37-059-26193

Well Details

Well ID: 37-059-26193
Loading map...
Country: United States
State: Pennsylvania
County: Greene
Municipality: Morris Township
Operator Name: EQT PROD CO
Well Pad ID: 145491
Farm/Lease Name: J MONINGER 591538
License Status:
Spud Date:
Permit Date: 2013-05-24
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 39.971572
Longitude: -80.264664

For data sources see[1][2][3]

Well History

Date Event
2013-05-24 New Permit Application
2013-12-23 New Permit Application
2014-04-30 Performed Spud Operation
2014-08-19 New Permit Application
2015-09-02 Perforation
2015-09-02 Performed Stimulation
2016-03-16 DEVIATED
2016-04-28 Drilling Completion

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2015-09-02 2015-09-17 7,913 9,288,300 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 NE-100 FTS International Non-emulsifier Dodecylbenzenesulfonic acid 27176-87-0 5 0.00001849 16.11
2-Propanol 67-63-0 10 0.00003698 32.22
2-Butoxyethanol 111-76-2 10 0.00003698 32.22
CI-150 FTS International Acid Corrosion Inhibitor Isopropanol 67-63-0 30 0.000116629 101.617
Organic amine resin salt Proprietary 30 0.000116629 101.617
Ethylene Glycol 107-21-1 30 0.000116629 101.617
Dimethylformamide 68-12-2 10 0.00003888 33.872
Aromatic aldehyde Proprietary 10 0.00003888 33.872
Quaternary ammonium compound Proprietary 10 0.00003888 33.872
FE-100L FTS International Iron Control Citric Acid 77-92-9 55 0.000745917 649.909
Hydrochloric Acid (15%) FTS International Acidizing Hydrochloric Acid 7647-01-0 15 0.0315133 27457.1
MC MX 437-5 Muli-Chem Group Calcium Nitrate Solution Calcium Nitrate 10124-37-5 60 0.0566691 49375.1
FRW-900 FTS International Friction Reducer Hydrotreated Light Distillate 64742-47-8 30 0.0219562 19130.2
Alkyl Alcohol Proprietary 10 0.00731872 6376.72
Oxyalkylated Alcohol A Proprietary 5 0.00365936 3188.36
Sand (Proppant) FTS International Proppant Silica Substrate 14808-60-7 100 10.6341 9,265,350.0
Water FTS International Carrier/Base Fluid Water 7732-18-5 100 88.9612 77,510,900.0
CS-500-SI FTS International Scale Inhibitor Ethylene Glycol 107-21-1 10 0.0024905 2169.95

For data sources see[5]

Stimulation Data

Stimulation Date Phase Number Chemical Agent Volume (gal) Treating Pressure (psi) Breakdown Pressure (psi)
2015-09-02 0 0 0

For data sources see[6]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2014 EQT PROD CO 0.00 0 0.00 0 0.00 0
2015 EQT PROD CO 57,444.00 9 0.00 0 0.00 0
2016 EQT PROD CO 2,129,227.00 355 0.00 0 0.00 0
2017 EQT PROD CO 913,270.00 365 0.00 0 0.00 0
2018 EQT PROD CO 645,834.00 365 0.00 0 0.00 0
2019 EQT PROD CO 414,197.00 365 0.00 0 0.00 0

For data sources see[7]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2014 EQT PROD CO Drill Cuttings 576.97 Tons LANDFILL 100419
2014 EQT PROD CO Drilling Fluid Waste 740.00 Bbl REUSE OTHER THAN ROAD SPREADING
2014 EQT PROD CO Fracing Fluid Waste 130.00 Bbl REUSE OTHER THAN ROAD SPREADING
2015 EQT PROD CO Drilling Fluid Waste 110.00 Bbl REUSE OTHER THAN ROAD SPREADING
2015 EQT PROD CO Drill Cuttings 619.00 Tons LANDFILL 100419
2015 EQT PROD CO Fracturing Fluid Waste 10.27 Tons LANDFILL 101571
2015 EQT PROD CO Produced Fluid 1,788.00 Bbl REUSE OTHER THAN ROAD SPREADING
2015 EQT PROD CO Fracing Fluid Waste 10,026.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016 EQT PROD CO Produced Fluid 112.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2016 EQT PROD CO Other Oil & Gas Wastes 332.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016 EQT PROD CO Produced Fluid 772.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW005
2016 EQT PROD CO Produced Fluid 33,531.00 Bbl REUSE OTHER THAN ROAD SPREADING
2017 EQT PROD CO Produced Fluid 295.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2017 EQT PROD CO Produced Fluid 130.00 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2017 EQT PROD CO Other Oil & Gas Wastes 40.00 Bbl REUSE (AT WELL PAD)
2017 EQT PROD CO Produced Fluid 130.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW010
2017 EQT PROD CO Produced Fluid 2,392.00 Bbl REUSE (AT WELL PAD)
2018 EQT PROD CO Other Oil & Gas Wastes 110.00 Bbl REUSE (AT WELL PAD)
2018 EQT PROD CO Produced Fluid 377.51 Bbl REUSE (AT WELL PAD)
2018 EQT PROD CO Produced Fluid 34.95 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018 EQT PROD CO Produced Fluid 155.70 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2019 EQT PROD CO Produced Fluid 70.18 Bbl SURFACE IMPOUNDMENT 95-7-37312-19
2019 EQT PROD CO Other Oil & Gas Wastes 8.46 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2019 EQT PROD CO Other Oil & Gas Wastes 9.23 Bbl SURFACE IMPOUNDMENT 95-7-37312-19
2019 EQT PROD CO Other Oil & Gas Wastes 9.23 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2019 EQT PROD CO Produced Fluid 53.85 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2019 EQT PROD CO Other Oil & Gas Wastes 204.61 Bbl REUSE (AT WELL PAD)
2019 EQT PROD CO Produced Fluid 1,273.52 Bbl REUSE (AT WELL PAD)
2019 EQT PROD CO Produced Fluid 52.42 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW010

For data sources see[8]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2281045 Primary Facility 2014-06-09 Drilling/Alteration No Violations Noted 40' OF 20" CONDUCTOR SET. ALPHA HUNTER RIG 8 ON SITE DRILLING TOP HOLE SETS.
2363612 Primary Facility 2015-03-11 Routine/Complete Inspection No Violations Noted Well drilled to TVD, Patterson 227 on site to complete TD.
2466994 Primary Facility 2016-03-18 Routine/Complete Inspection No Violations Noted Well operating and is properly identified. Well is equipped with a production unit. Wellhead and piping appear to be in good condition.
2569062 Primary Facility 2017-03-08 Routine/Complete Inspection No Violations Noted On Monday, March 6, 2017, I conducted a routine/complete inspection at the J. Moninger OG Well Pad located in Morris Township, Greene County.

The Act 9 Sign was in place and clearly legible at the site entrance, as were the gas well API identification signs below the Act 9 signs. All required documentation was also available on-site.

The access road and well pad were in good condition. Some minor rill formation was observed on the access road. The operator should continue their periodic monitoring program and conduct maintenance as warranted.

All PCSM controls have been installed according to plans and are functioning as intended. The site is stabilized via a combination of lush vegetative growth, seed and erosion control matting. The most recent seeded areas exhibit some vegetative growth. The operator should continue their periodic monitoring program and mitigate any signs of accelerated erosion and sediment movement upon identification.

The secondary containment structures on-site are in good co

2589852 Primary Facility 2017-05-03 Site Restoration No Violations Noted On Wednesday, May 3, 2017, I conducted a restoration inspection at the J Moninger OG Well Site located in Morris Township, Greene County. The inspection was the result of an operator submittal of Well Site Restoration Reports in accordance with 25 Pa. Code Section 78.65(3). The well site restoration is an interim restoration while the gas wells on the pad remain in the production stage. The inspection was conducted to confirm that the interim restoration was completed in accordance with the operator's site restoration plan.

Inspection of the site confirmed that the site has been restored to the configuration depicted on the restoration plans.

No violations were identified during the inspection.

For data sources see[9]

References