If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-081-20140 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.268908,"lon":-77.298031,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Lycoming | |
Municipality: Watson Township | |
Operator Name: EXCO RESOURCES PA LLC | |
Well Pad ID: 147316 | |
Farm/Lease Name: ZINCK UNIT 1H | |
License Status: | |
Spud Date: | |
Permit Date: 2009-01-09 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: No | |
Latitude: 41.268908 | |
Longitude: -77.298031 |
Date | Event |
---|---|
2009-01-09 | New Permit Application |
2009-07-19 | Performed Spud Operation |
2009-09-02 | Drilling Completion |
2009-11-23 | DEVIATED |
2010-03-10 | Perforation |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2009 | CHIEF OIL & GAS LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2010 | CHIEF OIL & GAS LLC | 645,045.50 | 226 | 0.00 | 0 | 0.00 | 0 |
2011 | EXCO RESOURCES PA LLC | 474,953.00 | 305 | 0.00 | 0 | 0.00 | 0 |
2012 | EXCO RESOURCES PA LLC | 460,828.00 | 366 | 0.00 | 0 | 0.00 | 0 |
2013 | EXCO RESOURCES PA LLC | 350,534.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2014 | EXCO RESOURCES PA LLC | 287,282.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2015 | EXCO RESOURCES PA LLC | 219,853.00 | 344 | 0.00 | 0 | 0.00 | 0 |
2016 | EXCO RESOURCES PA LLC | 198,305.00 | 262 | 0.00 | 0 | 0.00 | 0 |
2017 | EXCO RESOURCES PA LLC | 205,106.00 | 338 | 0.00 | 0 | 0.00 | 0 |
2018 | EXCO RESOURCES PA LLC | 183,904.00 | 364 | 0.00 | 0 | 0.00 | 0 |
2019 | EXCO RESOURCES PA LLC | 179,710.00 | 364 | 0.00 | 0 | 0.00 | 0 |
For data sources see[5]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2009 | CHIEF OIL & GAS LLC | Drilling | 745.00 Bbl | Brine or Industrial Waste Treatment Plt | PA0008451 |
2010 | CHIEF OIL & GAS LLC | Produced Fluid | 881.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR119 |
2010 | CHIEF OIL & GAS LLC | Produced Fluid | 1,871.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123SW018 |
2010 | CHIEF OIL & GAS LLC | Produced Fluid | 1,792.00 Bbl | INJECTION DISPOSAL WELL | 34-155-21893 |
2010 | CHIEF OIL & GAS LLC | Fracing Fluid Waste | 925.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0008451 |
2010 | CHIEF OIL & GAS LLC | Produced Fluid | 1,112.00 Bbl | INJECTION DISPOSAL WELL | 34-155-23795 |
2010 | CHIEF OIL & GAS LLC | Produced Fluid | 129.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0008451 |
2011 | CHIEF OIL & GAS LLC | Produced Fluid | 1,551.15 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR119 |
2011 | EXCO RESOURCES PA LLC | Produced Fluid | 308.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2011 | EXCO RESOURCES PA LLC | Produced Fluid | 119.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PAS2D205BCLE |
2011 | EXCO RESOURCES PA LLC | Produced Fluid | 249.00 Bbl | STORAGE PENDING DISPOSAL OR REUSE | |
2011 | EXCO RESOURCES PA LLC | Produced Fluid | 238.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0008451 |
2012 | EXCO RESOURCES PA LLC | Produced Fluid | 1,578.55 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR119 |
2013 | EXCO RESOURCES PA LLC | Produced Fluid | 280.90 Bbl | STORAGE PENDING DISPOSAL OR REUSE | |
2013 | EXCO RESOURCES PA LLC | Produced Fluid | 657.12 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR119 |
2013 | EXCO RESOURCES PA LLC | Produced Fluid | 242.80 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR119 |
2013 | EXCO RESOURCES PA LLC | Produced Fluid | 54.76 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC009 |
2014 | EXCO RESOURCES PA LLC | Produced Fluid | 279.50 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR119 |
2014 | EXCO RESOURCES PA LLC | Produced Fluid | 55.00 Bbl | STORAGE PENDING DISPOSAL OR REUSE | |
2014 | EXCO RESOURCES PA LLC | Produced Fluid | 109.60 Bbl | INJECTION DISPOSAL WELL | PAS2D205BCLE |
2014 | EXCO RESOURCES PA LLC | Produced Fluid | 109.60 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC024 |
2014 | EXCO RESOURCES PA LLC | Produced Fluid | 250.10 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC010 |
2014 | EXCO RESOURCES PA LLC | Produced Fluid | 55.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123 |
2015 | EXCO RESOURCES PA LLC | Produced Fluid | 463.10 Bbl | INJECTION DISPOSAL WELL | PAS2D205BCLE |
2015 | EXCO RESOURCES PA LLC | Produced Fluid | 71.40 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016 | EXCO RESOURCES PA LLC | Produced Fluid | 420.00 Bbl | INJECTION DISPOSAL WELL | PAS2D205BCLE |
2017 | EXCO RESOURCES PA LLC | Produced Fluid | 320.00 Bbl | INJECTION DISPOSAL WELL | PAS2D205BCLE |
2017 | EXCO RESOURCES PA LLC | Produced Fluid | 85.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2018 | EXCO RESOURCES PA LLC | Produced Fluid | 596.20 Bbl | INJECTION DISPOSAL WELL | PAS2D205BCLE |
2018 | EXCO RESOURCES PA LLC | Produced Fluid | 84.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC010 |
2019 | EXCO RESOURCES PA LLC | Produced Fluid | 343.00 Bbl | INJECTION DISPOSAL WELL | PAS2D205BCLE |
2019 | EXCO RESOURCES PA LLC | Produced Fluid | 70.00 Bbl | REUSE (AT WELL PAD) |
For data sources see[6]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
1818992 | Primary Facility | 2009-07-27 | Drilling/Alteration | No Violations Noted | |
1824534 | Primary Facility | 2009-08-27 | Drilling/Alteration | No Violations Noted | Union Rig 58 drilling, bottom hole at 10,070' during inspection. |
1826866 | Primary Facility | 2009-09-09 | Routine/Complete Inspection | No Violations Noted | Well has been drilled and the rig recently moved off-site. |
1832311 | Primary Facility | 2009-09-22 | Routine/Complete Inspection | No Violations Noted | |
1858243 | Primary Facility | 2010-01-22 | Routine/Partial Inspection | Violation(s) Noted | |
1867197 | Primary Facility | 2010-03-03 | Routine/Complete Inspection | No Violations Noted | |
1869329 | Primary Facility | 2010-03-12 | Routine/Complete Inspection | No Violations Noted | |
1870604 | Primary Facility | 2010-03-18 | Follow-up Inspection | No Violations Noted | |
1955323 | Primary Facility | 2010-03-16 | Drilling/Alteration | No Violations Noted | Cover insp not input timely. |
1967017 | Primary Facility | 2011-04-20 | Routine/Complete Inspection | No Violations Noted | |
2023199 | Primary Facility | 2011-12-01 | Routine/Complete Inspection | No Violations Noted | |
2796872 | Primary Facility | 2018-10-26 | Routine/Complete Inspection | No Violations Noted | On October 26, 2018, Department representative Brad Kline conducted a routine site inspection at EXCO Resources Zinck Unit 1H pad. No E&S issues were observed during the time of inspection. The site is stable and well vegetated meeting the 70% uniform, perennial, vegetative cover.
There are a total of 1 producing well located on this well pad. The well was tagged with API/well permit number. There is 1 GPU and 1 steel vertical production fluids tank onsite. Both GPU and production fluid tank were stationed in secondary containment. At the time of inspection, the operator was siphoning water out of the production fluid tank secondary containment. The water was being discharged onto the pad. This activity is not in accordance with 78a.60(b)(5). The Department recommends the operator submit a freshwater discharge plan with the appropriate water analysis completed. The discharge water should be spread over a well vegetated area capable of absorbing the water and filtering the solids. |
Inspection ID | Violation ID | Violation Date | Date Resolved | Violation Code | Violation Type | Violation Comments |
---|---|---|---|---|---|---|
1858243 | 579978 | 01/22/2010 | 2010-01-22 | 78.56FRBRD - Failure to maintain 2' freeboard in an impoundment | Administrative | See Insp ID 1867197 done 3/3/10, past viols closed. |
1858243 | 579979 | 01/22/2010 | 2010-01-22 | 102.4 - Failure to minimize accelerated erosion, implement E&S plan, maintain E&S controls. Failure to stabilize site until total site restoration under OGA Sec 206(c)(d) | Environmental Health & Safety | See Insp ID 1867197 done 3/3/10, past viols closed. 102.22 failure to provide permanent stabilization |
Violation ID | Penalty ID | Penalty Code | Penalty Status | Penalty Date | Enforcement Date | Penalty Amount | Amount Collected |
---|---|---|---|---|---|---|---|
579978 | 254446 | NOV - Notice of Violation | Comply/Closed | 2010-03-03 | |||
579979 | 254446 | NOV - Notice of Violation | Comply/Closed | 2010-03-03 |
For data sources see[7]