If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-059-25313 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":39.86908,"lon":-80.012668,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Greene | |
Municipality: Cumberland Township | |
Operator Name: GREYLOCK PROD LLC | |
Well Pad ID: 148446 | |
Farm/Lease Name: GRIBBLE UNIT 1MH | |
License Status: | |
Spud Date: | |
Permit Date: 2009-09-23 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: Yes | |
Latitude: 39.869080 | |
Longitude: -80.012668 |
Date | Event |
---|---|
2009-09-23 | New Permit Application |
2009-11-01 | Performed Spud Operation |
For data sources see[4]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2010-08-14 | 2010-08-14 | 8,142 | 3,326,946 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | PSP-100 Mesh Proppant | Pumpco | Proppant | Crystalline silica quartz | 14808-60-7 | 99.9 | 2.81846 | |
Water | ECA | Base Fluid | 100.0 | 89.46965 | ||||
Greenhib 677 | Pumpco | Scale Inhibitor | Salt of phosphono-methylated diamine | N/A | 25.0 | 0.00666 | ||
Plexgel 907 LE | Pumpco | Liquid Gel | Hydrocarbons | 68476-34-6 | 70.0 | 0.00833 | ||
P-HCI 15 HCI | Pumpco | Acid | Hydrogen Chloride | 7647-01-0 | 15.0 | 0.07055 | ||
Ammonium Persulfate | Pumpco | Breaker | Ammonium Persulfate | 7727-54-0 | 100.0 | 0.0017 | ||
Plexhib 256 | Pumpco | Corrosion Inhibitor for Acid | Propargyl Alcohol | 107-19-7 | 8.0 | 0.00006000 | ||
Methyl Alcohol | 67-56-1 | 40.0 | 0.0003 | |||||
Ferriplex 40 | Pumpco | Iron Control for Acid | Sodium Hydroxide | 1310-73-2 | 1.0 | 0.00002000 | ||
Sodium Sulfate Anhydrous | 7757-82-6 | 2.0 | 0.00004000 | |||||
Trisodium Nitrilotriacetate | 18662-53-8 | 40.0 | 0.00089 | |||||
Plexslick 921 | Pumpco | Friction Reducer | Petroleum Distillate | 64742-47-8 | 30.0 | 0.02217 | ||
PBC-24-L Microbiocide | Pumpco | Biocide | Tetrahydro-3, 5-Dimethyl-2H-1,3,5-thiadiazine-2-thione | 533-74-4 | 24.0 | 0.00285 | ||
Sodium Hydroxide | 1310-73-2 | 4.0 | 0.00047 | |||||
PSP-40/70 Ottawa Proppant | Pumpco | Proppant | Crystalline silica quartz | 14808-60-7 | 99.9 | 7.59784 |
For data sources see[5]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2009 | ENERGY CORP OF AMER | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2010 | ENERGY CORP OF AMER | 355,728.00 | 128 | 0.00 | 0 | 0.00 | 0 |
2011 | ENERGY CORP OF AMER | 475,975.00 | 312 | 0.00 | 0 | 0.00 | 0 |
2012 | ENERGY CORP OF AMER | 333,327.00 | 272 | 0.00 | 0 | 0.00 | 0 |
2013 | ENERGY CORP OF AMER | 245,328.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2014 | ENERGY CORP OF AMER | 199,760.00 | 361 | 0.00 | 0 | 0.00 | 0 |
2015 | ENERGY CORP OF AMER | 171,104.00 | 351 | 0.00 | 0 | 0.00 | 0 |
2016 | ENERGY CORP OF AMER | 139,733.00 | 363 | 0.00 | 0 | 0.00 | 0 |
2017 | ENERGY CORP OF AMER | 116,114.00 | 333 | 0.00 | 0 | 0.00 | 0 |
2018 | GREYLOCK PROD LLC | 107,347.00 | 363 | 0.00 | 0 | 0.00 | 0 |
2019 | GREYLOCK PROD LLC | 109,491.00 | 361 | 0.00 | 0 | 0.00 | 0 |
For data sources see[6]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2010 | ENERGY CORP OF AMER | Produced Fluid | 1,029.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2011 | ENERGY CORP OF AMER | Drilling Fluid Waste | 43.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2011 | ENERGY CORP OF AMER | Fracturing Fluid Waste | 80.50 Tons | LANDFILL | 100172 |
2011 | ENERGY CORP OF AMER | Produced Fluid | 3,277.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2011 | ENERGY CORP OF AMER | Fracing Fluid Waste | 468.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2011 | ENERGY CORP OF AMER | Produced Fluid | 145.00 Bbl | STORAGE PENDING DISPOSAL OR REUSE | |
2011 | ENERGY CORP OF AMER | Drill Cuttings | 179.17 Tons | LANDFILL | 100172 |
2012 | ENERGY CORP OF AMER | Produced Fluid | 850.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2012 | ENERGY CORP OF AMER | Fracturing Fluid Waste | 130.38 Tons | LANDFILL | 100277 |
2013 | ENERGY CORP OF AMER | Produced Fluid | 413.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2014 | ENERGY CORP OF AMER | Produced Fluid | 495.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2015 | ENERGY CORP OF AMER | Produced Fluid | 60.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123SW001 |
2015 | ENERGY CORP OF AMER | Basic Sediment | 17.78 Bbl | LANDFILL | 100172 |
2015 | ENERGY CORP OF AMER | Produced Fluid | 234.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016 | ENERGY CORP OF AMER | Produced Fluid | 28.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW010 |
2016 | ENERGY CORP OF AMER | Produced Fluid | 48.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016 | ENERGY CORP OF AMER | Produced Fluid | 169.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123SW001 |
2016 | ENERGY CORP OF AMER | Produced Fluid | 21.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123SW019 |
2016 | ENERGY CORP OF AMER | Produced Fluid | 40.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW001 |
2017 | ENERGY CORP OF AMER | Other Oil & Gas Wastes | 0.83 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW010 |
2017 | ENERGY CORP OF AMER | Produced Fluid | 227.00 Bbl | REUSE (AT WELL PAD) | |
2017 | ENERGY CORP OF AMER | Produced Fluid | 2,238.62 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW010 |
2018 | ENERGY CORP OF AMER | Produced Fluid | 30.00 Bbl | CENT WASTE TRT FAC NPDES | WVR00521948 |
2018 | ENERGY CORP OF AMER | Produced Fluid | 30.00 Bbl | CENT WASTE TRT FAC NPDES DISCHARGE | WVR00521948 |
2018 | GREYLOCK PROD LLC | Other Oil & Gas Wastes | 3.33 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW019 |
2018 | GREYLOCK PROD LLC | Other Oil & Gas Wastes | 19.43 Bbl | INJECTION DISPOSAL WELL | 34-155-24079 |
2018 | GREYLOCK PROD LLC | Produced Fluid | 69.00 Bbl | INJECTION DISPOSAL WELL | 34-155-24079 |
2018 | GREYLOCK PROD LLC | Produced Fluid | 131.00 Bbl | REUSE (AT WELL PAD) | |
2019 | GREYLOCK PROD LLC | Other Oil & Gas Wastes | 20.66 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW031 |
2019 | GREYLOCK PROD LLC | Produced Fluid | 198.00 Bbl | REUSE (AT WELL PAD) | |
2019 | GREYLOCK PROD LLC | Produced Fluid | 78.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW010 |
2019 | GREYLOCK PROD LLC | Other Oil & Gas Wastes | 46.06 Bbl | REUSE (AT WELL PAD) | |
2019 | GREYLOCK PROD LLC | Other Oil & Gas Wastes | 51.38 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW010 |
2019 | GREYLOCK PROD LLC | Other Oil & Gas Wastes | 0.11 Bbl | SURFACE IMPOUNDMENT | 95-7-37312-21 |
2019 | GREYLOCK PROD LLC | Produced Fluid | 38.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW031 |
For data sources see[7]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
1843146 | Primary Facility | 2009-11-06 | Drilling/Alteration | No Violations Noted | MARCELLUS HORIZONTAL SWJ 7 IS RUNNIGN A DEVIATION SURVEY ON THE GRIBBLE 2 MH. SWJ 36 IS MOVING IN TO DRILL BESIDE 7 ON THE SAME PAD. THE ROAD IS MUDDY FROM THE RIG MOVE |
1866688 | Primary Facility | 2010-02-01 | Drilling/Alteration | No Violations Noted | HORIZONTAL MARCELLUS |
1866696 | Primary Facility | 2010-02-24 | Drilling/Alteration | No Violations Noted | HORIZONTAL MARCELLUS |
1867582 | Primary Facility | 2010-03-01 | Routine/Complete Inspection | Violation(s) Noted | The Department was at the above referenced Marcellus Well to conduct a routine inspection. The Department observed a pit liner that was not structurally sound. The liner had been torn and the hole was approximately 6 feet long. The pit will need to be drained and its contents will have to be handled in accordance with Department regulations. The well site was prepared within 100 feet of a stream identified on a |
1876442 | Primary Facility | 2010-04-06 | Drilling/Alteration | No Violations Noted | HORIZONTAL MARCELLUS |
1884637 | Primary Facility | 2010-04-14 | Compliance Evaluation | No Violations Noted | The Department was at the above referenced Marcellus Well to conduct a CEI Inspection. The Department issued the Operator a NOV on 3/5/10 in regards to the pit leak and the waiver for the 100 ft distance restriction. The Operator has repaired the liner and is currently utilizing the pit for drilling. An unknown amount of drilling fluids leeched into the soil for an unknown amount of time. The Department discovered the leaking pit. The Operator failed to properly notify the Department. The Department has not received the waiver for the blue-line tributary to Muddy Creek. The Operator has disturbed soil and encroached on a stream without a permit (Less than 10 feet from stream) as mentioned in the 3/5/10 NOV. |
1884651 | Primary Facility | 2010-04-14 | Routine/Complete Inspection | Pending | The Department observed some environmental concerns while conducting a CEI Inspection at this site. These issues will be considered different from the 3/5/10 violations. The Department observed 2 acid rock seeps originating on the fill side slope. The Operator had contacted the Department because they encountered coal while excavating the impoundment. DEP Mining program was contacted to deal with the coal issues. The acid rock drainage will need to be addressed. |
1884685 | Primary Facility | 2010-04-15 | Follow-up Inspection | Pending | The Department observed some environmental concerns while conducting a CEI Inspection at this site. These issues will be considered different from the 3/5/10 violations. The Department observed 2 acid rock seeps originating on the fill side slope. The Operator had contacted the Department because they encountered coal while excavating the impoundment. DEP Mining program was contacted to deal with the coal issues. The acid rock drainage (ARD) will need to be addressed. The Department will contact the Operator to discuss the ARD. The inspection results are pending. Follow-up inspections will be conducted. |
1884705 | Primary Facility | 2010-04-22 | Follow-up Inspection | Pending | The Department was at the above referenced Marcellus Well to conduct a follow-up inspection. The Operator is currently drilling a Marcellus Well. The acid rock seeps on the fill side slope continue to drain down the hill. The Operator placed bags of soda ash in the channels to control the PH and catch the iron. The Operator is responsible for maintaining the treatment of that water. Inspections should be made on a regular basis to control the contaminant levels. The Department will continue to inspect these acid rock seeps. The inspection results are pending. |
1884754 | Primary Facility | 2010-05-10 | Follow-up Inspection | Pending | The Department was at the above referenced Marcellus Well to conduct a follow-up inspection. The Operator is currently drilling a Marcellus Well. The Department received a call claiming that the groundwater has been impacted down gradient of this site. The Department will contact the residents to schedule a sampling event. The acid rock seeps on the fill side slope continue to drain down the hill. The Operator placed bags of soda ash in the channels to control the PH and catch the iron. The Operator is responsible for maintaining the treatment of that water. Inspections should be made on a regular basis to control the contaminant levels. The Department will continue to inspect these acid rock seeps. The inspection results are pending. |
1889715 | Primary Facility | 2010-05-25 | Follow-up Inspection | Pending | The Department was at the above referenced Marcellus Well to conduct a follow-up inspection in regards to the acidic water seep on the fill side of the site. The Operator is currently drilling multiple Marcellus Wells on this pad. Coal was encountered when constructing the water impoundment. They disposed of the coal. The drilling pit contained excessive oil during inspection. The sediment trap and E/S controls need cleaned-out. The inspection result is pending. The Department will sample the water wells down gradient of this site. The Department received three complaints in regards to impacted water supply wells. |
1893229 | Primary Facility | 2010-06-15 | Drilling/Alteration | No Violations Noted | HORIZONTAL MARCELLUS |
1896930 | Primary Facility | 2010-06-08 | Routine/Complete Inspection | No Violations Noted | The Department was at the above referenced Marcellus Well to conduct a routine inspection. The Department was following-up on the process of the fresh water impoundment and the iron seep on the drill site. Orange acid/iron contaminated water continues to seep out of the fill side of the site. It appears that 3 water supplies have been impacted down gradient. Water samples were taken at these locations and the Department will discuss options with the Operator to resolve the impacts if necessary. |
1988601 | Primary Facility | 2011-06-15 | Complaint Inspection | Pending | |
2047779 | Primary Facility | 2012-01-31 | Routine/Complete Inspection | No Violations Noted | The Department was at the above referenced Marcellus Well to conduct an inspection. The Operator has drilled 6 wells on the pad. The wells are drilled and in production. There is an on-going water quality investigation at this site. The site has not been restored at this point but the Operator will begin work next week. The E/S controls are in working condition and temporary site stabilization has been obtained. There is no water pouring out of the fill side of the pad during this inspection. This is where the orange acidic water poured out of the pad. The Operator will determine how to control this water. |
2052327 | Primary Facility | 2012-03-02 | Routine/Complete Inspection | No Violations Noted | The Department was at the above referenced Marcellus Wells to conduct an inspection. The Operator has drilled and fracked the wells and they appear to be in production. There is an ongoing water quality investigation taking place at this site. The Operator hired Moody to install ground water monitoring wells to evaluate the ground water. The Operator was on site restoring a water impoundment. The site will need to be seeded and mulched after final grading. |
2290664 | Primary Facility | 2014-07-28 | Complaint Inspection | No Violations Noted | Tags, tanks, e&s ok. 6 wells onsite. |
2375176 | Primary Facility | 2015-04-14 | Routine/Complete Inspection | No Violations Noted | Well completed and is in production. Well in compliance. |
Inspection ID | Violation ID | Violation Date | Date Resolved | Violation Code | Violation Type | Violation Comments |
---|---|---|---|---|---|---|
1867582 | 582622 | 03/01/2010 | 2010-03-01 | 78.56LINER - Improperly lined pit | Administrative | |
1867582 | 582623 | 03/01/2010 | 2010-03-01 | 205B - Drilling w/in 100 ft of surface water or wetland w/o variance | Administrative |
Violation ID | Penalty ID | Penalty Code | Penalty Status | Penalty Date | Enforcement Date | Penalty Amount | Amount Collected |
---|---|---|---|---|---|---|---|
582622 | 255814 | NOV - Notice of Violation | Comply/Closed | 2010-04-14 | |||
582623 | 255814 | NOV - Notice of Violation | Comply/Closed | 2010-04-14 |
For data sources see[8]