37-063-37496

Well Details

Well ID: 37-063-37496
Loading map...
Country: United States
State: Pennsylvania
County: Indiana
Municipality: Center Township
Operator Name: XTO ENERGY INC
Well Pad ID: 145688
Farm/Lease Name: FABIN UNIT A3H
License Status: INACTIVE
Spud Date: 2013-09-24
Permit Date: 2013-06-24
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 40.562025
Longitude: -79.256297

For data sources see[1][2][3]

Well History

Date Event
2010-10-31 Drilling Completion
2013-06-24 New Permit Application
2013-09-21 Performed Spud Operation
2014-07-07 Perforation
2016-01-19 DEVIATED

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2014-07-08 2014-07-22 7,993 6,121,440 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Sand (Proppant) Universal Proppant Silica Substrate NA 100 9.49216 5,333,300.0
Hydrochloric Acid (7.5%) Axiall Acidizing Other - (non-hazardous) NA 92.5 1.0482 588945
Hydrochloric Acid 7647-01-0 7.5 0.0450442 25308.7
Hydrochloric Acid 7647-01-0 7.5 0.0186976 10505.5
Hydrochloric Acid 7647-01-0 7.5 0.0212473 11938.1
Scale Inhibitor, ScaleHib A Nalco Scale Inhibitor Other - (non-hazardous) NA 70 0.00748068 4203.13
Ethylene Glycol 107-21-1 30 0.00320601 1801.34
Friction Reducer, Unislick ST-50 CESI Chemical Friction Reducer Other - (non-hazardous) NA 70 0.0464783 26114.5
Petroleum distillates, hydrotreated light 64742-47-8 30 0.0199193 11191.9
Biocide, EC6116A Nalco Biocide Dibromoacetonitrile 3252-43-5 5 0.00051055 286.859
Polyethylene Glycol 25322-68-3 60 0.0061266 3442.31
2,2-Dibromo-3-nitrilopropionamide 10222-01-2 30 0.0030633 1721.16
Other - (non-hazardous) NA 5 0.00051055 286.859
Water XTO Carrier/Base Fluid Water 7732-18-5 100 88.9887 49,999,600.0
Hydrochloric Acid (15%) Axiall Acidizing Hydrochloric Acid 7647-01-0 15 0.0236808 13305.4
Hydrochloric Acid 7647-01-0 15 0.00982975 5522.98
Hydrochloric Acid 7647-01-0 15 0.0111702 6276.11
Other - (non-hazardous) NA 85 0.25319 142259
Acid Inhibitor, Unihib G GeoSafe Acid Inhibitor Short chained glycol ether 112-34-5 60 0.000448808 252.169
Methanol 67-56-1 5 0.00003740 21.014
Ethoxylated alcohol 68002-97-1 35 0.000261804 147.098
Formaldehyde 50-00-0 1 0.00000748 4.203
Acetophenone 98-86-2 1 0.00000748 4.203
Thiourea 62-56-6 1 0.00000748 4.203

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2013 XTO ENERGY INC 0.00 0 0.00 0 0.00 0
2014 XTO ENERGY INC 0.00 0 0.00 0 0.00 0
2015 XTO ENERGY INC 0.00 0 0.00 0 0.00 0
2016 XTO ENERGY INC 0.00 0 0.00 0 0.00 0
2017 XTO ENERGY INC 0.00 0 0.00 0 0.00 0
2019 XTO ENERGY INC 0.00 0 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2013 XTO ENERGY INC Drill Cuttings 1,230.00 Tons LANDFILL 100434

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2207500 Primary Facility 2013-09-23 Drilling/Alteration No Violations Noted 80' of 24" conductor set 9-21-13
2208372 Primary Facility 2013-09-27 Drilling/Alteration No Violations Noted
2212433 Primary Facility 2013-10-09 Routine/Complete Inspection No Violations Noted
2212523 Primary Facility 2013-10-01 Routine/Complete Inspection No Violations Noted Rig currently cementing well 3H. 2H, 1H not yet drilled.Tanks within lined secondary containment units.Site ID on-site, in compliance with Act 9 standards. ESCGP-2, E&S plan, PPC plan, PCSM, valid drilling permits for 1H, 2H, 3H all on-site.Access road adequately rocked, in good condition. Site mulched, temporarily stabilized. Department recommends Operator rock ditches along pad perimeter if issues arise with current vegetative matting and continue to monitor and maintain E&S BMPs.Inspt in response to record 2207614 in which Department requested on-site meeting with Operator. Present XTO representatives include Tom Baun, Matt Streams, Erik Greenert, Jason, and XTO consultant Mike Vale. Present Department representatives include April Weiland, Mark Millward, and myself.
2216566 Primary Facility 2013-10-24 Drilling/Alteration No Violations Noted
2218634 Primary Facility 2013-10-31 Drilling/Alteration No Violations Noted
2219144 Primary Facility 2013-10-31 Routine/Complete Inspection No Violations Noted At time of inspection, rig on-site. 3H drilled. 2H, 1H not yet spudded. Rig on secondary containment. Tanks within lined secondary containment units.
2228686 Primary Facility 2013-12-11 Routine/Complete Inspection No Violations Noted At time of inspection, rig not on-site. 3H drilled. 2H, 1H not yet spudded. Gate around 3H.
2244679 Primary Facility 2014-02-11 Routine/Partial Inspection No Violations Noted RTPT inspt. Inspection conducted with OGI Rick Hoover.
2255349 Primary Facility 2014-03-20 Routine/Complete Inspection No Violations Noted Marcellus. At time of inspection, rig not on-site. 3H drilled, not yet frac'd. 2H, 1H not yet spudded. Gate around 3H.
2288789 Primary Facility 2014-07-22 Routine/Complete Inspection No Violations Noted Marcellus. At time of inspection, frac'g operations on 3H just concluding. 2H not yet spudded.
2292074 Primary Facility 2014-07-22 Drilling/Alteration No Violations Noted
2416513 Primary Facility 2015-10-05 Complaint Inspection No Violations Noted Single well unconventional pad. According to records well currently in regulatory in-active status.
2541973 Primary Facility 2016-12-01 Routine/Complete Inspection No Violations Noted Marcellus. At time of inspection, well 3H drilled. According to records, drilling occurred 9/24/2013-10/30/2013 and inactive status granted on 4/15/2015.

Site ID sign on-site, appears to be in compliance with Act 9 standards. ESCGP-2, E&S/PCSM/Restoration plans, PPC plan, and ERP on-site. Well tag present, legible. Brine tank located in secondary containment unit, both appear sound. Access road gated, stabilized. Well pad stabilized. The areas surrounding sediment basin 1 are not yet permanently stabilized. These areas are temporarily stabilized with seed/mulch with minimal growth observed. The Department recommends the Operator continue to monitor and maintain these areas to ensure that >70% uniform and adequate vegetation is achieved for final permanent stabilization of the site. PCSM BMPs appear to be installed in accordance with the PCSM plan. The Department recommends that the Operator continue to monitor and maintain all BMPs as necessary in order to prevent any potential pollution events from occur

2613763 Primary Facility 2017-06-29 Routine/Complete Inspection No Violations Noted Marcellus. At time of inspection, well drilled and appears equipped for production. Well tag present, legible. Well surrounded by fence.

Following this inspection, the Department notified operator representative Matt Thomas of the above-noted observations via phone (Waste Management General). Mr. Thomas agreed to promptly investigate and follow-up with the Department. At 1405, Mr. Thomas notified the Department via phone that the staining was diesel fluid, most likely from a third party piece of equipment. All visibly impacted materials have been excavated in accordance with the Department's Spill Policy and will be disposed of properly. Per Mr. Thomas, the gravel in the cellar is wet due to water accumulation from recent rainfalls. Because the cellar is cemented, the water is unable to drain; there is no oil/petroleum product in the cellar. No violations are being noted at this time.

2615906 Primary Facility 2017-07-13 Routine/Partial Inspection No Violations Noted RTPT inspection conducted in response to inspection record 2613763.
2664252 Primary Facility 2017-11-21 Routine/Complete Inspection No Violations Noted Inspection conducted in response to restoration report submitted by the operator. Operator representative Kevin Brucha present during inspection.

At time of inspection, well is under Regulatory Inactive Status.

Well site appears to be restored and is permanently stabilized with greater than 70% uniform and adequate vegetative growth.