X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-105-00533

Well Details

Well ID: 37-105-00533
Loading map...
Country: United States
State: Pennsylvania
County: Potter
Municipality: Genesee Township
Operator Name:
Well Pad ID:
Farm/Lease Name: M.A. HILL EW-404
License Status: ACTIVE
Spud Date:
Permit Date:
Well Type: STORAGE WELL
Unconventional Well: N
Configuration: Vertical Well
Conservation: No
Latitude: 41.929583
Longitude: -77.861716

For data sources see[1][2][3]

Well History

Date Event
1935-08-24 Drilling Completion
2001-03-21 OLD WELL

For data sources see[4]


Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
1992 NATL FUEL GAS SUPPLY CORP 0.00 0 0.00 0 0.00 0
2010 NATL FUEL GAS SUPPLY CORP 0.00 0 0.00 0 0.00 0
2011 NATL FUEL GAS SUPPLY CORP 0.00 0 0.00 0 0.00 0
2012 NATL FUEL GAS SUPPLY CORP 0.00 0 0.00 0 0.00 0
2013 NATL FUEL GAS SUPPLY CORP 0.00 0 0.00 0 0.00 0
2014 NATL FUEL GAS SUPPLY CORP 0.00 0 0.00 0 0.00 0
2015 NATL FUEL GAS SUPPLY CORP 0.00 0 0.00 0 0.00 0
2016 NATL FUEL GAS SUPPLY CORP 0.00 0 0.00 0 0.00 0
2017 NATL FUEL GAS SUPPLY CORP 0.00 0 0.00 0 0.00 0
2018 NATL FUEL GAS SUPPLY CORP 0.00 0 0.00 0 0.00 0

For data sources see[5]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2019 NATL FUEL GAS SUPPLY CORP Servicing Fluid 100.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW005

For data sources see[6]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1073864 Primary Facility 2001-11-01 Routine/Complete Inspection No Violations Noted
1188574 Primary Facility 2002-11-20 Routine/Complete Inspection No Violations Noted
1292502 Primary Facility 2003-12-04 Routine/Complete Inspection No Violations Noted
1575157 Primary Facility 2006-10-25 Routine/Complete Inspection No Violations Noted
1748552 Primary Facility 2008-11-04 Routine/Complete Inspection No Violations Noted
1838929 Primary Facility 2009-10-22 Routine/Complete Inspection No Violations Noted
1926818 Primary Facility 2010-11-09 Routine/Complete Inspection No Violations Noted
1933289 Primary Facility 2010-12-09 Routine/Complete Inspection No Violations Noted
2024196 Primary Facility 2011-10-26 Routine/Complete Inspection No Violations Noted
2028013 Primary Facility 2011-11-07 Routine/Complete Inspection No Violations Noted
2121716 Primary Facility 2012-11-08 Routine/Complete Inspection No Violations Noted
2126021 Primary Facility 2012-12-18 Routine/Complete Inspection No Violations Noted
2214821 Primary Facility 2013-10-15 Routine/Complete Inspection No Violations Noted
2231850 Primary Facility 2013-11-20 Routine/Complete Inspection No Violations Noted
2323166 Primary Facility 2014-11-19 Routine/Complete Inspection No Violations Noted
2415701 Primary Facility 2015-10-13 Routine/Complete Inspection No Violations Noted
2420129 Primary Facility 2015-10-26 Routine/Complete Inspection No Violations Noted
2521355 Primary Facility 2016-09-19 Routine/Complete Inspection No Violations Noted
2641393 Primary Facility 2017-09-25 Routine/Complete Inspection No Violations Noted
2779570 Primary Facility 2018-09-25 Routine/Complete Inspection No Violations Noted At the time of this inspection the casing pressure was 1782. There is one vent on this well that was tested for venting ( flow rate) with the results being 0.3 inches of H2O that is 255cf(cubic feet) flow rate on this vent using a manometer with a 1/8" plate. No violations were noted at this inspection.
2796327 Primary Facility 2018-10-22 Routine/Complete Inspection No Violations Noted At the time of this inspection the casing pressure was 1964 pounds per square inch. There is two (2) annular vents on this well. Using a Manometer on a 1/8" plate 0.1 inches of H2O/52 cubic feet of combustible gas was measured on vent 1. No violations noted at this inspection.
680854 Primary Facility 1988-11-10 Routine/Complete Inspection No Violations Noted
680855 Primary Facility 1989-11-03 Routine/Complete Inspection No Violations Noted
683274 Primary Facility 1990-11-21 Routine/Complete Inspection No Violations Noted
683958 Primary Facility 1991-11-13 Routine/Complete Inspection No Violations Noted
684603 Primary Facility 1992-11-12 Routine/Complete Inspection No Violations Noted
685339 Primary Facility 1993-11-03 Routine/Complete Inspection No Violations Noted
686195 Primary Facility 1994-11-10 Routine/Complete Inspection No Violations Noted
686999 Primary Facility 1995-11-21 Routine/Complete Inspection No Violations Noted
687915 Primary Facility 1996-11-13 Routine/Complete Inspection No Violations Noted
688650 Primary Facility 1997-11-13 Routine/Complete Inspection No Violations Noted
689570 Primary Facility 1998-11-04 Routine/Complete Inspection No Violations Noted
689772 Primary Facility 1999-06-09 Routine/Complete Inspection No Violations Noted
890754 Primary Facility 1999-10-26 Routine/Complete Inspection No Violations Noted
981162 Primary Facility 2000-11-06 Routine/Complete Inspection No Violations Noted

For data sources see[7]

References