37-051-24456

Well Details

Well ID: 37-051-24456
Loading map...
Country: United States
State: Pennsylvania
County: Fayette
Municipality: German Township
Operator Name: CHEVRON APPALACHIA LLC
Well Pad ID: 148486
Farm/Lease Name: HARTLEY UNIT 10H
License Status:
Spud Date:
Permit Date: 2011-08-25
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: Yes
Latitude: 39.914014
Longitude: -79.883433

For data sources see[1][2][3]

Well History

Date Event
2011-08-25 New Permit Application
2011-12-28 Performed Spud Operation
2012-08-24 Drilling Completion
2013-03-22 Perforation
2013-03-22 Performed Stimulation
2016-04-25 DEVIATED

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2013-03-22 2013-03-22 8,229 5,769,780

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 GBW-30 Halliburton Gel Breaker Hemicellulase enzyme 9012-54-8 15 0.00009000 0
Carbohydrates 87246-72-8 95 0.00055 0
EC 6116a Nalco Biocide 1, 1-Dibromo-3-nitrilopropionamide 10222-01-2 30 0.00727 0
Polyethylene Glycol 25322-68-3 60 0.01455 0
Dibromoacetonitrile 3252-43-5 5 0.00121 0
Proppant Chevron Applachia, LLC Proppant Crystalline Silica 14808-60-7 100 6.39 0
WG-36 Halliburton Water Viscosifier Guar Gum 9000-30-0 100 0.00186 0
FR-66 Halliburton Friction Reducer Hydrotreated Light Distillite 64742-47-8 30 0.03285 0
7.5% Hcl Acid Reagent/PPG Used to open perfs Hydrochloric Acid 7647-01-0 7.5 0.28028 0
ASP 900 Nalco Friction Reducer Ammonium Sulfate 7783-20-2 30
EC6486A Nalco Scale Inhibitor Ethylene Glycol 107-21-1 30 0.00668 0
EC6673W Nalco Iron Control Ethylene Glycol 107-21-1 30 0.00687 0
Clean Volume Chevron Applachia, LLC Carrier/Base Fluid H20 7732-18-5 100 93.61 0

For data sources see[5]

Stimulation Data

Stimulation Date Phase Number Chemical Agent Volume (gal) Treating Pressure (psi) Breakdown Pressure (psi)
2013-03-22 0 0 0

For data sources see[6]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2011 CHEVRON APPALACHIA LLC 0.00 0 0.00 0 0.00 0
2012 CHEVRON APPALACHIA LLC 0.00 0 0.00 0 0.00 0
2013 CHEVRON APPALACHIA LLC 378,783.00 149 0.00 0 0.00 0
2014 CHEVRON APPALACHIA LLC 729,585.00 365 0.00 0 10.84 184
2015 CHEVRON APPALACHIA LLC 489,184.00 365 0.00 0 0.00 0
2016 CHEVRON APPALACHIA LLC 381,799.00 366 0.00 0 0.00 0
2017 CHEVRON APPALACHIA LLC 329,460.00 365 0.00 0 0.00 0
2018 CHEVRON APPALACHIA LLC 273,866.00 365 0.00 0 0.00 0
2019 CHEVRON APPALACHIA LLC 246,669.00 365 0.00 0 0.00 0

For data sources see[7]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2012 CHEVRON APPALACHIA LLC Drilling Fluid Waste 623.00 Bbl REUSE OTHER THAN ROAD SPREADING
2012 CHEVRON APPALACHIA LLC Drill Cuttings 1,067.64 Tons LANDFILL 100419
2012 CHEVRON APPALACHIA LLC Drilling Fluid Waste 2,525.70 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW001
2013 CHEVRON APPALACHIA LLC Fracing Fluid Waste 3,692.40 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW001
2013 CHEVRON APPALACHIA LLC Fracturing Fluid Waste 32.45 Tons LANDFILL 073 114 654
2013 CHEVRON APPALACHIA LLC Produced Fluid 1,435.00 Bbl REUSE OTHER THAN ROAD SPREADING
2013 CHEVRON APPALACHIA LLC Fracing Fluid Waste 3,839.90 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW001
2013 CHEVRON APPALACHIA LLC Fracing Fluid Waste 10,096.50 Bbl REUSE OTHER THAN ROAD SPREADING
2013 CHEVRON APPALACHIA LLC Produced Fluid 15.00 Bbl INJECTION DISPOSAL WELL 34-121-23995
2013 CHEVRON APPALACHIA LLC Drill Cuttings 0.65 Tons LANDFILL 100419
2014 CHEVRON APPALACHIA LLC Drill Cuttings 0.34 Tons LANDFILL 100419
2014 CHEVRON APPALACHIA LLC Produced Fluid 24.16 Bbl INJECTION DISPOSAL WELL 34-121-23995
2014 CHEVRON APPALACHIA LLC Fracturing Fluid Waste 22.19 Tons LANDFILL 100172
2014 CHEVRON APPALACHIA LLC Fracing Fluid Waste 74.83 Bbl REUSE OTHER THAN ROAD SPREADING
2014 CHEVRON APPALACHIA LLC Produced Fluid 3,277.67 Bbl REUSE OTHER THAN ROAD SPREADING
2015 CHEVRON APPALACHIA LLC Produced Fluid 1,015.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016 CHEVRON APPALACHIA LLC Produced Fluid 532.69 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW019
2016 CHEVRON APPALACHIA LLC Produced Fluid 573.01 Bbl REUSE OTHER THAN ROAD SPREADING
2017 CHEVRON APPALACHIA LLC Produced Fluid 2,350.17 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW001
2017 CHEVRON APPALACHIA LLC Produced Fluid 109.18 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2017 CHEVRON APPALACHIA LLC Produced Fluid 299.02 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2017 CHEVRON APPALACHIA LLC Produced Fluid 18.67 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2017 CHEVRON APPALACHIA LLC Drilling Fluid Waste 18.33 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2017 CHEVRON APPALACHIA LLC Produced Fluid 190.00 Bbl REUSE (AT WELL PAD)
2018 CHEVRON APPALACHIA LLC Produced Fluid 248.15 Bbl REUSE (AT WELL PAD)
2018 CHEVRON APPALACHIA LLC Produced Fluid 516.17 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018 CHEVRON APPALACHIA LLC Produced Fluid 20.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2019 CHEVRON APPALACHIA LLC Produced Fluid 20.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2019 CHEVRON APPALACHIA LLC Produced Fluid 358.34 Bbl REUSE (AT WELL PAD)
2019 CHEVRON APPALACHIA LLC Produced Fluid 21.67 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA

For data sources see[8]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2066603 Primary Facility 2012-04-23 Drilling/Alteration No Violations Noted HORIZONTAL MARCELLUS,HIGHLANDS # 7 MOVING ONTO HARTLEY # 10 - H TODAY (4/21/2012) .START DRILLING (4/22/2012) (TD) RUNNING WATER PROTECTION CASING @ 422' TONIGHT.RUNNING WATER PROTECTION CASING AND CEMENTING TONIGHT.
2066607 Primary Facility 2012-04-24 Drilling/Alteration No Violations Noted HORIZONTAL MARCELLUS, HIGHLANDS # 7 DRILLING ON AIR @ 644' TODAY. JUST DRILLING INTO COAL SEAM.
2066612 Primary Facility 2012-04-25 Drilling/Alteration No Violations Noted HORIZONTAL MARCELLUS, HIGHLANDS # 7 DRILLING ON AIR @ 705' (TD).RUNNING COAL PROTECTION CASING AND CEMENTING TONIGHT.
2071949 Primary Facility 2012-05-14 Drilling/Alteration No Violations Noted HORIZONTAL MARCELLUS, HIGHLANDS # 7 DRILLING ON AIR @ 7500', SET BRIDGE PLUG AND LOADED HOLE WITH OIL BASE MUD. CAPPED AND MOVE TO # 8 ON SAME PAD.
2071955 Primary Facility 2012-05-11 Drilling/Alteration No Violations Noted HORIZONTAL MARCELLUS,HIGHLANDS # 7 DRILLING ON AIR @ 7000' TODAY.
2071960 Primary Facility 2012-05-03 Drilling/Alteration No Violations Noted HORIZONTAL MARCELLUS, HIGHLANDS # 7 DRILLING ON AIR @ 2568' (TD).RUNNING INTERMEDIATE CASING AND CEMENTING TONIGHT.
2089939 Primary Facility 2012-08-08 Routine/Complete Inspection No Violations Noted ID sign legible and in place, E&S plan & PPC plan in mailbox, E&S controls in place and working, Patterson drill rig being set up at site
2094163 Primary Facility 2012-08-22 Drilling/Alteration No Violations Noted HORIZONTAL MAECELLUS , PATTERSON # 334 DRILLING ON FLUID @ 8605' TODAY.
2103226 Primary Facility 2012-08-24 Drilling/Alteration No Violations Noted HORIZONTAL MARCELLUS, PATTERSON # 334 DRILLING ON FLUID @ 12,565' (TD). RUNNING 51/2" PROD. CASING AND CEMENTING TODAY.
2129334 Primary Facility 2013-01-09 Routine/Complete Inspection No Violations Noted Sign up, PPC, permit, and E&S in box. Access road in good shape but icy. E&S controls in place and functioning. Operator told to keep eye on pits for freeboard minimums.
2184968 Primary Facility 2013-07-18 Site Restoration No Violations Noted Restoration extension date requested . Area stable, good vegetative growth, request approved until the new 12/25/14. date.
2209923 Primary Facility 2013-10-03 Routine/Complete Inspection No Violations Noted Act 9 sign up, plans and permits in box, upper pit being reclaimed, Tetra doing flowback activity, Pit 2 still in place and being drawn down, site stable.
2249483 Primary Facility 2014-02-27 Routine/Complete Inspection No Violations Noted On 2/27/2014, the Department conducted an inspection at Chevron Appalachia's Hartley Well Unit 6, 7, 8, 9, 10, 11H site in German Twp., Fayette County.
2510253 Primary Facility 2016-06-24 Routine/Complete Inspection No Violations Noted

On 06/24/16 at approximately 1300 hours I conducted a CEI for the Hartley Unit. The Act 9 sign was in place and all required documents were present at the site. Along the access road were small locations that were poorly vegetated (see photographs). It is recommended that these areas be addressed.

On 03/09/12 the Department received a complaint alleging run off from the site was impacting a privately owned pond. On 03/14/12 Department staff conducted an inspection of the site and found the violations listed below.

Violations of permit conditions 2, 7, 8, 18 25 Pa Code: 78.12, 102.11(a), 102.22(a)(1), 102.4(b), 78.53

A search of eFacts showed a record for 102.11, but the above violations were cited in the inspection report from 03/14/12.

At the time of inspection the site was stabilized with the exception of the aforementioned locations along the access road and there were no signs of erosion and sedimentation. There were no violations observed at the time of inspection.

2658254 Primary Facility 2017-11-02 Routine/Partial Inspection No Violations Noted The Act 9 sign was in place and all required documents were present at the site. The purpose of the inspection was to meet with BA Lambie of Chevron to discuss vegetation on a steep slope at the site entrance. Due to the steep slope and what appeared to be animal activity small bare spots were present. After discussing the issue Chevron determined they would consider options of adding additional soil, seeding, and mulching.
2843237 Primary Facility 2019-02-22 Routine/Complete Inspection No Violations Noted This well is tagged and in production. The well head casing, piping, production set equipment, containment dike and tank battery look ok.

For data sources see[9]

References