37-081-20856

Well Details

Well ID: 37-081-20856
Loading map...
Country: United States
State: Pennsylvania
County: Lycoming
Municipality: Lewis Township
Operator Name: SENECA RESOURCES CO LLC
Well Pad ID: 150570
Farm/Lease Name: DCNR 100 8H 50393
License Status:
Spud Date:
Permit Date: 2012-01-31
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.445781
Longitude: -77.010886

For data sources see[1][2][3]

Well History

Date Event
2012-01-31 New Permit Application
2012-02-14 Performed Spud Operation
2012-06-26 Drilling Completion
2012-09-30 Perforation
2014-02-24 DEVIATED

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2012-10-03 2012-10-03 8,722 7,001,946

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Proppant 40/70 Ottawa Universal Well Services Proppant Quartz 14808-60-7 100.00 4.64
Proppant 80/100 Oklahoma Universal Well Services Proppant Quartz 14808-60-7 100.00 1.04
7.5 HydroChloric Acid Universal Well Services Acid Hydrochloric acid 7647-01-0 7.50 0.05
Scale Inhibitor - Gyptron T-390 Champion Technologies Scale Inhibitor Nonylphenol Ethoxylate 10.00 0.00112000
Methanol 67-56-1 10.00 0.00112000
Biocide - Bactron K 139 Champion Technologies Biocide Quaternary ammonium compounds,
benzyl-C12-16-alkyldimethyl, chlorides
68424-85-1 10.00 0.00365000
Ethanol 64-17-5 5.00 0.00182000
Glutaraldehyde 111-30-8 5.00 0.00182000
Proppant 30/50 Ottawa Universal Well Services Proppant Quartz 14808-60-7 100.00 4.41
FlowPlus DR-5018 Champion Technologies Friction Reducer Acrylamide 79-06-1 0.10 0.00010000
Sorbitan, mono-(9Z)-9-octadecenoate 1338-43-8 5.00 0.00491000
Distillates, petroleum, hydrotreated light 64742-47-8 30.00 0.02
Unigel 5F Universal Well Services Guar Gel Dry Add Guar Gum 100.00 0.00115000
Unihib G Universal Well Services Corrosion Inhibitor Resin Based Nonionic Inhibitor 35.00 0.00011000
Ethoxylated Alcohol 35.00 0.00011000
Diethylene glycol monobutyl ether 112-34-5 50.00 0.00015000
Iron Stabilizer II Universal Well Services Corrosion Inhibitor Ethylene glycol 107-21-1 30.00 0.00036000
GB L Universal Well Services Breaker Ethylene glycol 107-21-1 60.00 0.00003000

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2011 SENECA RESOURCES CO LLC 0.00 0 0.00 0 0.00 0
2012 SENECA RESOURCES CO LLC 0.00 0 0.00 0 0.00 0
2013 SENECA RESOURCES CO LLC 2,226,189.00 334 0.00 0 0.00 0
2014 SENECA RESOURCES CO LLC 1,263,705.70 355 0.00 0 0.00 0
2015 SENECA RESOURCES CO LLC 191,026.70 66 0.00 0 0.00 0
2016 SENECA RESOURCES CO LLC 1,123,207.19 336 0.00 0 0.00 0
2017 SENECA RESOURCES CO LLC 734,777.75 362 0.00 0 0.00 0
2018 SENECA RESOURCES CO LLC 568,249.87 364 0.00 0 0.00 0
2019 SENECA RESOURCES CO LLC 475,112.09 365 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2012 SENECA RESOURCES CO LLC Fracturing Fluid Waste 0.46 Tons LANDFILL 301358
2012 SENECA RESOURCES CO LLC Drill Cuttings 1,370.38 Tons LANDFILL 301358
2013 SENECA RESOURCES CO LLC Produced Fluid 12,476.00 Bbl REUSE OTHER THAN ROAD SPREADING
2013 SENECA RESOURCES CO LLC Produced Fluid 32.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NC012
2013 SENECA RESOURCES CO LLC Produced Fluid 255.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC012
2014 SENECA RESOURCES CO LLC Produced Fluid 16.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC012
2014 SENECA RESOURCES CO LLC Produced Fluid 35.00 Bbl INJECTION DISPOSAL WELL 34-133-20114
2014 SENECA RESOURCES CO LLC Produced Fluid 2,739.00 Bbl REUSE OTHER THAN ROAD SPREADING
2015 SENECA RESOURCES CO LLC Produced Fluid 1,604.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NW011
2015 SENECA RESOURCES CO LLC Produced Fluid 49.00 Bbl INJECTION DISPOSAL WELL 34-133-20114
2015 SENECA RESOURCES CO LLC Produced Fluid 777.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016 SENECA RESOURCES CO LLC Produced Fluid 84.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016 SENECA RESOURCES CO LLC Produced Fluid 127.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2016 SENECA RESOURCES CO LLC Produced Fluid 1,639.20 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NW011
2017 SENECA RESOURCES CO LLC Produced Fluid 867.32 Bbl REUSE (AT WELL PAD)
2017 SENECA RESOURCES CO LLC Produced Fluid 631.96 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2018 SENECA RESOURCES CO LLC Produced Fluid 641.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2018 SENECA RESOURCES CO LLC Other Oil & Gas Wastes 129.28 Bbl REUSE (AT WELL PAD)
2018 SENECA RESOURCES CO LLC Produced Fluid 730.16 Bbl REUSE (AT WELL PAD)
2018 SENECA RESOURCES CO LLC Other Oil & Gas Wastes 222.14 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2018 SENECA RESOURCES CO LLC Synthetic Liner Materials 0.10 Tons LANDFILL 301358
2019 SENECA RESOURCES CO LLC Other Oil & Gas Wastes 147.64 Bbl RESIDUAL WASTE TRANSFER FACILITY WMGR123NC039
2019 SENECA RESOURCES CO LLC Produced Fluid 96.67 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW005
2019 SENECA RESOURCES CO LLC Produced Fluid 25.55 Bbl INJECTION DISPOSAL WELL 34-155-24079
2019 SENECA RESOURCES CO LLC Synthetic Liner Materials 6.38 Tons LANDFILL 301358
2019 SENECA RESOURCES CO LLC Produced Fluid 780.74 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2019 SENECA RESOURCES CO LLC Other Oil & Gas Wastes 75.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2019 SENECA RESOURCES CO LLC Other Oil & Gas Wastes 373.75 Bbl REUSE (AT WELL PAD)
2019 SENECA RESOURCES CO LLC Produced Fluid 272.54 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC003
2019 SENECA RESOURCES CO LLC Produced Fluid 251.11 Bbl RESIDUAL WASTE TRANSFER FACILITY WMGR123NC039
2019 SENECA RESOURCES CO LLC Waste Water Treatment Sludge 9.16 Tons RESIDUAL WASTE PROCESSING FACILITY WMGR123NW005
2019 SENECA RESOURCES CO LLC Other Oil & Gas Wastes 76.98 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW005
2019 SENECA RESOURCES CO LLC Other Oil & Gas Wastes 30.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC003
2019 SENECA RESOURCES CO LLC Produced Fluid 587.83 Bbl REUSE (AT WELL PAD)

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2061068 Primary Facility 2012-04-11 Routine/Complete Inspection No Violations Noted Rig on the M-pad drilling the 7H top-hole section, getting ready to switch to mud and go back through
2061586 Primary Facility 2012-04-20 Drilling/Alteration No Violations Noted
2089807 Primary Facility 2012-08-06 Drilling/Alteration No Violations Noted
2098574 Primary Facility 2012-09-06 Routine/Complete Inspection No Violations Noted
2105922 Primary Facility 2012-10-04 Routine/Partial Inspection No Violations Noted
2128885 Primary Facility 2013-01-09 Routine/Complete Inspection No Violations Noted
2150539 Primary Facility 2013-03-22 Routine/Complete Inspection No Violations Noted
2173418 Primary Facility 2013-05-31 Routine/Complete Inspection No Violations Noted
2487625 Primary Facility 2016-05-17 Routine/Complete Inspection No Violations Noted Routine Inspection; 5/17/2016.

I entered the DCNR Tract 100 M pad at 09:17 and began the inspection. At the time of the inspection, the DCNR 100 3H (081-20853), 5H (081-20268), 6H (081-20854), 7H (081-20855), 8H (081-20856), 9H (081-20857), and 66H (081-20975) wells were in production.

The well site has been expanded so that the impoundment area originally permitted in the ESCGP has been reclaimed and replaced with impervious well pad area. The site has not been restored according to the PCSM (Post Construction Stormwater Management) plan in the ESCGP which does not include the expanded well pad area. Well cellars have been constructed on the expanded well pad area but each of the wells that were permitted for this expanded pad area is classified as “Operator Reported Not Drilled.” The current ESCGP expired on 1/10/2015. The restoration assessment spreadsheet indicates the Notice of Termination and Well Site Restoration Report as pending and a return trip is planned. The most recent well permits iss

2487626 Primary Facility 2016-05-17 Routine/Complete Inspection No Violations Noted Routine Inspection; 5/17/2016.

I entered the DCNR Tract 100 M pad at 09:17 and began the inspection. At the time of the inspection, the DCNR 100 3H (081-20853), 5H (081-20268), 6H (081-20854), 7H (081-20855), 8H (081-20856), 9H (081-20857), and 66H (081-20975) wells were in production.

The well site has been expanded so that the impoundment area originally permitted in the ESCGP has been reclaimed and replaced with impervious well pad area. The site has not been restored according to the PCSM (Post Construction Stormwater Management) plan in the ESCGP which does not include the expanded well pad area. Well cellars have been constructed on the expanded well pad area but each of the wells that were permitted for this expanded pad area is classified as “Operator Reported Not Drilled.” The current ESCGP expired on 1/10/2015. The restoration assessment spreadsheet indicates the Notice of Termination and Well Site Restoration Report as pending and a return trip is planned. The most recent well permits iss

2603509 Primary Facility 2017-06-12 Routine/Complete Inspection No Violations Noted Routine inspection of unconventional well in production. No violations noted at time of inspection.
2800561 Primary Facility 2018-11-08 Routine/Complete Inspection No Violations Noted Weather was 39° and sunny at time of inspection. There were no Seneca Resources representatives on location at time of inspection. Well had digital pressure monitoring equipment on the production tubing and the production casing. Tubing pressure was 163 psi and casing pressure was 260 psi at time of inspection. Well had 3 annulus vent plumbed to surface that we labeled clearly. 0% combustible gas was detected on the annulus vents at time of inspection. No violations were noted at time of inspection.
2805165 Primary Facility 2018-11-20 Routine/Complete Inspection No Violations Noted Seven wells staged for production phase. Seven each water separators. No leaks detected from production equipment. Methanol tank located near well heads. No violations noted.

For data sources see[8]

References