37-113-20082

Well Details

Well ID: 37-113-20082
Loading map...
Country: United States
State: Pennsylvania
County: Sullivan
Municipality: Cherry Township
Operator Name: CHIEF OIL & GAS LLC
Well Pad ID: 146346
Farm/Lease Name: DACHEUX UNIT 1H
License Status:
Spud Date: 2012-06-05
Permit Date: 2010-12-17
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: Yes
Latitude: 41.522058
Longitude: -76.414364

For data sources see[1][2][3]

Well History

Date Event
2010-12-17 New Permit Application
2011-12-07 Permit Renewal Application
2012-06-15 Performed Spud Operation
2012-07-18 Drilling Completion
2012-10-18 DEVIATED

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2012-08-11 2012-08-11 8,027 1,665,258
2 2013-06-06 2013-06-09 8,026 4,152,290

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Biocide - Bactron K 139 Champion Technologies Biocide
Glutaraldehyde 111-30-8 5.00 0.05
Ethanol 64-17-5 5.00
Quaternary ammonium compounds,
benzyl-C12-16-alkyldimethyl, chlorides
68424-85-1 10.00
Hydrochloric Acid 28 Halliburton Energy Services Acid
Water

7732-18-5 85
Hydrochloric acid 7647-01-0 0.36
Sand (Proppant) Halliburton Energy Services Propping Agent Quartz 14808-60-7 99.90 31.03
FRW-66 Halliburton Energy Services Friction Reducer
Hydrotreated Light Distillate
64742-47-8
0.08
Gyptron T-390 Champion Technologies Halliburton Energy Services Scale Inhibitor Methanol

67-56-1 10.00
0.00800000
Gyptron T-390 Champion Technologies Scale Inhibitor
Water Base Fluid Fresh Water 100.00 68.47
2 BA-40L Halliburton Buffering Agent Potassium Carbonate 584-08-7 60 0.001 0
Gyptron T-390 Champion Technologies Scale Inhibitor Methanol 67-56-1 10 0.001 0
Bactron K-139 Champion Technologies Biocide Ethanol 64-17-5 5 0.002 0
Glutaraldehyde 111-30-8 5 0.002 0
Quaternary ammonium compounds,
benzyl-C-12-16 alkyldimethyl, chlorides
68424-85-1 10 0.004 0
FR-66 Halliburton Friction Reducer Hydrotreated Light Petroleum Distillate 64742-47-8 30 0.03 0
Water Provided by Customer Base Fluid Fresh Water 0000-00-0 100 99.81 0
Hydrochloric Acid 10-30% Halliburton Acid Hydrochloric Acid 7647-01-0 30 0.2 0

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2010 CHIEF OIL & GAS LLC 0.00 0 0.00 0 0.00 0
2011 CHIEF OIL & GAS LLC 0.00 0 0.00 0 0.00 0
2012 CHIEF OIL & GAS LLC 0.00 0 0.00 0 0.00 0
2013 CHIEF OIL & GAS LLC 786,720.00 61 0.00 0 0.00 0
2014 CHIEF OIL & GAS LLC 2,196,606.00 292 0.00 0 0.00 0
2015 CHIEF OIL & GAS LLC 1,123,137.42 310 0.00 0 0.00 0
2016 CHIEF OIL & GAS LLC 1,196,086.78 308 0.00 0 0.00 0
2017 CHIEF OIL & GAS LLC 991,816.62 362 0.00 0 0.00 0
2018 CHIEF OIL & GAS LLC 511,151.77 360 0.00 0 0.00 0
2019 CHIEF OIL & GAS LLC 470,791.16 365 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2012 CHIEF OIL & GAS LLC Fracing Fluid Waste 937.00 Bbl REUSE OTHER THAN ROAD SPREADING
2012 CHIEF OIL & GAS LLC Drilling Fluid Waste 1,030.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW018
2012 CHIEF OIL & GAS LLC Drill Cuttings 872.82 Tons LANDFILL 301358
2012 CHIEF OIL & GAS LLC Drill Cuttings 472.41 Tons LANDFILL 100933
2013 CHIEF OIL & GAS LLC Produced Fluid 545.00 Bbl REUSE OTHER THAN ROAD SPREADING
2013 CHIEF OIL & GAS LLC Fracing Fluid Waste 3,635.00 Bbl REUSE OTHER THAN ROAD SPREADING
2013 CHIEF OIL & GAS LLC Fracing Fluid Waste 41.33 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NC006
2013 CHIEF OIL & GAS LLC Fracturing Fluid Waste 16.83 Tons RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC006
2014 CHIEF OIL & GAS LLC Fracing Fluid Waste 180.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2014 CHIEF OIL & GAS LLC Produced Fluid 2,821.46 Bbl REUSE OTHER THAN ROAD SPREADING
2015 CHIEF OIL & GAS LLC Produced Fluid 2,783.94 Bbl REUSE OTHER THAN ROAD SPREADING
2016 CHIEF OIL & GAS LLC Produced Fluid 806.45 Bbl REUSE OTHER THAN ROAD SPREADING
2017 CHIEF OIL & GAS LLC Produced Fluid 49.70 Bbl STORAGE PENDING DISPOSAL OR REUSE
2017 CHIEF OIL & GAS LLC Produced Fluid 404.48 Bbl REUSE (AT WELL PAD)
2018 CHIEF OIL & GAS LLC Produced Fluid 87.66 Bbl REUSE (AT WELL PAD)
2019 CHIEF OIL & GAS LLC Produced Fluid 148.57 Bbl REUSE (AT WELL PAD)

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2016710 Primary Facility 2011-10-25 Routine/Complete Inspection No Violations Noted
2028377 Primary Facility 2011-12-20 Routine/Complete Inspection No Violations Noted
2094842 Primary Facility 2012-08-21 Routine/Complete Inspection No Violations Noted Drill rig recently moved out. Coiled tubing rig coming to drill out plugs and then flow back. Site looked good.
2112842 Primary Facility 2012-10-26 Routine/Complete Inspection No Violations Noted
2160865 Primary Facility 2013-04-23 Routine/Complete Inspection No Violations Noted
2177916 Primary Facility 2013-06-25 Routine/Complete Inspection No Violations Noted
2225620 Primary Facility 2013-12-02 Routine/Partial Inspection No Violations Noted
2231212 Primary Facility 2013-12-19 Routine/Complete Inspection No Violations Noted
2235972 Primary Facility 2014-01-13 Routine/Complete Inspection No Violations Noted
2240559 Primary Facility 2014-01-29 Routine/Complete Inspection No Violations Noted
2254023 Primary Facility 2014-03-13 Routine/Complete Inspection No Violations Noted
2269145 Primary Facility 2014-05-08 Routine/Complete Inspection No Violations Noted
2278061 Primary Facility 2014-06-11 Routine/Complete Inspection No Violations Noted
2280697 Primary Facility 2014-06-21 Drilling/Alteration No Violations Noted
2379163 Primary Facility 2015-06-12 Routine/Complete Inspection No Violations Noted Arrived on site at 13:30 and departed at 13:50. Weather conditions were sunny and ~85°F. No Chesapeake representatives were present during the inspection.
2385623 Primary Facility 2015-07-07 Routine/Complete Inspection No Violations Noted : Arrived @ 13:24 with OGI Andy Becher for a routine inspection. Weather: hot and humid following storms the previous day. Chief’s Kevin Hadlock was onsite during our inspection. All six wells were in production with 13-3/8” x 9-5/8”, and 9-5/8” x 5-1/2” annuli plumbed into poly tanks. For results see back. Water in cellar no bubbling. Field monitoring revealed no combustible gas on either annulis.
2538806 Primary Facility 2016-11-23 Site Restoration No Violations Noted Restoration inspection conducted in response to well site restoration reports filed by Chief Oil & Gas, LLC on November 22, 2016.

Interim restoration has been implemented on the well pad. A significant portion of the pad surface has been decompacted and vegetated. The most recent waste report for the subject facilities was submitted to the Department's Oil and Gas Reporting Electronic (OGRE) system on August 8, 2016. A Notice of Termination (NOT) for the erosion and sediment control permit associated with the site was approved by the Department on October 19, 2016.

Based on the information above and site conditions observed during the NOT inspection, these restoration reports are acknowledged.

2577013 Primary Facility 2017-03-30 Routine/Complete Inspection No Violations Noted Six Wells in production status. Six separators within containment. No leaks detected from production equipment. Site stabilized in all areas not needed for access to production equipment or wellheads. A well line was recently run to the well site. No violations noted.
2656900 Primary Facility 2017-11-03 Routine/Complete Inspection No Violations Noted Arrived at 13:00. Weather: cloudy with some rain. No personnel on site. 6 producing wells on location. Annuli venting to 550-gallon polytanks with vent stacks. The stacks were too high to monitor for combustible gas. All cellars filled with gravel. Analog gauges 0-5000 psi.

1H. Top gauge:1100 psi 3H. Top gauge 1050 psi 4H. Top gauge:1000 psi 2H. Top gauge:1100 psi 5H: Top gauge: 1150 psi 6H. Top gauge: 1050 psi. Well pad partially covered with grass. No violations were observed at this time.

2680180 Primary Facility 2018-01-09 Routine/Complete Inspection No Violations Noted Arrived at 1:10. Weather: sunny with blue skies. There are six producing wells on this pad. The Pad has been partly grassed. Top gauges on each of the six Wells were approximately 1000 psi (0 to 5000 psi analog). Annular vents were open to poly tanks. I was unable to monitor methane at the polytank openings. No violations were observed during my inspection.
2722865 Primary Facility 2018-04-25 Routine/Complete Inspection No Violations Noted The Dehydration units are being replaced. The larger units are being swapped out for smaller units.
2827055 Primary Facility 2019-01-14 Routine/Complete Inspection No Violations Noted Arrived onsite for a routine inspection at 09:46; the weather was ~15°F and calm. The gate was open when I arrived.

There were 6 properly tagged Marcellus wells staged for production. The well cellars were filled with gravel. There were 6 GPUs and 6 produced water tanks onsite and in secondary containment. The well annuli were plumbed to 4 poly tanks not on additional secondary containment.

Areas around the well site were greater than 70% uniform, perennial, vegetative cover. The pad had been reduced and was almost completely revegetated. Some steeper slopes were stabilized with rock lining.

No violations were noted at the time of inspection.

For data sources see[8]