37-105-21716

Well Details

Well ID: 37-105-21716
Loading map...
Country: United States
State: Pennsylvania
County: Potter
Municipality: Sweden Township
Operator Name: SENECA RESOURCES CO LLC
Well Pad ID: 148178
Farm/Lease Name: DCNR 001 7H 50372
License Status:
Spud Date:
Permit Date: 2010-08-26
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.777525
Longitude: -77.867997

For data sources see[1][2][3]

Well History

Date Event
2010-08-26 New Permit Application
2010-09-03 Performed Spud Operation
2010-11-08 Drilling Completion
2011-04-12 Perforation
2013-04-04 DEVIATED

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2011-04-06 2011-04-12 5,840 4,488,920 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 ScaleHib 100 Universal Well Services Scale Inhibitor Ethylene Glycol 107-21-1 60 0.0141394 6022.22
CMHPG Universal Well Services Aqueous Gellant Guar Gum 68130-15-4 8.3 0.00207343 883.11
FRP - 121 Universal Well Services Friction Reducer Sodium Perborate 7632-04-4 98.6 0.209288 89139.2
Sodium Metaborate 7775-19-1 1.4 0.00297163 1265.67
15% HydroChloric Acid Universal Well Services Acid Hydrochloric Acid HCl 7647-01-0 15 0.101638 43289.4
Proppant 40/70 Ottawa Universal Well Services Proppant Crystalline silica (quartz) 14808-60-7 100 4.40062 1,874,300.0
Water Seneca Resources Carrier/Base Fluid Water 7732-18-5 100 87.9515 37,460,000.0
Proppant 30/50 Ottawa Universal Well Services Proppant Crystalline silica (quartz) 14808-60-7 100 6.70952 2,857,700.0

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2010 SENECA RESOURCES CO LLC 0.00 0 0.00 0 0.00 0
2011 SENECA RESOURCES CO LLC 119,402.00 365 0.00 0 0.00 0
2012 SENECA RESOURCES CO LLC 263,100.00 356 0.00 0 0.00 0
2013 SENECA RESOURCES CO LLC 214,274.00 365 0.00 0 0.00 0
2014 SENECA RESOURCES CO LLC 172,528.00 363 0.00 0 0.00 0
2015 SENECA RESOURCES CO LLC 47,848.91 112 0.00 0 0.00 0
2016 SENECA RESOURCES CO LLC 66,108.97 89 0.00 0 0.00 0
2017 SENECA RESOURCES CO LLC 93,375.33 232 0.00 0 0.00 0
2018 SENECA RESOURCES CO LLC 51,326.78 75 0.00 0 0.00 0
2019 SENECA RESOURCES CO LLC 50,565.02 56 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2010 SENECA RESOURCES CO LLC Drill Cuttings 676.84 Tons LANDFILL 100361
2011 SENECA RESOURCES CO LLC Drill Cuttings 16.67 Tons LANDFILL 100361
2011 SENECA RESOURCES CO LLC Produced Fluid 8,976.00 Bbl REUSE OTHER THAN ROAD SPREADING
2012 SENECA RESOURCES CO LLC Produced Fluid 18,760.00 Bbl REUSE OTHER THAN ROAD SPREADING
2012 SENECA RESOURCES CO LLC Produced Fluid 22.00 Bbl INJECTION DISPOSAL WELL 34-155-21893
2012 SENECA RESOURCES CO LLC Produced Fluid 487.00 Bbl INJECTION DISPOSAL WELL 34-083-24072
2012 SENECA RESOURCES CO LLC Produced Fluid 23.00 Bbl INJECTION DISPOSAL WELL 34-155-21894
2012 SENECA RESOURCES CO LLC Produced Fluid 23.00 Bbl INJECTION DISPOSAL WELL 34-155-23203
2012 SENECA RESOURCES CO LLC Produced Fluid 347.00 Bbl INJECTION DISPOSAL WELL 34-155-23795
2012 SENECA RESOURCES CO LLC Produced Fluid 214.00 Bbl INJECTION DISPOSAL WELL 34-133-20525
2013 SENECA RESOURCES CO LLC Produced Fluid 13,146.00 Bbl REUSE OTHER THAN ROAD SPREADING
2014 SENECA RESOURCES CO LLC Produced Fluid 8,603.00 Bbl REUSE OTHER THAN ROAD SPREADING
2015 SENECA RESOURCES CO LLC Produced Fluid 1,789.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016 SENECA RESOURCES CO LLC Other Oil & Gas Wastes 42.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NW005
2017 SENECA RESOURCES CO LLC Produced Fluid 1,230.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2017 SENECA RESOURCES CO LLC Other Oil & Gas Wastes 55.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2017 SENECA RESOURCES CO LLC Produced Fluid 952.00 Bbl REUSE (AT WELL PAD)
2017 SENECA RESOURCES CO LLC Produced Fluid 60.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW005
2018 SENECA RESOURCES CO LLC Produced Fluid 400.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2018 SENECA RESOURCES CO LLC Produced Fluid 475.00 Bbl REUSE (AT WELL PAD)
2018 SENECA RESOURCES CO LLC Other Oil & Gas Wastes 25.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW005
2019 SENECA RESOURCES CO LLC Produced Fluid 50.00 Bbl REUSE (AT WELL PAD)
2019 SENECA RESOURCES CO LLC Produced Fluid 572.50 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2019 SENECA RESOURCES CO LLC Produced Fluid 102.50 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW005

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1931523 Primary Facility 2010-11-04 Drilling/Alteration No Violations Noted
1957940 Primary Facility 2011-03-16 Routine/Partial Inspection Violation(s) Noted No well record on file, Site ID sign missing some information, rat hole not filled in
1959454 Primary Facility 2011-03-17 Routine/Complete Inspection No Violations Noted
1963848 Primary Facility 2011-04-05 Follow-up Inspection No Violations Noted
2033013 Primary Facility 2012-01-09 Routine/Complete Inspection No Violations Noted An inspection was conducted on 1/9/12 at the DCNR Tract 001 - Pad H site in Sweden Township, Potter County. The site ID sign, ESCGP, and perimeter of the site were observed. The ground was frozen and mostly snow covered. No evidence of accelerated erosion was observed. Where visible, the slopes appeared stable and vegetated. In several areas on the pad surface, there were small amounts of a balck, shiny rock-like material spilled. Doug Kepler was contacted and provided pictures of the spilled material. Mr. Kepler informed the Department that the material is used for sandblasting and had been cleaned up the morning of 1/11/12. Recent weekly inspection records for this site were not in the mailbox for this site, this issue needs to be addressed. No new violations were cited during this inspection. - MRN
2164796 Primary Facility 2013-05-01 Routine/Partial Inspection No Violations Noted A routine inspection of the DCNR 001 Pad in Sweden Township, Potter County was conducted on May 1, 2012. All E&S controls remain in place and a record of inspections on behalf of Seneca was located in the mailbox with E&S plan. The last inspection documented on behalf of Seneca was listed as 4/23/2013. The site was stabilized and no evidence of accelerated erosion was observed. Several puddles on the pad surface were screened for elevated conductance; no elevated reading were observed. The 2H and 7H wells have been drilled and the 1H, 3H,4H,5H,6H,8H,9H,10H,11H,12H,13H,14H and 15H will are listed as Permitted But Not Materialized. No violations were cited during this inspection.
2398243 Primary Facility 2015-08-13 Routine/Complete Inspection No Violations Noted
2409571 Primary Facility 2015-09-22 Routine/Complete Inspection No Violations Noted The Department inspected the DCNR 001 Pad H on 9/21/15 @ 1300 hours. The weather was sunny 75 degrees. A site ID sign was observed at the entrance to the well site. The E&S plan and PPC plan were located in the mailbox. The site was last inspected by company personnel on 8/25/15 @ 700 hours. The site status was listed as “in production”.
2552797 Primary Facility 2017-01-17 Routine/Complete Inspection No Violations Noted
2582405 Primary Facility 2017-04-10 Routine/Complete Inspection No Violations Noted On 4/10/17 at 1402 hrs I conducted a routine inspection at the DCNR 001 Pad H well site. It was mostly sunny and 73 degrees F. No one was present during my inspection.

Two wells, the 2H and 7H, have been drilled and are in production; drilling of the wells was completed in November 2010. There have been no new well permits issued for the site for several years. It does not appear that the well site has been restored and the pad remains at nearly full size (approximately 300 feet x 600 feet), with the exception of the southeast pad corner where the impoundment was formerly located. Interim restoration of the well site should be completed as per 25 Pa Code Section 78a.65(a)(1).

On 2/29/16, Seneca submitted a Well Site Assessment Summary to the Department. The Summary milestones for Pad H included submittal of Well Site Restoration Reports (WSRRs) and the Notice of Termination (NOT) for the ESCGP. To date, neither the NOT or WSRRs have been received by the Department. If Seneca does not intend to conduct int

2613321 Primary Facility 2017-06-19 Routine/Complete Inspection No Violations Noted
2686245 Primary Facility 2018-01-24 Routine/Complete Inspection No Violations Noted At the time of this inspection this well was in production. The wellhead assembly all fittings and flow lines were tested for gas. The results of this testing was no gas was detected on the wellhead assembly or the well area.
2725211 Primary Facility 2018-05-01 Routine/Complete Inspection No Violations Noted A routine inspection at the DCNR 001 Pad H well site and the 1V 50258 monitoring pad was conducted on May 1, 2018. It was sunny and 68 degrees F. No one was present during this inspection.

Two wells, the 2H and 7H, have been drilled on Pad H and appear to be capable of producing. Drilling of the wells was completed in November 2010. The last active well permits expired in 2012. It does not appear that Pad H has been restored and the site remains at nearly full size (approximately 300 feet x 600 feet), with the exception of the southeast pad corner where the impoundment was formerly located. Silk sock remains in this area. Interim restoration of the well site should be completed in accordance with 25 Pa Code Section 78a.65(a)(1). To date, neither the NOT or WSRRs have been submitted to the DEP. If Seneca does not intend to conduct interim restoration of the Pad H site at this time, then a restoration extension request should be submitted to the Department as per 25 Pa Code Section 78a.65(c). Slopes surro

2767681 Primary Facility 2018-08-27 Routine/Complete Inspection No Violations Noted At the time of this inspection this well appeared to be in production. A digital gauge on the casing read 1127 psi( pounds per square inch )and a digital gauge on the tubing read 785 psi. A mechanical gauge on the 3" production line leaving the well head assembly,going into the ground and then into the production equipment read 900 psi. No violations noted at this inspection.

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
1957940 606771 03/16/2011 2011-03-16 201G - Failure to post permit number, operator name, address, telephone number in a conspicuous manner at the site during drilling Administrative
1957940 606772 03/16/2011 2011-03-16 78.65(1)* - Rat hole not filled Environmental Health & Safety
1957940 606773 03/16/2011 2011-03-16 78.122 - Drillers Log not on site Administrative

For data sources see[8]

References