37-081-21206

Well Details

Well ID: 37-081-21206
Loading map...
Country: United States
State: Pennsylvania
County: Lycoming
Municipality: Lewis Township
Operator Name: SENECA RESOURCES CO LLC
Well Pad ID: 145506
Farm/Lease Name: DCNR 100 56H 50882
License Status:
Spud Date:
Permit Date: 2013-06-21
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.419136
Longitude: -77.059481

For data sources see[1][2][3]

Well History

Date Event
2013-06-21 New Permit Application
2013-07-05 Performed Spud Operation
2013-09-15 Drilling Completion
2013-12-15 Perforation
2015-01-02 DEVIATED

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2014-01-09 2014-02-11 8,926 7,779,240 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 AL-7NR Trican Corrosion Inhibitor Prop-2-yn-1-ol 107-19-7 1 0.00002319 0
FR-15 Trican Friction Reducer Proprietary Amide Proprietary 2.5 0.00178735 0
Distillates (petroleum), Hydrotreated Light 64742-47-8 25 0.0178735 0
MBC 516 Trican Biocide Glutaraldehyde 111-30-8 27 0.00231891 0
Ethanol 64-17-5 2.8 0.00024048 0
Didecyl dimethyl ammonium chloride 7173-51-5 8.3 0.00071285 0
N-alkyl dimethyl benzyl ammonium chloride 68424-85-1 5.5 0.00047237 0
Proppant 40/70 Ottawa Trican Proppant Crystalline silica (quartz) 14808-60-7 100 5.12333 0
Sl-7 Trican Scale Inhibitor Ethylene glycol 107-21-1 30 0.00755587 0
Gyptron T-390 Champion Technologies Scale Inhibitor Methanol 67-56-1 10 0.00004822 0
Nonylphenol Ethoxylate Proprietary 10 0.00004822 0
FEAC 20 Trican Iron Control Citric acid 77-92-9 30 0.00049255 0
Acetic acid 64-19-7 50 0.00082091 0
Bactron K-219 Champion Technologies Biocide Quaternary Ammonium Compounds,
Benzyl-C12-16-alkidimethyl, Chlorides
68424-85-1 20 0.00026961 0
Methanol 67-56-1 45 0.00060661 0
Glutaraldehyde 111-30-8 75 0.00101102 0
Proppant 30/50 Ottawa Trican Proppant Crystalline silica (quartz) 14808-60-7 100 5.10623 0
FlowPlus DR-5018 Champion Technologies Friction Reducer Acrylamide 79-06-1 0.1 0.00000563 0
Hydrotreated Light Distillates 64742-47-8 30 0.00168827 0
Sorbitan Monoleate 1338-43-8 5 0.00028138 0
7.5% HydroChloric Acid Trican Acid Hydrochloric Acid HCl 7647-01-0 7.5 0.0806607 0
Proppant 80/100 Oklahoma Trican Proppant Silica 14808-60-7 100 0.783408 0
Water Seneca Resources Carrier/Base Fluid Water 7732-18-5 100 88.8701 0

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2013 SENECA RESOURCES CO LLC 0.00 0 0.00 0 0.00 0
2014 SENECA RESOURCES CO LLC 2,297,438.00 203 0.00 0 0.00 0
2015 SENECA RESOURCES CO LLC 1,565,740.09 239 0.00 0 0.00 0
2016 SENECA RESOURCES CO LLC 1,226,304.65 292 0.00 0 0.00 0
2017 SENECA RESOURCES CO LLC 1,184,050.46 365 0.00 0 0.00 0
2018 SENECA RESOURCES CO LLC 797,791.76 364 0.00 0 0.00 0
2019 SENECA RESOURCES CO LLC 580,119.30 324 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2013 SENECA RESOURCES CO LLC Drill Cuttings 1,088.66 Tons RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR097R017
2013 SENECA RESOURCES CO LLC Drill Cuttings 321.16 Tons LANDFILL 301358
2014 SENECA RESOURCES CO LLC Produced Fluid 11.00 Bbl INJECTION DISPOSAL WELL 34-133-20114
2014 SENECA RESOURCES CO LLC Produced Fluid 25.00 Bbl INJECTION DISPOSAL WELL 34-133-24096
2014 SENECA RESOURCES CO LLC Produced Fluid 9,513.00 Bbl REUSE OTHER THAN ROAD SPREADING
2015 SENECA RESOURCES CO LLC Produced Fluid 370.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NW011
2015 SENECA RESOURCES CO LLC Produced Fluid 4.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NW005
2015 SENECA RESOURCES CO LLC Produced Fluid 8.00 Bbl INJECTION DISPOSAL WELL 34-133-20114
2015 SENECA RESOURCES CO LLC Produced Fluid 301.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016 SENECA RESOURCES CO LLC Produced Fluid 66.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2016 SENECA RESOURCES CO LLC Other Oil & Gas Wastes 25.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NW011
2016 SENECA RESOURCES CO LLC Produced Fluid 656.96 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NW011
2017 SENECA RESOURCES CO LLC Produced Fluid 358.25 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2017 SENECA RESOURCES CO LLC Produced Fluid 533.42 Bbl REUSE (AT WELL PAD)
2018 SENECA RESOURCES CO LLC Produced Fluid 351.42 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2018 SENECA RESOURCES CO LLC Other Oil & Gas Wastes 34.28 Bbl REUSE (AT WELL PAD)
2018 SENECA RESOURCES CO LLC Produced Fluid 539.27 Bbl REUSE (AT WELL PAD)
2019 SENECA RESOURCES CO LLC Other Oil & Gas Wastes 43.46 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2019 SENECA RESOURCES CO LLC Other Oil & Gas Wastes 37.00 Bbl RESIDUAL WASTE TRANSFER FACILITY WMGR123NC039
2019 SENECA RESOURCES CO LLC Produced Fluid 77.08 Bbl INJECTION DISPOSAL WELL 34-155-24079
2019 SENECA RESOURCES CO LLC Waste Water Treatment Sludge 29.75 Tons RESIDUAL WASTE PROCESSING FACILITY WMGR123NW005
2019 SENECA RESOURCES CO LLC Synthetic Liner Materials 4.66 Tons LANDFILL 301358
2019 SENECA RESOURCES CO LLC Drilling Fluid Waste 6.03 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123
2019 SENECA RESOURCES CO LLC Other Oil & Gas Wastes 82.15 Bbl REUSE (AT WELL PAD)
2019 SENECA RESOURCES CO LLC Produced Fluid 18.57 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC003
2019 SENECA RESOURCES CO LLC Produced Fluid 34.80 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123
2019 SENECA RESOURCES CO LLC Produced Fluid 515.33 Bbl RESIDUAL WASTE TRANSFER FACILITY WMGR123NC039
2019 SENECA RESOURCES CO LLC Produced Fluid 1,484.25 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2019 SENECA RESOURCES CO LLC Produced Fluid 474.44 Bbl STORAGE PENDING DISPOSAL OR REUSE WMGR123NC038
2019 SENECA RESOURCES CO LLC Produced Fluid 14.29 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW005
2019 SENECA RESOURCES CO LLC Other Oil & Gas Wastes 35.77 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW005
2019 SENECA RESOURCES CO LLC Produced Fluid 875.84 Bbl REUSE (AT WELL PAD)

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2194965 Primary Facility 2013-08-12 Drilling/Alteration No Violations Noted
2240284 Primary Facility 2014-01-27 Drilling/Alteration No Violations Noted
2243273 Primary Facility 2014-01-30 Routine/Partial Inspection No Violations Noted Trican-frac job, under pressure on the 55H, wireline on 60H. No Vio
2252908 Primary Facility 2014-03-10 Routine/Partial Inspection No Violations Noted drilling out plugs, frac crew offsite, containment good, field conductivity good. No Vio.
2288835 Primary Facility 2014-07-22 Routine/Complete Inspection No Violations Noted
2481234 Primary Facility 2016-05-03 Routine/Complete Inspection No Violations Noted
2597114 Primary Facility 2017-05-18 Routine/Complete Inspection No Violations Noted Routine inspection of unconvnetional well in production. No violations noted at time of inspection.
2606615 Primary Facility 2017-06-14 Routine/Complete Inspection No Violations Noted Weather: hot and sunny. Arrived @ 10.40. Seven wells in a liner array. Each well had 3 stainless steel annular ¼”-diameter vent candy canes which were tagged. The 9-5/8” x 5-1/2” vents were shut--in. Within the cellar, this annulus was also plumbed into a 2” flexible hose which appeared to link each of the vents to a 2100-gallon poly tank. Gas meter was not functioning at the time of my inspection. There were no violations at this time. Left location @ 11:10.

55H: 5-1/2” gauge: 649 psi (digital) 56H: 5-1/2” gauge: 561 psi (digital) 57H: 5-1/2” gauge: 488 psi (digital) 58H: 5-1/2” gauge: 477 psi (digital) 59H: 5-1/2” gauge: 471 psi (digital) 60H: 5-1/2” gauge: 401 psi (digital) 112H: 5-1/2” gauge: 516 psi (digital).

2606617 Primary Facility 2017-06-14 Routine/Complete Inspection No Violations Noted
2612579 Primary Facility 2017-07-05 Routine/Complete Inspection No Violations Noted
2814496 Primary Facility 2018-12-13 Routine/Complete Inspection No Violations Noted Weather was 35° and cloudy at time of inspection. Met with Seneca resources representative Rod Mills on location. Well was covered with a steel cage due to drilling operations on location. Well had digital pressure monitoring equipment attached to the production casing and the production tubing. Casing pressure was 338 psi and tubing pressure was 260 psi at time of inspection. There were 3 annulus vent plumbed to surface at time of inspection. 0% combustible gas was detected on the annulus vents at time of inspection. No violations were noted at time of inspection.

For data sources see[8]

References