37-059-25774

Well Details

Well ID: 37-059-25774
Loading map...
Country: United States
State: Pennsylvania
County: Greene
Municipality: Morgan Township
Operator Name: CHEVRON APPALACHIA LLC
Well Pad ID: 149148
Farm/Lease Name: RANKIN UNIT 4H
License Status:
Spud Date:
Permit Date: 2011-06-29
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: Yes
Latitude: 39.996814
Longitude: -80.060017

For data sources see[1][2][3]

Well History

Date Event
2011-06-29 New Permit Application
2011-09-08 Performed Spud Operation
2012-11-06 Perforation
2012-11-06 Performed Stimulation
2012-12-31 Drilling Completion
2013-05-24 DEVIATED

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2012-10-25 2012-10-25 7,000 4,539,339

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 WG-36 GELLING AGENT Halliburton Energy Services Water Viscosifier Guar gum 9000-30-0 100.00 0.00274000
7.5 Hcl Acid Used to open perfs Hydrochloric acid 7647-01-0 7.50 0.30
Biocide EC 6116A Nalco Biocide 2,2-Dibromo-3-nitrilopropionamide 10222-01-2 30.00 0.00755000
Dibromoacetonitrile 3252-43-5 5.00 0.00126000
Polyethylene glycol 25322-68-3 60.00 0.01
GBW-30 BREAKER Halliburton Energy Services Gel Breaker Hemicellulase enzyme 9012-54-8 15.00 0.00001000
Carbohydrates 95.00 0.00008000
FR-66 Friction Reducer Halliburton Energy Services Friction Reducer Distillates, petroleum, hydrotreated light 64742-47-8 30.00 0.03
Clean Volume (gals) Carrier/Base Fluid 90.94 100.00
Proppant (lbs) Proppant 9.06 10.04
ASP 900 Nalco Friction Reducer Ammonium sulfate 7783-20-2 30.00
EC6486A Nalco Scale Inhibitor Ethylene glycol 107-21-1 30.00 0.00745000
EC6673W Nalco Iron Control Ethylene glycol 107-21-1 30.00 0.00698000

For data sources see[5]

Stimulation Data

Stimulation Date Phase Number Chemical Agent Volume (gal) Treating Pressure (psi) Breakdown Pressure (psi)
2012-11-06 0 0 0

For data sources see[6]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2011 CHEVRON APPALACHIA LLC 0.00 0 0.00 0 0.00 0
2012 CHEVRON APPALACHIA LLC 0.00 0 0.00 0 0.00 0
2013 CHEVRON APPALACHIA LLC 800,434.00 365 0.00 0 0.00 0
2014 CHEVRON APPALACHIA LLC 524,281.00 334 0.00 0 0.00 0
2015 CHEVRON APPALACHIA LLC 355,895.00 365 0.00 0 0.00 0
2016 CHEVRON APPALACHIA LLC 264,501.00 366 0.00 0 0.00 0
2017 CHEVRON APPALACHIA LLC 229,442.00 365 0.00 0 0.00 0
2018 CHEVRON APPALACHIA LLC 183,681.00 365 0.00 0 0.00 0
2019 CHEVRON APPALACHIA LLC 176,261.00 365 0.00 0 0.00 0

For data sources see[7]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2012 CHEVRON APPALACHIA LLC Drilling Fluid Waste 130.00 Bbl REUSE OTHER THAN ROAD SPREADING
2012 CHEVRON APPALACHIA LLC Drill Cuttings 0.95 Tons LANDFILL 100419
2012 CHEVRON APPALACHIA LLC Fracing Fluid Waste 144.00 Bbl REUSE OTHER THAN ROAD SPREADING
2012 CHEVRON APPALACHIA LLC Drilling Fluid Waste 2,220.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW001
2013 CHEVRON APPALACHIA LLC Produced Fluid 2,790.00 Bbl REUSE OTHER THAN ROAD SPREADING
2013 CHEVRON APPALACHIA LLC Fracing Fluid Waste 476.70 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW001
2013 CHEVRON APPALACHIA LLC Produced Fluid 80.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW001
2013 CHEVRON APPALACHIA LLC Fracing Fluid Waste 26,690.00 Bbl REUSE OTHER THAN ROAD SPREADING
2013 CHEVRON APPALACHIA LLC Fracing Fluid Waste 4,700.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW001
2014 CHEVRON APPALACHIA LLC Fracturing Fluid Waste 65.81 Tons STORAGE PENDING DISPOSAL OR REUSE MID074259565
2014 CHEVRON APPALACHIA LLC Produced Fluid 36.67 Bbl INJECTION DISPOSAL WELL 34-121-23995
2014 CHEVRON APPALACHIA LLC Produced Fluid 1,878.34 Bbl REUSE OTHER THAN ROAD SPREADING
2014 CHEVRON APPALACHIA LLC Drill Cuttings 15.79 Tons LANDFILL 100172
2015 CHEVRON APPALACHIA LLC Produced Fluid 1,162.33 Bbl REUSE OTHER THAN ROAD SPREADING
2016 CHEVRON APPALACHIA LLC Produced Fluid 139.16 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW019
2016 CHEVRON APPALACHIA LLC Produced Fluid 657.68 Bbl REUSE OTHER THAN ROAD SPREADING
2017 CHEVRON APPALACHIA LLC Produced Fluid 159.55 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2017 CHEVRON APPALACHIA LLC Produced Fluid 76.67 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2017 CHEVRON APPALACHIA LLC Produced Fluid 76.67 Bbl INJECTION DISPOSAL WELL 34-157-25511
2017 CHEVRON APPALACHIA LLC Produced Fluid 3,721.67 Bbl REUSE (AT WELL PAD)
2018 CHEVRON APPALACHIA LLC Produced Fluid 73.33 Bbl REUSE (AT WELL PAD)
2018 CHEVRON APPALACHIA LLC Produced Fluid 109.99 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2018 CHEVRON APPALACHIA LLC Produced Fluid 164.67 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2019 CHEVRON APPALACHIA LLC Produced Fluid 519.99 Bbl REUSE (AT WELL PAD)
2019 CHEVRON APPALACHIA LLC Produced Fluid 40.00 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA

For data sources see[8]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2034845 Primary Facility 2012-01-09 Drilling/Alteration No Violations Noted PIONEER RIG 61 READY TO MOVE TO THIS HOLE. THE CONDUCTOR IS IN AND SET AT 107;.
2134782 Primary Facility 2013-01-31 Routine/Complete Inspection No Violations Noted Wells are drilled and fracked. Currently flowing back sand and water finishing the well. E/S controls are in good condition around site and is temp, stabilized. The E/S controls on the access road near the stream may need inspected by the Operator and place new straw bales to prevent sediment from reaching stream.
2339264 Primary Facility 2014-12-15 Routine/Complete Inspection No Violations Noted Well in production. Well in compliance.
2581191 Primary Facility 2017-04-11 Routine/Complete Inspection No Violations Noted The Act 9 sign was in place and all required documents were present at the site. The site overall was well vegetated, but there was a small bare spot that is recommended be addressed. There was what appeared to be a metal pipe on the pad that is recommended be removed. The production equipment appeared to be in good condition. There were no violations observed at the time of inspection.

For data sources see[9]

References