37-113-20128

Well Details

Well ID: 37-113-20128
Loading map...
Country: United States
State: Pennsylvania
County: Sullivan
Municipality: Cherry Township
Operator Name: CHIEF OIL & GAS LLC
Well Pad ID: 149614
Farm/Lease Name: YONKIN UNIT 2H
License Status: INACTIVE
Spud Date:
Permit Date: 2011-12-01
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.545872
Longitude: -76.4269

For data sources see[1][2][3]

Well History

Date Event
2011-12-01 New Permit Application
2012-03-15 Performed Spud Operation
2014-10-24 Inactive Well Request Granted

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2013-07-01 2013-07-03 7,655 3,249,540
2 2012-06-26 2012-06-26 7,655 1,631,574

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Gyptron T-390 Champion Technologies Scale Inhibitor Methanol 67-56-1 10 0.001 0
Hydrochloric Acid 10-30% Halliburton Acid Hydrochloric Acid 7647-01-0 30 0.14 0
Bactron K-139 Champion Technologies Biocide Glutaraldehyde 111-30-8 5 0.002 0
Ethanol 64-17-5 5 0.002 0
Quaternary ammonium compounds,
benzyl-C-12-16 alkyldimethyl, chlorides
68424-85-1 10 0.004 0
Water Provided by Customer Base Fluid Fresh Water 0000-00-0 100 99.81 0
FR-66 Halliburton Friction Reducer Hydrotreated Light Petroleum Distillate 64742-47-8 30 0.03 0
BA-40L Halliburton Buffering Agent Potassium Carbonate 584-08-7 60 0.01 0
2 FRW-600 Frac Tech Services (FTS) Friction Reducer Distillates, petroleum, hydrotreated light 64742-47-8 0.11
Fresh Water Base Fluid
Fresh Water 100.00 73.49
Sand (Proppant) Frac Tech Services (FTS) Propping Agent Quartz 14808-60-7 99.90 25.85
Biocide - Bactron K 139 Champion Technologies Biocide Glutaraldehyde 111-30-8 0.04
Quaternary ammonium compounds,
benzyl-C12-16-alkyldimethyl, chlorides
68424-85-1
benzyl-C12-16 alkyldimethyl,chlorides
Ethanol 64-17-5
Hydrochloric Acid 15 Frac Tech Services (FTS) Acid Water 7732-18-5
Hydrochloric acid 7647-01-0 0.49
Scale Inhibitor - Gyptron T-390 Champion Technologies Scale Inhibitor
Methanol 67-56-1 0.01

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2011 CHIEF OIL & GAS LLC 0.00 0 0.00 0 0.00 0
2012 CHIEF OIL & GAS LLC 0.00 0 0.00 0 0.00 0
2013 CHIEF OIL & GAS LLC 0.00 0 0.00 0 0.00 0
2014 CHIEF OIL & GAS LLC 0.00 0 0.00 0 0.00 0
2015 CHIEF OIL & GAS LLC 1,282,474.47 245 0.00 0 0.00 0
2016 CHIEF OIL & GAS LLC 1,160,204.11 363 0.00 0 0.00 0
2017 CHIEF OIL & GAS LLC 844,061.44 290 0.00 0 0.00 0
2018 CHIEF OIL & GAS LLC 636,485.26 365 0.00 0 0.00 0
2019 CHIEF OIL & GAS LLC 415,444.19 365 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2012 CHIEF OIL & GAS LLC Drill Cuttings 1,094.36 Tons LANDFILL 100933
2012 CHIEF OIL & GAS LLC Fracing Fluid Waste 2,005.00 Bbl REUSE OTHER THAN ROAD SPREADING
2013 CHIEF OIL & GAS LLC Fracing Fluid Waste 1,179.00 Bbl REUSE OTHER THAN ROAD SPREADING
2013 CHIEF OIL & GAS LLC Fracturing Fluid Waste 37.07 Tons RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC006
2015 CHIEF OIL & GAS LLC Produced Fluid 4,118.89 Bbl REUSE OTHER THAN ROAD SPREADING
2016 CHIEF OIL & GAS LLC Produced Fluid 2,790.11 Bbl REUSE OTHER THAN ROAD SPREADING
2017 CHIEF OIL & GAS LLC Produced Fluid 2,284.81 Bbl REUSE (AT WELL PAD)
2017 CHIEF OIL & GAS LLC Produced Fluid 175.14 Bbl REUSE OTHER THAN ROAD SPREADING
2018 CHIEF OIL & GAS LLC Produced Fluid 462.37 Bbl REUSE (AT WELL PAD)
2019 CHIEF OIL & GAS LLC Produced Fluid 1,012.86 Bbl REUSE (AT WELL PAD)

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2055095 Primary Facility 2012-03-28 Drilling/Alteration No Violations Noted
2057655 Primary Facility 2012-04-05 Drilling/Alteration No Violations Noted
2062476 Primary Facility 2012-04-25 Routine/Complete Inspection No Violations Noted
2063551 Primary Facility 2012-04-19 Follow-up Inspection Violation(s) Noted Inspection in response to spill report, not routine partial.
2184118 Primary Facility 2013-07-16 Routine/Complete Inspection No Violations Noted
2303222 Primary Facility 2014-08-26 Routine/Complete Inspection No Violations Noted
2330286 Primary Facility 2014-12-08 Routine/Complete Inspection No Violations Noted
2462304 Primary Facility 2016-03-08 Routine/Complete Inspection No Violations Noted Site vegetated with >70% vegetative cover. No evidence of accelerated erosion or sedimentation was observed. Pad surface has been decompacted and vegetated as interim restoration. Electrical conductance of puddles on the pad was not screened due to the absence of puddles.

No violations were cited during this inspection.

2483558 Primary Facility 2016-05-13 Site Restoration No Violations Noted
2544453 Primary Facility 2016-12-13 Routine/Partial Inspection No Violations Noted Routine inspection to assess overall site conditions. Approximately 3-4 inches of snow cover is present over the entire site. No Chesapeake representatives were present.

An air-drill rig has just been removed from the site, and the containment for the drilling activities is in place. No evidence of spill such as staining or odors was observed. Due to cold weather and snow cover, direct observation of the entire well pad surface was not possible. Puddles on the pad surface were frozen, so no screening of electrical conductivity was completed.

No violations were cited during this inspection.

2559333 Primary Facility 2017-02-06 Routine/Complete Inspection No Violations Noted Routine inspection to assess site conditions during drilling operations. Mark Calicutt of Chief was the company man on site.

No evidence of releases such as odors, sheens, or staining was observed. Five barrels were observed being stored outside of containment. I mentioned these to Mr. Calicutt who stated they would be moved to containment immediately. All other chemicals, materials and equipment on site were being stored within containment.

No violations were issued during this inspection.

2564802 Primary Facility 2017-02-24 Routine/Complete Inspection No Violations Noted Inspection to assess site conditions after drilling operations. No violations cited.
2581985 Primary Facility 2017-04-12 Routine/Complete Inspection No Violations Noted Three wells drilled and one in production phase(2H). One separator within plastic containment. At least detecting from production equipment. The plastic liner and felt remain on location.
2784691 Primary Facility 2018-10-03 Routine/Complete Inspection No Violations Noted Arrived onsite for a routine site inspection. The pad has been been reduced in size and the site exceeds 70% vegetative cover.

There are 3 properly tagged Marcellus wells staged for production. There are also 3 produced water tanks and 3 GPUs onsite and in secondary containment.

At the time of inspection it was observed that a white storage container plumbed to a well head was missing a cap (Photo #4). It is recommended that this cap be replaced to prevent rainwater from entering the container and possibly causing it to overflow.

No violations noted.

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
2063551 638183 04/19/2012 2012-04-19 78.54* - Failure to properly control or dispose of industrial or residual waste to prevent pollution of the waters of the Commonwealth. Environmental Health & Safety
2063551 638184 04/19/2012 2012-04-19 402CSL - Failure to adopt pollution prevention measures required or prescribed by DEP by handling materials that create a danger of pollution. Environmental Health & Safety
2063551 638185 04/19/2012 2012-04-19 SWMA301 - Failure to properly store, transport, process or dispose of a residual waste. Environmental Health & Safety

Penalties Applied

Violation ID Penalty ID Penalty Code Penalty Status Penalty Date Enforcement Date Penalty Amount Amount Collected
638183 283275 NOV - Notice of Violation Administrative Close Out 2012-05-11
638184 283275 NOV - Notice of Violation Administrative Close Out 2012-05-11
638185 283275 NOV - Notice of Violation Administrative Close Out 2012-05-11

For data sources see[8]

References