If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-113-20082 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.522058,"lon":-76.414364,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Sullivan | |
Municipality: Cherry Township | |
Operator Name: CHIEF OIL & GAS LLC | |
Well Pad ID: 146346 | |
Farm/Lease Name: DACHEUX UNIT 1H | |
License Status: | |
Spud Date: 2012-06-05 | |
Permit Date: 2010-12-17 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: Yes | |
Latitude: 41.522058 | |
Longitude: -76.414364 |
Date | Event |
---|---|
2010-12-17 | New Permit Application |
2011-12-07 | Permit Renewal Application |
2012-06-15 | Performed Spud Operation |
2012-07-18 | Drilling Completion |
2012-10-18 | DEVIATED |
For data sources see[4]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2012-08-11 | 2012-08-11 | 8,027 | 1,665,258 | |
2 | 2013-06-06 | 2013-06-09 | 8,026 | 4,152,290 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | Biocide - Bactron K 139 | Champion Technologies | Biocide | |||||
Glutaraldehyde | 111-30-8 | 5.00 | 0.05 | |||||
Ethanol | 64-17-5 | 5.00 | ||||||
Quaternary ammonium compounds, benzyl-C12-16-alkyldimethyl, chlorides |
68424-85-1 | 10.00 | ||||||
Hydrochloric Acid 28 | Halliburton Energy Services | Acid | ||||||
Water 7732-18-5 85 |
||||||||
Hydrochloric acid | 7647-01-0 | 0.36 | ||||||
Sand (Proppant) | Halliburton Energy Services | Propping Agent | Quartz | 14808-60-7 | 99.90 | 31.03 | ||
FRW-66 | Halliburton Energy Services | Friction Reducer | ||||||
Hydrotreated Light Distillate 64742-47-8 |
0.08 | |||||||
Gyptron T-390 Champion Technologies | Halliburton Energy Services | Scale Inhibitor | Methanol 67-56-1 10.00 |
0.00800000 | ||||
Gyptron T-390 Champion Technologies | Scale Inhibitor | |||||||
Water | Base Fluid | Fresh Water | 100.00 | 68.47 | ||||
2 | BA-40L | Halliburton | Buffering Agent | Potassium Carbonate | 584-08-7 | 60 | 0.001 | 0 |
Gyptron T-390 | Champion Technologies | Scale Inhibitor | Methanol | 67-56-1 | 10 | 0.001 | 0 | |
Bactron K-139 | Champion Technologies | Biocide | Ethanol | 64-17-5 | 5 | 0.002 | 0 | |
Glutaraldehyde | 111-30-8 | 5 | 0.002 | 0 | ||||
Quaternary ammonium compounds, benzyl-C-12-16 alkyldimethyl, chlorides |
68424-85-1 | 10 | 0.004 | 0 | ||||
FR-66 | Halliburton | Friction Reducer | Hydrotreated Light Petroleum Distillate | 64742-47-8 | 30 | 0.03 | 0 | |
Water | Provided by Customer | Base Fluid | Fresh Water | 0000-00-0 | 100 | 99.81 | 0 | |
Hydrochloric Acid 10-30% | Halliburton | Acid | Hydrochloric Acid | 7647-01-0 | 30 | 0.2 | 0 |
For data sources see[5]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2010 | CHIEF OIL & GAS LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2011 | CHIEF OIL & GAS LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2012 | CHIEF OIL & GAS LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2013 | CHIEF OIL & GAS LLC | 786,720.00 | 61 | 0.00 | 0 | 0.00 | 0 |
2014 | CHIEF OIL & GAS LLC | 2,196,606.00 | 292 | 0.00 | 0 | 0.00 | 0 |
2015 | CHIEF OIL & GAS LLC | 1,123,137.42 | 310 | 0.00 | 0 | 0.00 | 0 |
2016 | CHIEF OIL & GAS LLC | 1,196,086.78 | 308 | 0.00 | 0 | 0.00 | 0 |
2017 | CHIEF OIL & GAS LLC | 991,816.62 | 362 | 0.00 | 0 | 0.00 | 0 |
2018 | CHIEF OIL & GAS LLC | 511,151.77 | 360 | 0.00 | 0 | 0.00 | 0 |
2019 | CHIEF OIL & GAS LLC | 470,791.16 | 365 | 0.00 | 0 | 0.00 | 0 |
For data sources see[6]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2012 | CHIEF OIL & GAS LLC | Fracing Fluid Waste | 937.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2012 | CHIEF OIL & GAS LLC | Drilling Fluid Waste | 1,030.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123SW018 |
2012 | CHIEF OIL & GAS LLC | Drill Cuttings | 872.82 Tons | LANDFILL | 301358 |
2012 | CHIEF OIL & GAS LLC | Drill Cuttings | 472.41 Tons | LANDFILL | 100933 |
2013 | CHIEF OIL & GAS LLC | Produced Fluid | 545.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2013 | CHIEF OIL & GAS LLC | Fracing Fluid Waste | 3,635.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2013 | CHIEF OIL & GAS LLC | Fracing Fluid Waste | 41.33 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NC006 |
2013 | CHIEF OIL & GAS LLC | Fracturing Fluid Waste | 16.83 Tons | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC006 |
2014 | CHIEF OIL & GAS LLC | Fracing Fluid Waste | 180.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123 |
2014 | CHIEF OIL & GAS LLC | Produced Fluid | 2,821.46 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2015 | CHIEF OIL & GAS LLC | Produced Fluid | 2,783.94 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016 | CHIEF OIL & GAS LLC | Produced Fluid | 806.45 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2017 | CHIEF OIL & GAS LLC | Produced Fluid | 49.70 Bbl | STORAGE PENDING DISPOSAL OR REUSE | |
2017 | CHIEF OIL & GAS LLC | Produced Fluid | 404.48 Bbl | REUSE (AT WELL PAD) | |
2018 | CHIEF OIL & GAS LLC | Produced Fluid | 87.66 Bbl | REUSE (AT WELL PAD) | |
2019 | CHIEF OIL & GAS LLC | Produced Fluid | 148.57 Bbl | REUSE (AT WELL PAD) |
For data sources see[7]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2016710 | Primary Facility | 2011-10-25 | Routine/Complete Inspection | No Violations Noted | |
2028377 | Primary Facility | 2011-12-20 | Routine/Complete Inspection | No Violations Noted | |
2094842 | Primary Facility | 2012-08-21 | Routine/Complete Inspection | No Violations Noted | Drill rig recently moved out. Coiled tubing rig coming to drill out plugs and then flow back. Site looked good. |
2112842 | Primary Facility | 2012-10-26 | Routine/Complete Inspection | No Violations Noted | |
2160865 | Primary Facility | 2013-04-23 | Routine/Complete Inspection | No Violations Noted | |
2177916 | Primary Facility | 2013-06-25 | Routine/Complete Inspection | No Violations Noted | |
2225620 | Primary Facility | 2013-12-02 | Routine/Partial Inspection | No Violations Noted | |
2231212 | Primary Facility | 2013-12-19 | Routine/Complete Inspection | No Violations Noted | |
2235972 | Primary Facility | 2014-01-13 | Routine/Complete Inspection | No Violations Noted | |
2240559 | Primary Facility | 2014-01-29 | Routine/Complete Inspection | No Violations Noted | |
2254023 | Primary Facility | 2014-03-13 | Routine/Complete Inspection | No Violations Noted | |
2269145 | Primary Facility | 2014-05-08 | Routine/Complete Inspection | No Violations Noted | |
2278061 | Primary Facility | 2014-06-11 | Routine/Complete Inspection | No Violations Noted | |
2280697 | Primary Facility | 2014-06-21 | Drilling/Alteration | No Violations Noted | |
2379163 | Primary Facility | 2015-06-12 | Routine/Complete Inspection | No Violations Noted | Arrived on site at 13:30 and departed at 13:50. Weather conditions were sunny and ~85°F. No Chesapeake representatives were present during the inspection. |
2385623 | Primary Facility | 2015-07-07 | Routine/Complete Inspection | No Violations Noted | : Arrived @ 13:24 with OGI Andy Becher for a routine inspection. Weather: hot and humid following storms the previous day. Chief’s Kevin Hadlock was onsite during our inspection. All six wells were in production with 13-3/8” x 9-5/8”, and 9-5/8” x 5-1/2” annuli plumbed into poly tanks. For results see back. Water in cellar no bubbling. Field monitoring revealed no combustible gas on either annulis. |
2538806 | Primary Facility | 2016-11-23 | Site Restoration | No Violations Noted | Restoration inspection conducted in response to well site restoration reports filed by Chief Oil & Gas, LLC on November 22, 2016.
Interim restoration has been implemented on the well pad. A significant portion of the pad surface has been decompacted and vegetated. The most recent waste report for the subject facilities was submitted to the Department's Oil and Gas Reporting Electronic (OGRE) system on August 8, 2016. A Notice of Termination (NOT) for the erosion and sediment control permit associated with the site was approved by the Department on October 19, 2016. Based on the information above and site conditions observed during the NOT inspection, these restoration reports are acknowledged. |
2577013 | Primary Facility | 2017-03-30 | Routine/Complete Inspection | No Violations Noted | Six Wells in production status. Six separators within containment. No leaks detected from production equipment. Site stabilized in all areas not needed for access to production equipment or wellheads. A well line was recently run to the well site. No violations noted. |
2656900 | Primary Facility | 2017-11-03 | Routine/Complete Inspection | No Violations Noted | Arrived at 13:00. Weather: cloudy with some rain. No personnel on site. 6 producing wells on location. Annuli venting to 550-gallon polytanks with vent stacks. The stacks were too high to monitor for combustible gas. All cellars filled with gravel. Analog gauges 0-5000 psi.
1H. Top gauge:1100 psi 3H. Top gauge 1050 psi 4H. Top gauge:1000 psi 2H. Top gauge:1100 psi 5H: Top gauge: 1150 psi 6H. Top gauge: 1050 psi. Well pad partially covered with grass. No violations were observed at this time. |
2680180 | Primary Facility | 2018-01-09 | Routine/Complete Inspection | No Violations Noted | Arrived at 1:10. Weather: sunny with blue skies. There are six producing wells on this pad. The Pad has been partly grassed. Top gauges on each of the six Wells were approximately 1000 psi (0 to 5000 psi analog). Annular vents were open to poly tanks. I was unable to monitor methane at the polytank openings. No violations were observed during my inspection. |
2722865 | Primary Facility | 2018-04-25 | Routine/Complete Inspection | No Violations Noted | The Dehydration units are being replaced. The larger units are being swapped out for smaller units. |
2827055 | Primary Facility | 2019-01-14 | Routine/Complete Inspection | No Violations Noted | Arrived onsite for a routine inspection at 09:46; the weather was ~15°F and calm. The gate was open when I arrived.
There were 6 properly tagged Marcellus wells staged for production. The well cellars were filled with gravel. There were 6 GPUs and 6 produced water tanks onsite and in secondary containment. The well annuli were plumbed to 4 poly tanks not on additional secondary containment. Areas around the well site were greater than 70% uniform, perennial, vegetative cover. The pad had been reduced and was almost completely revegetated. Some steeper slopes were stabilized with rock lining. No violations were noted at the time of inspection. |
For data sources see[8]