X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-081-20377

Well Details

Well ID: 37-081-20377
Loading map...
Country: United States
State: Pennsylvania
County: Lycoming
Municipality: Penn Township
Operator Name: EXCO RESOURCES PA LLC
Well Pad ID: 148667
Farm/Lease Name: KENSINGER UNIT 7H
License Status:
Spud Date:
Permit Date: 2010-10-15
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.262072
Longitude: -76.618925

For data sources see[1][2][3]

Well History

Date Event
2010-10-15 New Permit Application
2011-05-24 Performed Spud Operation
2011-07-07 New Permit Application
2011-09-27 New Permit Application
2011-10-15 Drilling Completion
2012-03-13 Perforation
2012-09-28 DEVIATED

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2012-03-13 2012-03-13 6,775 4,498,525

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Water Base Fluid Water 100.00 85.48
DWP-944 Calfrac Well Services Biocide 2,2-Dibromo-3-nitrilopropionamide 10222-01-2 40.00 0.01
Polyethylene glycol 25322-68-3 70.00 0.02
DAP-923 Calfrac Well Services Acid Corrosion Inhibitor Olefin 5.00 0.00006000
Propargyl Alcohol 10.00 0.00012000
Methanol 67-56-1 60.00 0.00073000
Thiourea polymer 68527-49-1 30.00 0.00036000
Fatty Acids 30.00 0.00036000
Polyoxyalkylenes 30.00 0.00036000
DWP-612 Calfrac Well Services Friction Reducer No Hazardous Materials 100.00 0.07
Hydrochloric Acid Calfrac Well Services Acid Hydrochloric acid 7647-01-0 35.00 0.24
Sand (Proppant) Calfrac Well Services Propping Agent Quartz 14808-60-7 100.00 13.68
DAP-901 Calfrac Well Services Scale Inhibitor Amine salt 5.00 0.00095000
Ammonium chloride 12125-02-9 10.00 0.00190000
Methanol 67-56-1 30.00 0.00571000
Organic phosphonate 30.00 0.00571000
Phosphoric Acid ammonium salt 5.00 0.00095000
Oxyalkylated polyamine 5.00 0.00095000

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2010 CHIEF OIL & GAS LLC 0.00 0 0.00 0 0.00 0
2011 EXCO RESOURCES PA LLC 0.00 0 0.00 0 0.00 0
2012 EXCO RESOURCES PA LLC 345,008.00 205 0.00 0 0.00 0
2013 EXCO RESOURCES PA LLC 940,727.00 365 0.00 0 0.00 0
2014 EXCO RESOURCES PA LLC 754,796.00 365 0.00 0 0.00 0
2015 EXCO RESOURCES PA LLC 539,736.00 349 0.00 0 0.00 0
2016 EXCO RESOURCES PA LLC 334,940.00 278 0.00 0 0.00 0
2017 EXCO RESOURCES PA LLC 361,509.00 337 0.00 0 0.00 0
2018 EXCO RESOURCES PA LLC 322,808.00 364 0.00 0 0.00 0
2019 EXCO RESOURCES PA LLC 273,023.00 364 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2011 EXCO RESOURCES PA LLC Drilling Fluid Waste 577.64 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0101508
2012 EXCO RESOURCES PA LLC Produced Fluid 2,104.46 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR119
2012 EXCO RESOURCES PA LLC Produced Fluid 547.60 Bbl REUSE OTHER THAN ROAD SPREADING
2012 EXCO RESOURCES PA LLC Fracturing Fluid Waste 0.04 Tons LANDFILL 301358
2012 EXCO RESOURCES PA LLC Drill Cuttings 8.67 Tons LANDFILL 301358
2012 EXCO RESOURCES PA LLC Fracing Fluid Waste 300.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR119
2012 EXCO RESOURCES PA LLC Fracing Fluid Waste 1,752.00 Bbl STORAGE PENDING DISPOSAL OR REUSE
2013 EXCO RESOURCES PA LLC Produced Fluid 109.52 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC009
2013 EXCO RESOURCES PA LLC Produced Fluid 219.04 Bbl STORAGE PENDING DISPOSAL OR REUSE
2013 EXCO RESOURCES PA LLC Fracturing Fluid Waste 3.96 Tons LANDFILL 301358
2013 EXCO RESOURCES PA LLC Drill Cuttings 1.19 Tons LANDFILL 301358
2013 EXCO RESOURCES PA LLC Produced Fluid 493.32 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR119
2013 EXCO RESOURCES PA LLC Produced Fluid 109.50 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR119
2014 EXCO RESOURCES PA LLC Produced Fluid 110.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR119
2014 EXCO RESOURCES PA LLC Produced Fluid 109.50 Bbl INJECTION DISPOSAL WELL PAS2D205BCLE
2014 EXCO RESOURCES PA LLC Produced Fluid 110.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW018
2014 EXCO RESOURCES PA LLC Produced Fluid 109.50 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC010
2015 EXCO RESOURCES PA LLC Produced Fluid 220.00 Bbl INJECTION DISPOSAL WELL PAS2D205BCLE
2016 EXCO RESOURCES PA LLC Produced Fluid 110.00 Bbl INJECTION DISPOSAL WELL PAS2D205BCLE
2017 EXCO RESOURCES PA LLC Produced Fluid 100.00 Bbl INJECTION DISPOSAL WELL PAS2D205BCLE
2018 EXCO RESOURCES PA LLC Produced Fluid 200.00 Bbl INJECTION DISPOSAL WELL PAS2D205BCLE
2019 EXCO RESOURCES PA LLC Produced Fluid 31.60 Bbl REUSE (AT WELL PAD)
2019 EXCO RESOURCES PA LLC Produced Fluid 83.00 Bbl INJECTION DISPOSAL WELL PAS2D205BCLE

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1987894 Primary Facility 2011-07-14 Drilling/Alteration No Violations Noted
2010389 Primary Facility 2011-10-13 Drilling/Alteration No Violations Noted
2021429 Primary Facility 2011-11-22 Drilling/Alteration No Violations Noted
2022428 Primary Facility 2011-11-29 Routine/Complete Inspection No Violations Noted
2030558 Primary Facility 2011-12-29 Routine/Complete Inspection No Violations Noted
2034689 Primary Facility 2012-01-12 Routine/Complete Inspection No Violations Noted
2056710 Primary Facility 2012-04-02 Routine/Partial Inspection No Violations Noted
2056872 Primary Facility 2012-04-05 Routine/Complete Inspection No Violations Noted
2065776 Primary Facility 2012-05-07 Routine/Complete Inspection No Violations Noted
2072716 Primary Facility 2012-06-01 Drilling/Alteration No Violations Noted
2076750 Primary Facility 2012-06-12 Routine/Complete Inspection No Violations Noted
2077316 Primary Facility 2012-06-14 Routine/Complete Inspection No Violations Noted
2081819 Primary Facility 2012-07-06 Incident- Response to Accident or Event No Violations Noted
2092483 Primary Facility 2012-08-15 Routine/Complete Inspection No Violations Noted
2094156 Primary Facility 2012-08-23 Routine/Partial Inspection No Violations Noted
2104855 Primary Facility 2012-09-27 Routine/Complete Inspection No Violations Noted
2148024 Primary Facility 2013-03-12 Routine/Complete Inspection No Violations Noted
2433755 Primary Facility 2015-12-14 Routine/Complete Inspection No Violations Noted Kensinger 7H
2478322 Primary Facility 2016-04-19 Routine/Complete Inspection No Violations Noted At the time of the inspection, the Kensinger Unit 3H (081-20255), 6H (081-20388), 7H (08-20377), 8H (081-20378), 9H (081-20379), 10H (081-20380), and 11H (081-20381) wells were all in production. The well site remains at its original size and has not been restored. The Well Site Compliance Information Request reply (submitted 9/21/2015) states the well pad was reclaimed and the NOT will be submitted in 9/2015. The Department has no record of an ESCGP issued for the site and no well permits have been issued for the site since 2010. According to the Department’s records, the wells onsite were drilled in 2010 and 2011 and completed in 2010 and 2012. The well pad remains at its original size although aerial photos indicate a pit was located onsite that has since been closed. I recommend you apply for an ESCGP-2 to cover this since it has not been restored and is part of a larger disturbance.
2550507 Primary Facility 2017-01-05 Routine/Complete Inspection No Violations Noted Arrived @ 13:10. Weather: cloudy, cold. All 7 wells were in production. No company personnel on site. Annuli were monitored for combustible gas (Altair 5X gas meter, calibrated 01/05/17). Digital top gauge pressures.

Kensinger 3H, Gravel-filled cellar, no combustible gas detected, top gauge: 417 psi. Kensinger 6H, Gravel-filled cellar, no combustible gas detected, top gauge: 324 psi. Kensinger 7H, Gravel-filled cellar, no combustible gas detected, top gauge: 404 psi. Kensinger 8H, Gravel-filled cellar, no combustible gas detected, top gauge: 328 psi. Kensinger 9H, Gravel-filled cellar, no combustible gas detected, 9-5/8” x 5-1/2” annulus plumbed to dump tank, top gauge: 285 psi.

Kensinger 10H, Gravel-filled cellar 9-5/8” x 5-1/2” annulus: 6% combustible gas/volume, top gauge: 394 psi. Kensinger 11H, Gravel-filled cellar, 9-5/8” x 5-1/2” annulus: 6% combustible gas/volume, top gauge: 445 psi. Left location @ 14:20.

2563544 Primary Facility 2017-02-15 Routine/Complete Inspection No Violations Noted Routine Inspection; 2/15/2017.

The inspection was prompted when Bird Smith called on 2/13/2017 to report a produced water leak. According to the call, approximately 12 barrels of produced water leaked from the Kensinger Unit 3H (081-20255) production tank into containment due to a frozen pipe. Ice was covering the bottom of the containment at the time of the release. At the time of the inspection, seven wells (081-20255, 081-20388, 081-20377, 081-20378, 081-20379, 081-20380, 081-20381) were in production. Field conductivity was 1,500 umhos/cm in containment on top of the ice just under the leak. Under the ice, the water was 120 umhos/cm. The area around the containment was frozen with snow but no evidence was found to suggest produced water left containment. On 12/21/2016, the Department issued an ESCGP for this site for the first time. I recommend implementing the PCSM/restoration plans for the site as soon as possible. No Violations Noted.

2799190 Primary Facility 2018-11-06 Routine/Complete Inspection No Violations Noted Seven wells staged for production phase. Seven each water separators. No leaks detected from production equipment. No violations noted.

For data sources see[8]

References