Well ID: 37-059-25450 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":39.953222,"lon":-80.276583,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Greene | |
Municipality: Morris Township | |
Operator Name: EQT PROD CO | |
Well Pad ID: 148308 | |
Farm/Lease Name: F IAMS 590455 | |
License Status: | |
Spud Date: | |
Permit Date: 2010-03-29 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: Yes | |
Latitude: 39.953222 | |
Longitude: -80.276583 |
Date | Event |
---|---|
2010-03-29 | New Permit Application |
2010-06-09 | Performed Spud Operation |
2011-03-03 | Drilling Completion |
2012-08-17 | DEVIATED |
For data sources see[4]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2011-07-26 | 2011-07-26 | 7,832 | 6,818,448 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | FR-66 | Halliburton | Friction Reducer | Hydrotreated light petroleum distillate | 64742-47-8 | 30.0 | 31.8007 | |
GBW-30 | Halliburton | Enzyme Breaker | Hemicellulase Enzyme | 9012-54-8 | 15.0 | 22.5 | ||
HCl | Halliburton | 15 HCl Acid | Hydrochloric Acid | 7647-01-0 | 28.0 | 32.9412 | ||
BA-40L | Halliburton | Buffer | Potassium carbonate | 584-08-7 | 60.0 | 89.76 | ||
SP Breaker | Halliburton | Oxidizing Breaker | Sodium Persulfate | 7775-27-1 | 100.0 | 247.0 | ||
LGC-36 | Halliburton | Gelling Agent | Guar Gum | 9000-30-0 | 30.0 | 31.0084 | ||
Halliburton | Gelling Agent | Naptha, hydrotreated heavy | 64742-48-9 | 30.0 | 31.0084 | |||
Methanol | 67-56-1 | 60.0 | 70.5882 | |||||
Propargyl Alcohol | 107-19-7 | 10.0 | 11.7647 | |||||
LP-65 | Halliburton | Scale Inhibitor | Ammonium chloride | 12125-02-9 | 10.0 | 11.7647 | ||
BE-9 | Halliburton | Biocide | Tributyl tetradecyl phosphonium chloride | 81741-28-8 | 10.0 | 9.7479 | ||
Halliburton | Corrosion Inhibitor |
For data sources see[5]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2010 | EQT PROD CO | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2011 | EQT PROD CO | 1,324,083.00 | 122 | 0.00 | 0 | 0.00 | 0 |
2012 | EQT PROD CO | 2,150,191.00 | 366 | 0.00 | 0 | 0.00 | 0 |
2013 | EQT PROD CO | 1,264,798.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2014 | EQT PROD CO | 924,328.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2015 | EQT PROD CO | 771,343.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2016 | EQT PROD CO | 688,411.00 | 364 | 0.00 | 0 | 0.00 | 0 |
2017 | EQT PROD CO | 608,222.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2018 | EQT PROD CO | 426,425.00 | 348 | 0.00 | 0 | 0.00 | 0 |
2019 | EQT PROD CO | 468,736.00 | 347 | 0.00 | 0 | 0.00 | 0 |
For data sources see[6]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2011 | EQT PROD CO | Drilling Fluid Waste | 268.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2011 | EQT PROD CO | Produced Fluid | 1,984.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | 34-167-28466 |
2011 | EQT PROD CO | Drilling Fluid Waste | 110.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0095443 |
2011 | EQT PROD CO | Drilling Fluid Waste | 1,100.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | 301353 |
2011 | EQT PROD CO | Produced Fluid | 900.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | |
2011 | EQT PROD CO | Produced Fluid | 121.00 Bbl | INJECTION DISPOSAL WELL | 34-059-24067 |
2011 | EQT PROD CO | Produced Fluid | 1,812.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2011 | EQT PROD CO | Produced Fluid | 315.00 Bbl | INJECTION DISPOSAL WELL | 34-009-22704 |
2011 | EQT PROD CO | Fracing Fluid Waste | 1,700.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2011 | EQT PROD CO | Produced Fluid | 343.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | 34-121-23390 |
2012 | EQT PROD CO | Fracing Fluid Waste | 110.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2012 | EQT PROD CO | Produced Fluid | 5,518.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2012 | EQT PROD CO | Produced Fluid | 1,113.00 Bbl | INJECTION DISPOSAL WELL | 34-167-28466 |
2012 | EQT PROD CO | Produced Fluid | 100.00 Bbl | INJECTION DISPOSAL WELL | 34-121-23390 |
2012 | EQT PROD CO | Produced Fluid | 1,306.00 Bbl | INJECTION DISPOSAL WELL | 34-167-29577 |
2012 | EQT PROD CO | Produced Fluid | 1,207.00 Bbl | INJECTION DISPOSAL WELL | 34-059-24067 |
2013 | EQT PROD CO | Produced Fluid | 4,731.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2013 | EQT PROD CO | Produced Fluid | 110.00 Bbl | INJECTION DISPOSAL WELL | 34-155-21438 |
2014 | EQT PROD CO | Produced Fluid | 2,791.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2015 | EQT PROD CO | Produced Fluid | 2,270.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016 | EQT PROD CO | Other Oil & Gas Wastes | 55.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016 | EQT PROD CO | Produced Fluid | 5,189.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016 | EQT PROD CO | Synthetic Liner Materials | 2.31 Tons | LANDFILL | 100419 |
2016 | EQT PROD CO | Produced Fluid | 50.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123SW019 |
2016 | EQT PROD CO | Produced Fluid | 257.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2017 | EQT PROD CO | Produced Fluid | 181.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2017 | EQT PROD CO | Produced Fluid | 958.36 Bbl | REUSE (AT WELL PAD) | |
2018 | EQT PROD CO | Other Oil & Gas Wastes | 46.66 Bbl | REUSE (AT WELL PAD) | |
2018 | EQT PROD CO | Produced Fluid | 762.25 Bbl | REUSE (AT WELL PAD) | |
2018 | EQT PROD CO | Produced Fluid | 60.84 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2019 | EQT PROD CO | Produced Fluid | 98.38 Bbl | SURFACE IMPOUNDMENT | 95-7-37312-19 |
2019 | EQT PROD CO | Produced Fluid | 53.94 Bbl | INJECTION DISPOSAL WELL | 34-167-29543 |
2019 | EQT PROD CO | Produced Fluid | 53.94 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2019 | EQT PROD CO | Produced Fluid | 72.77 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2019 | EQT PROD CO | Produced Fluid | 5,749.26 Bbl | REUSE (AT WELL PAD) | |
2019 | EQT PROD CO | Produced Fluid | 50.46 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW010 |
For data sources see[7]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2006675 | Primary Facility | 2011-09-29 | Drilling/Alteration | No Violations Noted | ` |
2189101 | Primary Facility | 2013-07-25 | Routine/Complete Inspection | No Violations Noted | Routine Inspection Well compliant at time of inspection. |
2397356 | Primary Facility | 2015-05-06 | Routine/Complete Inspection | No Violations Noted | Well in production. Well in compliance. |
2680874 | Primary Facility | 2018-01-09 | Routine/Complete Inspection | No Violations Noted | On Tuesday, January 9, 2018, I conducted a routine-complete inspection at the F Iams Well Site located in Morris Township, Greene County.
The gas well 590455 (059-25450) and associated infrastructure appeared to be in good condition and functioning properly. The well was labelled. No violations were identified during the inspection. |