-27 78.122 - Drillers Log not on site Administrative 5/5/09 inspection, ID 1796223, found the drillers log was properly filled out. As a result, the violation issued during the 4/27/09 inspection has been lifted. MBC 5/20/09
1796220 564479 05/01/2009 2009-05-01 601.101 - O&G Act 223-General. Used only when a specific O&G Act code cannot be used Administrative 78.54
1804787 564743 06/11/2009 2009-06-11 78.56FRBRD - Failure to maintain 2' freeboard in an impoundment Administrative See Insp ID 1811450 done 7/10/09, all past viols corrected. MBC 8/12/09
1804787 565124 06/11/2009 2009-06-11 78.56LINER - Improperly lined pit Administrative See Insp ID 1811450 done 7/10/09, all past viols corrected. MBC 8/12/09
1804893 564749 06/12/2009 2009-06-12 78.56FRBRD - Failure to maintain 2' freeboard in an impoundment Administrative See Insp ID 1811450 done 7/10/09, all past viols corrected. MBC 8/12/09
1806238 565115 06/18/2009 2009-06-18 78.56FRBRD - Failure to maintain 2' freeboard in an impoundment Administrative See Insp ID 1811450 done 7/10/09, all past viols corrected. MBC 8/12/09
1960363 607484 03/22/2011 2011-03-22 102.4 - Failure to minimize accelerated erosion, implement E&S plan, maintain E&S controls. Failure to stabilize site until total site restoration under OGA Sec 206(c)(d) Environmental Health & Safety
1960363 607485 03/22/2011 2011-03-22 78.53* - Failure to implement and maintain BMPs in accordance with Chapter 102. Administrative
2007759 621405 09/02/2011 2011-09-02 SWMA301 - Failure to properly store, transport, process or dispose of a residual waste. Environmental Health & Safety Adequate company response submitted 11/13/2013.
2007759 621406 09/02/2011 2011-09-02 691.1 - Clean Streams Law-General. Used only when a specific CLS code cannot be used Administrative Adequate company response submitted 11/13/2013.
2007759 621407 09/02/2011 2011-09-02 78.57 - Failure to post pit approval number Administrative Adequate company response submitted 11/13/2013.
2677351 805073 2017-12-20 2017-12-20 CSL 402(b) Environmental Health & Safety The violation is cited due to the 12-14-17 production fluid spill impacting the pad surface.
2677351 805074 2017-12-20 2017-12-20 78A57(A)___ Environmental Health & Safety The violation is cited due to the 12-14-17 production fluid spill impacting the pad surface.
2677351 805075 2017-12-20 2017-12-20 SWMA 301 Environmental Health & Safety The violation is cited due to the 12-14-17 production fluid spill impacting the pad surface.

Penalties Applied

Violation ID Penalty ID Penalty Code Penalty Status Penalty Date Enforcement Date Penalty Amount Amount Collected
561525 246812 NOV - Notice of Violation Comply/Closed 2009-05-05
564743 247540 NOV - Notice of Violation Comply/Closed 2009-07-10
565124 247540 NOV - Notice of Violation Comply/Closed 2009-07-10
564749 247540 NOV - Notice of Violation Comply/Closed 2009-07-10
565115 247540 NOV - Notice of Violation Comply/Closed 2009-07-10

For data sources see[9]

References