X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-065-23621

Well Details

Well ID: 37-065-23621
Loading map...
Country: United States
State: Pennsylvania
County: Jefferson
Municipality: Oliver Township
Operator Name: ALLIANCE PETRO CO LLC
Well Pad ID:
Farm/Lease Name: LARRY BURKETT 1
License Status: ACTIVE
Spud Date: 1992-12-30
Permit Date: 1992-11-19
Well Type: GAS
Unconventional Well: N
Configuration: Vertical Well
Conservation: No
Latitude: 41.003829
Longitude: -79.061325

For data sources see[1][2][3]

Well History

Date Event
1992-11-19 New Permit Application
1992-12-30 Performed Spud Operation
1993-01-01 NEWLY DRILLED
1993-01-20 Drilling Completion

For data sources see[4]


Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
1996 DANNIC ENERGY CORP 1719 365 0.00 0 0.00 0
1997 DANNIC ENERGY CORP 1568 365 0.00 0 0.00 0
1998 DANNIC ENERGY CORP 1382 365 0.00 0 0.00 0
1999 DANNIC ENERGY CORP 1181 365 0.00 0 0.00 0
2000 DANNIC ENERGY CORP 890 365 0.00 0 0.00 0
2001 DANNIC ENERGY CORP 793 365 0.00 0 0.00 0
2003 DANNIC ENERGY CORP 646 365 0.00 0 0.00 0
2004 DANNIC ENERGY CORP 621.00 337 0.00 0 0.00 0
2005 EXCO RESOURCES PA INC 0.00 0 0.00 0 0.00 0
2006 EXCO RESOURCES PA INC 0.00 0 0.00 0 0.00 0
2007 DANNIC ENERGY CORP 630 307 0.00 0 0.00 0
2008 DANNIC ENERGY CORP 0.00 0 0.00 0 0.00 0
2009 DANNIC ENERGY CORP 0.00 0 0.00 0 0.00 0
2010 DANNIC ENERGY CORP 0.00 0 0.00 0 0.00 0
2011 DANNIC ENERGY CORP 0.00 0 0.00 0 0.00 0
2012 EXCO RESOURCES PA LLC 1,208.00 366 0.00 0 0.00 0
2013 EXCO RESOURCES PA LLC 323.00 213 0.00 0 0.00 0
2014 EXCO RESOURCES PA LLC 376.00 273 0.00 0 0.00 0
2015 EXCO RESOURCES PA LLC 126.00 92 0.00 0 0.00 0
2016 ALLIANCE PETRO CO LLC 100.00 183 0.00 0 0.00 0
2017 ALLIANCE PETRO CO LLC 146.00 365 0.00 0 0.00 0
2018 ALLIANCE PETRO CO LLC 301.00 365 0.00 0 0.00 0
2019 ALLIANCE PETRO CO LLC 666.00 303 0.00 0 0.00 0

For data sources see[5]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
1996 DANNIC ENERGY CORP Brine 180.00 Bbl Brine or Industrial Waste Treatment Plt PA0028207
1997 DANNIC ENERGY CORP Brine 260.00 Bbl Brine or Industrial Waste Treatment Plt PA0028207
1998 DANNIC ENERGY CORP Brine 160.00 Bbl Brine or Industrial Waste Treatment Plt PA0028207
1999 DANNIC ENERGY CORP Brine 160.00 Bbl Brine or Industrial Waste Treatment Plt PA0028207
2000 DANNIC ENERGY CORP Brine 175.00 Bbl Municipal Sewage Treatment Plant
2001 DANNIC ENERGY CORP Brine 95.00 Bbl Brine or Industrial Waste Treatment Plt PA0028207
2004 DANNIC ENERGY CORP Brine 75.00 Bbl Brine or Industrial Waste Treatment Plt PA0101508
2008 EXCO RESOURCES PA INC Brine 160.00 Bbl Brine or Industrial Waste Treatment Plt PA0095443
2009 EXCO RESOURCES PA INC Brine 164.00 Bbl Other
2012 EXCO RESOURCES PA LLC Produced Fluid 80.00 Bbl PUBLIC SEWAGE TREATMENT PLANT PA0028207
2015 EXCO RESOURCES PA LLC Produced Fluid 60.00 Bbl PUBLIC SEWAGE TREATMENT PLANT PA0028207
2019 ALLIANCE PETRO CO LLC Produced Fluid 45.00 Bbl CENT WASTE TRT FAC NPDES DISCHARGE PA0095273

For data sources see[6]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2640876 Primary Facility 2017-09-28 Routine/Partial Inspection No Violations Noted Well is connected to the sales line with valves open producing on a 31 day chart. Well is also producing house gas. Two patches on the well. One is on the tubing just below the valve, and the other is on the elbow on the flowline. I was notified by Nick Armstrong on September 27 at approximately 4 PM of a release at the well site due to a hole in the tubing when the well tender was flowing the well, approximately one barrel was release to the ground.

Contact me to let me know when a rig will be moved in to change out the top joint of the tubing, and when the flowline will be repaired. The release will also be forwarded to the WQS for follow up.

2641674 Primary Facility 2017-09-29 Incident- Response to Accident or Event Violation(s) Noted This well was drilled in an agricultural area off of Reitz Road in December 1992/January 1993. A spill was reported to the Department from this site on 9/27/2017. Since the volume of the spill is suspected to be less than one barrel, a visual cleanup of the site should be conducted. The violations can be closed when the cleanup is completed and the contaminated soil that is removed has been replaced.
2702289 Primary Facility 2018-03-07 Follow-up Inspection Outstanding Violations - Viols Req'd This well was drilled in an agricultural area off of Reitz Road in December 1992/January 1993. A spill was reported to the Department from this site on 9/27/2017. Since the volume of the spill was determined to be less than one barrel, a visual cleanup of the site was appropriate. Contaminated soil has been removed from the site, and all requested paperwork has been received. The violations can be closed when fill is used to replace the contaminated soil that was removed.
2739728 Primary Facility 2018-06-11 Compliance Evaluation No Violations Noted This well was drilled in an agricultural area off of Reitz Road in December 1992/January 1993. A spill was reported to the Department from this site on 9/27/2017. Since the volume of the spill was determined to be less than one barrel, a visual cleanup of the site was appropriate. Contaminated soil has been removed from the site, and all requested paperwork has been received. Since the most recent inspection on 3/7/2018, the soil that was removed due to contamination has been replaced with clean soil, and vegetation has become established on the surface. All remaining violations have been closed.
563354 Primary Facility 1993-04-06 Routine/Complete Inspection No Violations Noted
563356 Primary Facility 1993-04-22 Routine/Complete Inspection No Violations Noted
563832 Primary Facility 1993-06-04 Routine/Complete Inspection No Violations Noted
563833 Primary Facility 1993-06-03 Routine/Complete Inspection No Violations Noted

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
2641674 798436 2017-09-29 2018-06-11 SWMA 301 Environmental Health & Safety Residual waste was processed in a manner that is inconsistent with rules and regulations of the Department.
2641674 798437 2017-09-29 2018-06-11 CSL 402(b) Environmental Health & Safety Produced fluids were allowed to contact the ground, contrary to the rules and regulations of the Department.
2641674 798438 2017-09-29 2018-06-11 78.57(a) Environmental Health & Safety Produced fluids were discharged to the ground.
2702289 810401 2018-03-07 2018-06-11 SWMA 301 Environmental Health & Safety Residual waste was processed in a manner that is inconsistent with rules and regulations of the Department.
2702289 810402 2018-03-07 2018-06-11 CSL 402(b) Environmental Health & Safety Produced fluids were allowed to contact the ground, contrary to the rules and regulations of the Department.
2702289 810403 2018-03-07 2018-06-11 78.57(a) Environmental Health & Safety Produced fluids were discharged to the ground.

Penalties Applied

Violation ID Penalty ID Penalty Code Penalty Status Penalty Date Enforcement Date Penalty Amount Amount Collected
798436 361980 NOV - Notice of Violation 2018-06-11
798437 361980 NOV - Notice of Violation 2018-06-11
798438 361980 NOV - Notice of Violation 2018-06-11
810401 361980 NOV - Notice of Violation 2018-06-11
810402 361980 NOV - Notice of Violation 2018-06-11
810403 361980 NOV - Notice of Violation 2018-06-11

For data sources see[7]

References