Well Details

Well ID: 37-105-21288
Loading map...
Country: United States
State: Pennsylvania
County: Potter
Municipality: Ulysses Township
Operator Name: SUSQUEHANNA ENERGIES INC
Well Pad ID:
Farm/Lease Name: HOOPES 28
License Status: ACTIVE
Spud Date:
Permit Date: 2006-10-27
Well Type: GAS
Unconventional Well: N
Configuration: Vertical Well
Conservation: No
Latitude: 41.872712
Longitude: -77.775706

For data sources see[1][2][3]

Well History

Date Event
2006-10-27 New Permit Application
2007-05-30 Performed Spud Operation
2007-05-31 Drilling Completion
2007-08-23 NEWLY DRILLED
2007-10-15 Perforation

For data sources see[4]


Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2007 NORTH EAST GAS & OIL CO 337.00 19 0.00 0 0.00 0
2008 NORTH EAST GAS & OIL CO 2431.00 198 0.00 0 0.00 0
2009 NORTH EAST GAS & OIL CO 586.00 187 0.00 0 0.00 0
2010 NORTH EAST GAS & OIL CO 836.00 304 0.00 0 0.00 0
2011 NORTH EAST GAS & OIL CO 832.00 277 0.00 0 0.00 0
2012 NORTH EAST GAS & OIL CO 921.00 274 0.00 0 0.00 0
2013 NORTH EAST GAS & OIL CO 611.00 225 0.00 0 0.00 0
2014 SUSQUEHANNA ENERGIES INC 483.00 365 0.00 0 0.00 0
2015 SUSQUEHANNA ENERGIES INC 545.00 365 0.00 0 0.00 0
2016 SUSQUEHANNA ENERGIES INC 465.00 365 0.00 0 0.00 0
2017 SUSQUEHANNA ENERGIES INC 465.00 365 0.00 0 0.00 0
2018 SUSQUEHANNA ENERGIES INC 323.00 365 0.00 0 0.00 0

For data sources see[5]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2008 NORTH EAST GAS & OIL CO Fracking Fluid 52.00 Bbl Brine or Industrial Waste Treatment Plt PA0102784
2010 NORTH EAST GAS & OIL CO Produced Fluid 39.00 Bbl ROAD SPREADING
2011 NORTH EAST GAS & OIL CO Produced Fluid 5.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0102784
2011 NORTH EAST GAS & OIL CO Produced Fluid 23.00 Bbl ROAD SPREADING
2012 NORTH EAST GAS & OIL CO Produced Fluid 23.00 Bbl ROAD SPREADING
2013 NORTH EAST GAS & OIL CO Produced Fluid 6 Bbl CENT WASTE TRT FAC NPDES PA0102784
2013 NORTH EAST GAS & OIL CO Produced Fluid 14.00 Bbl ROAD SPREADING
2013 NORTH EAST GAS & OIL CO Produced Fluid 6.00 Bbl CENT WASTE TRT FAC NPDES DISCHARGE PA0102784
2017 SUSQUEHANNA ENERGIES INC Produced Fluid 5.00 Bbl CENT WASTE TRT FAC NPDES DISCHARGE PA0095273

For data sources see[6]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2132999 Primary Facility 2013-01-23 Routine/Partial Inspection No Violations Noted On January 23, 2013 an inspection was conducted of the Hoopes 28 well site in Ulysses Township, Potter County. No well tag was permenantly affixed to the well, this should be addressed as soon as possible. No other issues were evident at the time of this inspection and no violations were cited.
2511544 Primary Facility 2016-08-11 Routine/Complete Inspection No Violations Noted The Department of Environmental Protection (DEP) inspected the Susquehanna Energies Inc. Hoopes #28 well, API#105-21288, in Ulysses Twp., Potter Co. on 8/11/2016. The weather was 80° sun/passing clouds, humidity: 78%, and winds 4 mph WSW. The site was located in a farm field and appeared to be well vegetated. A polytank was observed adjacent to the well. A sign was affixed to the production equipment identifying the well; however a visible well tag was not observed on the well head. As per Section 3211(h) 58 Pa. C.S. §3201-3274 (relating to the Development) (“2012 Oil and Gas Act”) Labeling.--The well operator shall install the permit number issued by the department in a legible, visible and permanent manner on the well upon completion. No violations are noted at this time. Please contact me with any questions.
2590694 Primary Facility 2017-05-02 Routine/Complete Inspection No Violations Noted
2686197 Primary Facility 2018-01-24 Routine/Complete Inspection No Violations Noted At the time of this inspection this well was in production. The wellhead assembly all fittings and flow lines were tested for gas. Results of this testing was that no gas was detected on the wellhead assembly or the well area.
2816219 Primary Facility 2018-12-17 Routine/Complete Inspection No Violations Noted At the time of this inspection this well was in production. The wellhead assembly is a approximate 10" casing out of the ground threaded to an approximate 7"x2"x2" tee/ hammer style fitting. Out of one side of the tee style fitting is an approximate 2" valve that is shut and has a plug in the end of the valve. On the other side of the tee style fitting is an approximate 2" valve that is open and connected to an approximate 2" production line. The approximately 2" production line then flows to a separator type production equipment tank then into a meter and then into the ground. No violations noted at the time of this Inspection.

For data sources see[7]