37-105-00443

Well Details

Well ID: 37-105-00443
Loading map...
Country: United States
State: Pennsylvania
County: Potter
Municipality: Eulalia Township
Operator Name:
Well Pad ID:
Farm/Lease Name: PA FOREST WH-5
License Status: ACTIVE
Spud Date:
Permit Date:
Well Type: STORAGE WELL
Unconventional Well: N
Configuration: Vertical Well
Conservation: No
Latitude: 41.507422
Longitude: -77.986112

For data sources see[1][2][3]

Well History

Date Event
1948-09-16 Drilling Completion
2001-01-08 OLD WELL

For data sources see[4]


Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2010 NATL FUEL GAS SUPPLY CORP 0.00 0 0.00 0 0.00 0
2011 NATL FUEL GAS SUPPLY CORP 0.00 0 0.00 0 0.00 0
2012 NATL FUEL GAS SUPPLY CORP 0.00 0 0.00 0 0.00 0
2013 NATL FUEL GAS SUPPLY CORP 0.00 0 0.00 0 0.00 0
2014 NATL FUEL GAS SUPPLY CORP 0.00 0 0.00 0 0.00 0
2015 NATL FUEL GAS SUPPLY CORP 0.00 0 0.00 0 0.00 0
2016 NATL FUEL GAS SUPPLY CORP 0.00 0 0.00 0 0.00 0
2017 NATL FUEL GAS SUPPLY CORP 0.00 0 0.00 0 0.00 0
2018 NATL FUEL GAS SUPPLY CORP 0.00 0 0.00 0 0.00 0

For data sources see[5]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1063772 Primary Facility 2001-09-26 Routine/Complete Inspection No Violations Noted
1175917 Primary Facility 2002-10-08 Routine/Complete Inspection No Violations Noted
1275818 Primary Facility 2003-10-01 Routine/Complete Inspection No Violations Noted
1569882 Primary Facility 2006-09-25 Routine/Complete Inspection No Violations Noted
1659517 Primary Facility 2007-10-09 Routine/Complete Inspection No Violations Noted
1744737 Primary Facility 2008-10-14 Routine/Complete Inspection No Violations Noted
1852037 Primary Facility 2009-11-04 Routine/Complete Inspection No Violations Noted
1925656 Primary Facility 2010-11-03 Routine/Complete Inspection No Violations Noted
2023124 Primary Facility 2011-11-02 Routine/Complete Inspection No Violations Noted
2113285 Primary Facility 2012-10-26 Routine/Complete Inspection No Violations Noted
2227673 Primary Facility 2013-11-12 Routine/Complete Inspection No Violations Noted
2325757 Primary Facility 2014-11-04 Routine/Complete Inspection No Violations Noted
2423095 Primary Facility 2015-11-03 Routine/Complete Inspection No Violations Noted
2525955 Primary Facility 2016-09-27 Routine/Complete Inspection No Violations Noted
2649193 Primary Facility 2017-10-16 Routine/Complete Inspection No Violations Noted
2793541 Primary Facility 2018-10-09 Routine/Complete Inspection No Violations Noted At the time of this inspection the casing pressure was 0 pounds per square inch. There is one (1) annular vent on this well. This well was temporarily shut in at this inspection. No venting was noted at this inspection. No violations noted at this inspection.
680723 Primary Facility 1988-09-27 Routine/Complete Inspection No Violations Noted
680724 Primary Facility 1989-09-26 Routine/Complete Inspection No Violations Noted
683768 Primary Facility 1991-09-25 Routine/Complete Inspection No Violations Noted
684409 Primary Facility 1992-09-29 Routine/Complete Inspection No Violations Noted
685066 Primary Facility 1993-09-28 Routine/Complete Inspection No Violations Noted
685827 Primary Facility 1994-10-04 Routine/Complete Inspection No Violations Noted
685834 Primary Facility 1994-10-04 Routine/Complete Inspection No Violations Noted
686761 Primary Facility 1995-10-02 Routine/Complete Inspection No Violations Noted
687589 Primary Facility 1996-10-07 Routine/Complete Inspection No Violations Noted
688295 Primary Facility 1997-10-02 Routine/Complete Inspection No Violations Noted
689125 Primary Facility 1998-09-29 Routine/Complete Inspection No Violations Noted
838622 Primary Facility 1999-09-29 Routine/Complete Inspection No Violations Noted
972180 Primary Facility 2000-10-02 Routine/Complete Inspection No Violations Noted

For data sources see[6]