X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-115-20034

Well Details

Well ID: 37-115-20034
Loading map...
Country: United States
State: Pennsylvania
County: Susquehanna
Municipality: Dimock Township
Operator Name: CABOT OIL & GAS CORP
Well Pad ID: 148289
Farm/Lease Name: ELY 4H
License Status:
Spud Date:
Permit Date: 2008-03-14
Well Type: GAS
Unconventional Well: Y
Configuration: Vertical Well
Conservation: Yes
Latitude: 41.724333
Longitude: -75.871429

For data sources see[1][2][3]

Well History

Date Event
2008-03-14 New Permit Application
2008-03-27 Performed Spud Operation
2008-04-14 Drilling Completion
2008-11-06 Perforation
2008-11-06 Performed Stimulation
2009-02-27 NEWLY DRILLED

For data sources see[4]

Stimulation Data

Stimulation Date Phase Number Chemical Agent Volume (gal) Treating Pressure (psi) Breakdown Pressure (psi)
2008-11-06 0 0 0

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2009 CABOT OIL & GAS CORP 446068.90 365 0.00 0 0.00 0
2010 CABOT OIL & GAS CORP 219,765.00 343 0.00 0 0.00 0
2011 CABOT OIL & GAS CORP 81,019.89 328 0.00 0 0.00 0
2012 CABOT OIL & GAS CORP 65,098.28 363 0.00 0 0.00 0
2013 CABOT OIL & GAS CORP 74,816.94 363 0.00 0 0.00 0
2014 CABOT OIL & GAS CORP 74,557.78 276 0.00 0 0.00 0
2015 CABOT OIL & GAS CORP 73,670.66 351 0.00 0 0.00 0
2016 CABOT OIL & GAS CORP 60,688.18 365 0.00 0 0.00 0
2017 CABOT OIL & GAS CORP 61,821.39 362 0.00 0 0.00 0
2018 CABOT OIL & GAS CORP 51,025.00 310 0.00 0 0.00 0
2019 CABOT OIL & GAS CORP 52,552.00 365 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2009 CABOT OIL & GAS CORP Brine 1,144.00 Bbl Municipal Sewage Treatment Plant PA0026034
2010 CABOT OIL & GAS CORP Drilling Fluid Waste 164.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR119
2010 CABOT OIL & GAS CORP Basic Sediment 1.85 Bbl LANDFILL 101534
2010 CABOT OIL & GAS CORP Drilling Fluid Waste 98.70 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0101508
2010 CABOT OIL & GAS CORP Drill Cuttings 49.60 Tons CENTRALIZED TREATMENT PLANT FOR RECYCLE 101247
2010 CABOT OIL & GAS CORP Produced Fluid 46.95 Bbl REUSE OTHER THAN ROAD SPREADING
2010 CABOT OIL & GAS CORP Drill Cuttings 14.00 Tons LANDFILL NY # 50S08
2010 CABOT OIL & GAS CORP Drill Cuttings 80.80 Tons CENTRALIZED TREATMENT PLANT FOR RECYCLE 8-4630-00010/00
2010 CABOT OIL & GAS CORP Drill Cuttings 80.80 Tons LANDFILL NY # 02S17
2010 CABOT OIL & GAS CORP Drill Cuttings 1.10 Tons LANDFILL 100955
2011 CABOT OIL & GAS CORP Basic Sediment 0.15 Bbl LANDFILL 101534
2011 CABOT OIL & GAS CORP Produced Fluid 28.52 Bbl REUSE OTHER THAN ROAD SPREADING
2012 CABOT OIL & GAS CORP Basic Sediment 0.47 Bbl LANDFILL 100081
2012 CABOT OIL & GAS CORP Produced Fluid 40.00 Bbl REUSE OTHER THAN ROAD SPREADING
2014 CABOT OIL & GAS CORP Produced Fluid 23.50 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2014 CABOT OIL & GAS CORP Produced Fluid 27.50 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE001
2015 CABOT OIL & GAS CORP Produced Fluid 38.93 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2015 CABOT OIL & GAS CORP Produced Fluid 3.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE001
2016 CABOT OIL & GAS CORP Produced Fluid 48.54 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2017 CABOT OIL & GAS CORP Produced Fluid 47.47 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2018 CABOT OIL & GAS CORP Produced Fluid 8.24 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2019 CABOT OIL & GAS CORP Produced Fluid 28.09 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1716897 Primary Facility 2008-06-26 Routine/Complete Inspection No Violations Noted
1722988 Primary Facility 2008-07-17 Routine/Complete Inspection No Violations Noted
1726694 Primary Facility 2008-08-06 Routine/Complete Inspection No Violations Noted
1753550 Primary Facility 2008-11-24 Routine/Complete Inspection No Violations Noted
1761073 Primary Facility 2008-01-06 Routine/Complete Inspection No Violations Noted
1761548 Primary Facility 2009-01-06 Routine/Complete Inspection No Violations Noted
1764323 Primary Facility 2009-01-20 Routine/Complete Inspection No Violations Noted
1764325 Primary Facility 2009-01-21 Routine/Complete Inspection No Violations Noted
1765452 Primary Facility 2008-04-08 Drilling/Alteration Outstanding Violations - No Viols Req'd
1765460 Primary Facility 2008-04-15 Drilling/Alteration No Violations Noted
1765469 Primary Facility 2009-01-26 Routine/Complete Inspection No Violations Noted
1765471 Primary Facility 2008-09-03 Routine/Complete Inspection Violation(s) Noted
1765472 Primary Facility 2009-01-27 Routine/Complete Inspection No Violations Noted
1765474 Primary Facility 2008-06-03 Routine/Complete Inspection Violation(s) Noted
1765481 Primary Facility 2008-04-07 Drilling/Alteration Violation(s) Noted
1765620 Primary Facility 2009-01-27 Routine/Complete Inspection No Violations Noted
1770594 Primary Facility 2009-02-18 Routine/Complete Inspection No Violations Noted
1774166 Primary Facility 2009-03-05 Routine/Complete Inspection No Violations Noted
1774899 Primary Facility 2009-02-18 Administrative/File Review Violation(s) Noted
1799656 Primary Facility 2008-12-09 Routine/Complete Inspection No Violations Noted
1833463 Primary Facility 2009-09-25 Follow-up Inspection No Violations Noted An existing road was used to access the well site. The road and drill pad are stoned with limestone. The Site ID sign and E/S Plan were present at the entrance of the access road.
1845079 Primary Facility 2009-11-10 Follow-up Inspection No Violations Noted I inspected the well head for evidence of leakage. There was no standing water present and no visible bubbling observed. The base of the well was filled in with P-gravel to ground level. The 7" casing is currently vented.
1876535 Primary Facility 2010-04-13 Follow-up Inspection No Violations Noted I inspected the well head for evidence of leakage. There was no standing water present. The base of the wellhead was filled in with P-gravel to ground level. Water was poured around the base of the wellhead where the top of the 9-5/8"casing was visible. No bubbling was observed. The 7" casing is currently vented. The well is online and producing. Gas readings were collected using a Model 60 gas meter. No readings were detected. There was no activity on site. The site has been restored.
2123786 Primary Facility 2012-12-12 Complaint Inspection No Violations Noted Arrived at the site at 11:00 in response to an alleged complaint of leaking brine tanks. The Department received the complaint on 12-11-12 at 10:35. I was accompanied by Briana Cunningham, DEP WQS. During the inspection the Department did not observe any evidence of leaking brine tanks or brine spills at the site. I used an an Extech, ExStik (2) pH, Conductivity, Salinty and TDS meter to field screen areas of ponded water inside of the earthen containment berm where the production fluid tanks are stored at the site. The highest conductivity reading I recorded was (114) microSiemens/cm. On average, conductivity readings were in the the range of (90-100) microSiemems/cm. The water inside the berm was noted to be mostly frozen and experienced little to no turbidity. Several times, I had to break the ice to record a reading. Departed from the site at 11:20.
2436219 Primary Facility 2015-12-22 Site Restoration No Violations Noted Inspection of the Ely K P3 Well Pad in response to a submitted Notice of Termination request for the Erosion and Sedimentation Control Permit.
2490173 Primary Facility 2016-06-01 Routine/Complete Inspection No Violations Noted At time of inspection, arrived on site at 12:20 p.m., the cellar was full of gravel with water setting on the top with no bubbling noticed, the (9x7) vent pipe was open and venting to a tank, the (7x4) vent pipe was open and venting to a tank, there was 627psi on the production casing. I took a walk around the location and everything looked OK.

I left the site at 1:15 p.m.

2629138 Primary Facility 2017-08-22 Routine/Complete Inspection No Violations Noted Arrived at location at: 09:00. There are (2) wells currently on this pad, the Ely, K 4V and 6H wells. Upon arrival I spoke with Cabot O&G Rep., Brian Pert, a Meter Tech Trainee. Brian informed that He and other Meter Techs. were in the process of retrofitting all the existing producing wells on all (3) of the Ely, K Pads (1, 2 & 3) with updated metering and Pad layouts. This work should be completed on all (3) Pads in next few weeks.
 Upon inspection of the Ely 4V and 6 H wells, both wells were set-up for automated production. Neither wells were producing at time of inspection. Both wells annuli, the (9 5/8"x 7") & (7"x 4 1/2") were open and venting to a small, shared vent tank via a common vent pipe. A gas check performed at the open top of vent tank showing 4% methane detected. A follow-up inspection will be arranged with Cabot to separate vent lines and perform individual annuli gas checks to confirm source of venting gas. 
 Both wells prod casing annuli were shut in and prod. Trees were lined up to pro
2632364 Primary Facility 2017-08-29 Routine/Complete Inspection No Violations Noted On location to perform gas checks at the Ely 4V and 6H wells annuli prior to starting a 48 Hr PBUT on these two wells. The 4V and 6H wells (9 5/8"x 7") and (7"x 4 1/2") have been separated and individually vented to onsite vent tanks. (2) Cabot Field techs and (2) Selman and Associates techs were onsite to initiate 48 hr. PBUT. At ~ 09:15 initial gas checks were performed. The Depts gas checks were performed using an Altair 5X gas meter calibrated on 8/17/17. The Depts initial gas checks showed:

- Ely 4V: (9x7)= 0% gas, Peak 10% LEL diminishing to 0% LEL; (7x4)= 100% gas, 100% LEL. - Ely 6H: (9x7)= 0% gas, Peak 20% LEL diminishing to 0% LEL; (7x4)= 0% gas, 0% LEL.

  Cabot Field techs shut both wells (9x7) and (7x4) annuli in at ~ 09:30. PBUT pressure will be recorded through test period via Total Flow Control Unit. Both wells will remain lined up for automated production throughout test period.
  We will return to conclude PBUT on 8/31/17 @ ~ 10:00.
2727098 Primary Facility 2018-05-04 Routine/Complete Inspection No Violations Noted Arrived on location at 09:30. Weather: Light rain, mild ~ 65 degs. Onsite to witness the start of 72 hr. PBUT to be performed on the Ely 6H well. Upon arrival, Both wells, the Ely 4H & 6H wells were in production. Both wells (9 5/8"x 7") & (7"x 4 1/2") annular vents were open and venting to separate poly vent tanks. Gas checks performed at both wells vent tanks showed:

- 4H: (9x7) = 0% LEL, 0% CH4; (7x4) = 4% LEL, 0% CH4 - 6H: (9x7) = 0% LEL, 0% CH4; (7x4) = 100% LEL, 100% CH4 Both wells Prod. Casing, Static and Differential pressure were being monitored by Cygnet monitoring system. Each wells pressures were collected off LED read outs by gas production units "GPU". Both wells pressures are listed below: (Prod. Casing Press. = "PCP"; Static Press. = "SP"; Differential Press. = "DP") - 4H: PCP = 484.4 psi.; SP = 491.3 psi.; DP = 69.8 psi. - 6H: PCP = 470.2 psi.; SP = 494.6 psi.; DP = 147.2 psi. Cabot O&G Reps. Jeremy Rapp and Steven Catalfamo arrived onsite at ~ 09:50. The 6Hs annuli vents were shut in at 10:

2729749 Primary Facility 2018-05-07 Routine/Complete Inspection No Violations Noted Arrived on location at 09:30. Weather: Overcast, mild ~ 55degs. Onsite to conclude the 72 hr. Pressure build-up test ¿PBUT¿ being performed on the Ely 6H well. This wells (9 5/8"x 7") & (7"x 4 1/2") were SI on 5/4/18 @ 10:00. Upon arrival, I met with Cabot O&G Reps., Jeremy Rapp and Steven Catalfamo; Selma & Assoc. Rep., Matt Went; D.E.P. Geologist, Eric Rooney; D.E.P. WQS Supervisor, Brianna Cunningham and WQS, Casey Baldwin.

- At 10:00 the ending pressures were checked with digital gauge and recorded. (9x7) = 0.0 psi.; (7x4) = 84.4 psi. Gas checks performed at each annuli showed: (9x7) = 0% LEL, 0% CH4; (7x4) = 100% LEL, 100% CH4. Gas samples were collected off the (7x4) annulus by the Dept. and Selma & Assoc. at ~ 10:00. Samples will be sent out for laboratory analysis. At conclusion of sampling, both these annuli were opened up to vent to separate poly vent tanks.

Both wells, the 4H & 6H were producing at time of insp. Prod. Casing, Static and Differential pressure were being monitored by Cygnet monitor

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
1765471 555023 09/03/2008 2008-09-03 102.4INADPLN - E&S Plan not adequate Administrative
1765474 555026 06/03/2008 2008-06-03 102.4 - Failure to minimize accelerated erosion, implement E&S plan, maintain E&S controls. Failure to stabilize site until total site restoration under OGA Sec 206(c)(d) Environmental Health & Safety
1765481 555027 04/07/2008 2008-04-07 78.56FRBRD - Failure to maintain 2' freeboard in an impoundment Administrative
1774899 557996 02/18/2009 2009-02-18 212WELLRCD - Failure to submit well record within 30 days of completion of drilling Administrative

Penalties Applied

Violation ID Penalty ID Penalty Code Penalty Status Penalty Date Enforcement Date Penalty Amount Amount Collected
555023 242227 NOV - Notice of Violation Comply/Closed 2008-11-04
555026 242228 NOV - Notice of Violation Comply/Closed 2008-06-26
555027 242229 NOV - Notice of Violation Comply/Closed 2008-04-09
557996 244244 NOV - Notice of Violation Superseded 2010-04-15
557996 252129 COA - Consent Order and Agreement Superseded 2010-04-15 $120,000.00 $120,000.00