37-113-20049

Well Details

Well ID: 37-113-20049
Loading map...
Country: United States
State: Pennsylvania
County: Sullivan
Municipality: Shrewsbury Township
Operator Name: EXCO RESOURCES PA LLC
Well Pad ID: 146906
Farm/Lease Name: WISTAR SHAFFER TRACTS UNIT 1H
License Status:
Spud Date: 2010-11-01
Permit Date: 2010-10-14
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.346492
Longitude: -76.630050

For data sources see[1][2][3]

Well History

Date Event
2010-10-14 New Permit Application
2010-10-22 Performed Spud Operation
2010-11-24 Drilling Completion
2011-01-27 Perforation
2011-03-17 DEVIATED

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2012-09-13 2012-09-13 8,496 3,957,820

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 DWP-901 Calfrac Well Services Breaker
DWP-204 Clay Control Calfrac Well Services pH Buffer
Hydrochloric Acid Calfrac Well Services Clean Perforations Nonionic surfactant 5.00 0.00563000
Goethite 1310-14-1 0.10 0.00560000
Oxyalkylated polyamine 5.00 0.00105000
Acetic acid 64-19-7 1.00 0.00021000
Apatite 64476-38-6 0.10 0.00274000
2,2-Dibromo-3-nitrilopropionamide 10222-01-2 40.00 0.01
Biotite 1302-27-8 0.10 0.00274000
Quaternary ammonium compounds,
bis(hydrogenated tallow alkyl)dimethyl,
salts with bentonite
68953-58-2 5.00 0.00001000
Quartz 14808-60-7 100.00 15.56
Carbonic acid calcium salt (1:1) 471-34-1 1.00 0.03
Organic phosphonate 1 30.00 0.00627000
Organic phosphonate 2 10.00 0.00209000
Sodium chloride 7647-14-5 1.00 0.00001000
Thiourea polymer 68527-49-1 30.00 0.00044000
Amine salt 5.00 0.00105000
Polyethylene glycol 25322-68-3 70.00 0.01
Formalin 50-00-0 0.10 0.00003000
Ammonium chloride 12125-02-9 10.00 0.00125000
Guar gum 9000-30-0 60.00 0.00011000
Citric acid 77-92-9 60.00 0.00315000
Propargyl Alcohol 10.00 0.00015000
Distillates, petroleum, hydrotreated light 64742-47-8 30.00 0.03
Oxirane, 2-methyl-, polymer with oxirane, monodecyl ether 37251-67-5 1.50 0.00
Distillates, petroleum, hydrotreated middle 64742-46-7 60.00 0.00011000
Illite 12173-60-3 1.00 0.00355000
Formic acid 64-18-6 13.00 0.00001000
Polyacrylamide polymer 40.00 0.04
Hydrochloric acid 7647-01-0 37.00 0.31
Olefin 5.00 0.00007000
Ilmenite (FeTiO3), conc. 98072-94-7 0.10 0.00131000
Polyoxyalkylenes 30.00 0.00044000
Peroxydisulfuric acid, diammonium salt 7727-54-0 100.00 0.00004000
Polyoxyalkylenes surfactant 5.00 0.00563000
Fatty acids 30.00 0.00044000
Methanol 67-56-1 60.00 0.00715000
DWP-612 Calfrac Well Services Friction Reducer
Sand (Proppant) Calfrac Well Services Propping Agent
DAP-925 Calfrac Well Services Acid Corrosion Inhibitor
DAP-901 Calfrac Well Services Scale Inhibitor
DWP-111 Calfrac Well Services Gel Slurry
Water BaseFluid/Mix Water Water 7732-18-5 100.00 83.98
DWP-944 Calfrac Well Services Biocide
DAP-103 Calfrac Well Services Iron Control

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2010 CHIEF OIL & GAS LLC 0.00 0 0.00 0 0.00 0
2011 EXCO RESOURCES PA LLC 0.00 0 0.00 0 0.00 0
2012 EXCO RESOURCES PA LLC 0.00 0 0.00 0 0.00 0
2013 EXCO RESOURCES PA LLC 0.00 0 0.00 0 0.00 0
2014 EXCO RESOURCES PA LLC 2,415,727.00 365 0.00 0 0.00 0
2015 EXCO RESOURCES PA LLC 1,378,480.00 337 0.00 0 0.00 0
2016 EXCO RESOURCES PA LLC 934,295.00 285 0.00 0 0.00 0
2017 EXCO RESOURCES PA LLC 861,988.00 337 0.00 0 0.00 0
2018 EXCO RESOURCES PA LLC 724,034.00 355 0.00 0 0.00 0
2019 EXCO RESOURCES PA LLC 503,788.00 294 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2010 CHIEF OIL & GAS LLC Produced Fluid 192.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW018
2010 CHIEF OIL & GAS LLC Fracing Fluid Waste 200.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR119
2010 CHIEF OIL & GAS LLC Drilling Fluid Waste 238.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0008451
2011 CHIEF OIL & GAS LLC Fracing Fluid Waste 480.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR119
2011 EXCO RESOURCES PA LLC Drilling Fluid Waste 2,755.52 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR119
2012 EXCO RESOURCES PA LLC Fracturing Fluid Waste 133.51 Tons LANDFILL 301358
2012 EXCO RESOURCES PA LLC Fracing Fluid Waste 3,514.00 Bbl REUSE OTHER THAN ROAD SPREADING
2012 EXCO RESOURCES PA LLC Drill Cuttings 15.87 Tons LANDFILL 301358
2013 EXCO RESOURCES PA LLC Produced Fluid 604.70 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR119
2013 EXCO RESOURCES PA LLC Fracturing Fluid Waste 22.08 Tons LANDFILL 301358
2014 EXCO RESOURCES PA LLC Produced Fluid 440.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR119
2014 EXCO RESOURCES PA LLC Produced Fluid 219.50 Bbl INJECTION DISPOSAL WELL PAS2D205BCLE
2014 EXCO RESOURCES PA LLC Produced Fluid 157.10 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC024
2014 EXCO RESOURCES PA LLC Produced Fluid 110.00 Bbl REUSE OTHER THAN ROAD SPREADING
2014 EXCO RESOURCES PA LLC Produced Fluid 431.90 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC010
2015 EXCO RESOURCES PA LLC Produced Fluid 659.50 Bbl INJECTION DISPOSAL WELL PAS2D205BCLE
2016 EXCO RESOURCES PA LLC Produced Fluid 595.00 Bbl INJECTION DISPOSAL WELL PAS2D205BCLE
2017 EXCO RESOURCES PA LLC Produced Fluid 495.00 Bbl INJECTION DISPOSAL WELL PAS2D205BCLE
2018 EXCO RESOURCES PA LLC Produced Fluid 300.00 Bbl INJECTION DISPOSAL WELL PAS2D205BCLE
2018 EXCO RESOURCES PA LLC Produced Fluid 200.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2019 EXCO RESOURCES PA LLC Produced Fluid 425.00 Bbl INJECTION DISPOSAL WELL PAS2D205BCLE
2019 EXCO RESOURCES PA LLC Produced Fluid 55.00 Bbl REUSE (AT WELL PAD)

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1930756 Primary Facility 2010-11-30 Routine/Complete Inspection Violation(s) Noted
1939429 Primary Facility 2010-12-28 Follow-up Inspection No Violations Noted
1965495 Primary Facility 2011-04-13 Routine/Complete Inspection Violation(s) Noted
1987088 Primary Facility 2011-07-07 Routine/Complete Inspection Pending well is bubbling in cellar source undetectable because of water, frac tanks have insufficient containment no well tag
1992487 Primary Facility 2011-08-02 Routine/Complete Inspection Pending 1st sign - EXCO, 2nd - right outside pad - Chief and well tag on ground is Chief
2033407 Primary Facility 2012-01-09 Routine/Complete Inspection Violation(s) Noted
2034445 Primary Facility 2011-01-11 Routine/Complete Inspection Pending
2039330 Primary Facility 2012-02-02 Follow-up Inspection Pending
2040476 Primary Facility 2012-02-06 Routine/Partial Inspection Violation(s) Noted
2050249 Primary Facility 2012-03-13 Follow-up Inspection Violation(s) Noted
2054017 Primary Facility 2012-03-23 Follow-up Inspection Outstanding Violations - No Viols Req'd
2060285 Primary Facility 2012-04-18 Routine/Partial Inspection No Violations Noted
2062462 Primary Facility 2012-04-25 Routine/Complete Inspection Outstanding Violations - No Viols Req'd
2070894 Primary Facility 2012-05-24 Routine/Complete Inspection No Violations Noted
2107836 Primary Facility 2012-10-15 Routine/Complete Inspection No Violations Noted
2114081 Primary Facility 2012-11-06 Routine/Complete Inspection No Violations Noted
2117169 Primary Facility 2012-11-20 Routine/Complete Inspection No Violations Noted
2261960 Primary Facility 2014-04-09 Routine/Complete Inspection No Violations Noted
2367899 Primary Facility 2015-04-29 Routine/Complete Inspection No Violations Noted Arrived at 15:10. I well in production cellar dry and full of gravel so it was not possible to look for bubbling. There were two annular vents. One with a 1”-diameter pipe, the other a 2” pipe. Both vents appeared to be shut-in to a 0-2000 psi water filled gauge. Both gauges read 0. There appeared to be a third annular vent shut in to a 0-5000 psi gauge. This also read 0.
2477383 Primary Facility 2016-04-22 Routine/Complete Inspection No Violations Noted Routine inspection conducted to assess general site conditions. No EXCO representatives were present during the inspection.

Vegetative cover on the site is largely grater than 70% perennial vegetation, though a few areas with less coverage were observed in the vicinity of the well pad. Most temporary erosion and sediment control BMPs have been removed, though some are present along the access road and the perimeter of the well pad. No evidence of accellerated erosion or sedimentation was observed.

A large bundle of containment and two barrels are being stored on the well pad. The barrels were not in containment, and the content of the barrels is not known. These barrels should be removed or placed within containment. Title 58 Pa. C.S. § 3216 (2012 Oil and Gas Act) requires that non-production related equipment and materials be removed from a well site within 90 days of completion of drilling, unless express written approval of the landowner is given to store such items. If no landowner consent has been g

2550452 Primary Facility 2017-01-05 Routine/Complete Inspection No Violations Noted Arrived at 12:00. Weather: cloudy, cold. There was one producing well on location. A well-tender was onsite at the time of my inspection. Cellar dry and full of gravel. Annular vents were open. No combustible gas was detected (monitored with Altair 5X gas meter calibrated on 01/05/17). Left location at 12:45.
2565516 Primary Facility 2017-02-28 Routine/Complete Inspection No Violations Noted No violations cited at time of inspection, though violations may be cited if EXCO does not remove non-production related materials stored on site or provide documentation of landowner consent for the storage of those materials.
2619551 Primary Facility 2017-07-27 Routine/Complete Inspection No Violations Noted One well in production status. One each sand and water separator. No leaks from production equipment. Site stable. No violations noted.
2697091 Primary Facility 2018-02-22 Routine/Complete Inspection No Violations Noted One well staged for production phase. One each sand and water separator. No leaks detected from production equipment. No violations noted.
2813467 Primary Facility 2018-12-10 Routine/Complete Inspection No Violations Noted Arrived onsite for a routine inspection at 11:43; the weather was ~30°F and calm.

There was 1 properly tagged Marcellus well staged for production. The well cellar was filled with gravel. There was 1 GPU and 1 produced water tank onsite.

Overall, the site was well vegetated and appeared stable. However, an area of filter sock on the northwest corner of the pad showed signs of erosion. This section of filter sock also appeared to have been overtopped by sediment at some point, see photos. There was also a mower deck left near the north edge of the pad.

It is recommended that temporary E&S controls be inspected more thoroughly and maintained more regularly to prevent issues like those noted in the attached photos.

No violations noted.

2845541 Primary Facility 2019-02-27 Routine/Complete Inspection No Violations Noted One well staged for production. One separator. No leaks. Site snow covered and stable.

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
1930756 600442 11/30/2010 2010-11-30 102.4HQBMP - Failure to implement Special Protection BMPs for HQ or EV stream. Administrative
1930756 600443 11/30/2010 2010-11-30 201G - Failure to post permit number, operator name, address, telephone number in a conspicuous manner at the site during drilling Administrative
1930756 600444 11/30/2010 2010-11-30 401 CSL - Discharge of pollultional material to waters of Commonwealth. Environmental Health & Safety
1965495 608812 04/13/2011 2011-04-13 201H - Failure to properly install the permit number, issued by the department, on a completed well. Administrative
2033407 628994 01/09/2012 2012-01-09 SWMA301 - Failure to properly store, transport, process or dispose of a residual waste. Environmental Health & Safety 7 Baker tanks full of high conductivity fluid located to side of access road, not on pad. Location: 41, 20', 44.1", 76, 38', 01.2" . This constitutes an unpermitted transfer station. the site was referred to the Department's Waste Management Program.
2040476 631400 02/06/2012 2012-02-06 102.4NOPLAN - No E&S plan developed, plan not on site Administrative
2040476 631401 02/06/2012 2012-02-06 102.4INADPLN - E&S Plan not adequate Administrative
2050249 634179 03/13/2012 2012-03-13 78.86* - Failure to report defective, insufficient, or improperly cemented casing w/in 24 hrs or submit plan to correct w/in 30 days Administrative Inside Surface Csg. (13x9) annulus

Penalties Applied

Violation ID Penalty ID Penalty Code Penalty Status Penalty Date Enforcement Date Penalty Amount Amount Collected
628994 293717 CACP - Consent Assessment of Civil Penalty Comply/Closed 2013-02-06 2013-02-06 $25,000.00 $25,000.00
631400 281525 NOV - Notice of Violation Administrative Close Out 2012-05-24
631400 293717 CACP - Consent Assessment of Civil Penalty Comply/Closed 2013-02-06 2013-02-06 $25,000.00 $25,000.00
631401 281525 NOV - Notice of Violation Administrative Close Out 2012-05-24
631401 293717 CACP - Consent Assessment of Civil Penalty Comply/Closed 2013-02-06 2013-02-06 $25,000.00 $25,000.00