X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-051-24413

Well Details

Well ID: 37-051-24413
Loading map...
Country: United States
State: Pennsylvania
County: Fayette
Municipality: German Township
Operator Name: CHEVRON APPALACHIA LLC
Well Pad ID: 148321
Farm/Lease Name: FDS UNIT 8H
License Status:
Spud Date:
Permit Date: 2010-12-29
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: Yes
Latitude: 39.911189
Longitude: -79.911297

For data sources see[1][2][3]

Well History

Date Event
2010-12-29 New Permit Application
2011-06-08 Performed Spud Operation
2011-08-06 Drilling Completion
2011-10-14 Drilling Completion
2012-02-21 Perforation
2012-02-21 Performed Stimulation
2016-04-12 DEVIATED
2016-04-12 NEWLY DRILLED

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2012-03-06 2012-03-06 7,650 2,985,671

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 GBW-30 BREAKER Halliburton Energy Services Gel Breaker Carbohydrates 95.00 0.00010000
Hemicellulase enzyme 9012-54-8 15.00 0.00002000
EC6486A Nalco Scale Inhibitor Ethylene glycol 107-21-1 30.00 0.00727000
Biocide EC 6116A Nalco Biocide Polyethylene glycol 25322-68-3 60.00 0.01
2,2-Dibromo-3-nitrilopropionamide 10222-01-2 30.00 0.00736000
Dibromoacetonitrile 3252-43-5 5.00 0.00123000
ASP 900 Nalco Friction Reducer Ammonium sulfate 7783-20-2 30.00
FR-66 Friction Reducer Halliburton Energy Services Friction Reducer Distillates, petroleum, hydrotreated light 64742-47-8 30.00 0.03
7.5 Hcl Acid Used to open perfs Hydrochloric acid 7647-01-0 7.50 0.32
Proppant (lbs) Proppant 9.24 10.17
EC6673W Nalco Iron Control Ethylene glycol 107-21-1 30.00 0.00679000
Clean Volume (gals) Carrier/Base Fluid 90.76 100.00
WG-36 GELLING AGENT Halliburton Energy Services Water Viscosifier Guar gum 9000-30-0 100.00 0.00315000

For data sources see[5]

Stimulation Data

Stimulation Date Phase Number Chemical Agent Volume (gal) Treating Pressure (psi) Breakdown Pressure (psi)
2012-02-21 0 0 0

For data sources see[6]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2010 ATLAS RESOURCES LLC 0.00 0 0.00 0 0.00 0
2011 CHEVRON APPALACHIA LLC 0.00 0 0.00 0 0.00 0
2012 CHEVRON APPALACHIA LLC 469,049.00 276 0.00 0 0.00 0
2013 CHEVRON APPALACHIA LLC 419,237.00 365 0.00 0 0.00 0
2014 CHEVRON APPALACHIA LLC 294,463.00 334 0.00 0 0.00 0
2015 CHEVRON APPALACHIA LLC 219,383.00 365 0.00 0 0.00 0
2016 CHEVRON APPALACHIA LLC 189,504.00 366 0.00 0 0.00 0
2017 CHEVRON APPALACHIA LLC 165,443.00 365 0.00 0 0.00 0
2018 CHEVRON APPALACHIA LLC 142,799.00 365 0.00 0 0.00 0
2019 CHEVRON APPALACHIA LLC 126,682.00 365 0.00 0 0.00 0

For data sources see[7]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2011 CHEVRON APPALACHIA LLC Drilling Fluid Waste 2,017.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW001
2012 CHEVRON APPALACHIA LLC Fracturing Fluid Waste 65.01 Tons LANDFILL 100172
2012 CHEVRON APPALACHIA LLC Fracing Fluid Waste 15,198.40 Bbl REUSE OTHER THAN ROAD SPREADING
2012 CHEVRON APPALACHIA LLC Produced Fluid 2,648.00 Bbl REUSE OTHER THAN ROAD SPREADING
2012 CHEVRON APPALACHIA LLC Produced Fluid 285.00 Bbl INJECTION DISPOSAL WELL 34-121-23995
2012 CHEVRON APPALACHIA LLC Drilling Fluid Waste 915.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW001
2012 CHEVRON APPALACHIA LLC Fracing Fluid Waste 2,196.50 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW001
2013 CHEVRON APPALACHIA LLC Produced Fluid 1,030.00 Bbl REUSE OTHER THAN ROAD SPREADING
2014 CHEVRON APPALACHIA LLC Produced Fluid 889.33 Bbl REUSE OTHER THAN ROAD SPREADING
2015 CHEVRON APPALACHIA LLC Produced Fluid 538.33 Bbl REUSE OTHER THAN ROAD SPREADING
2016 CHEVRON APPALACHIA LLC Produced Fluid 318.33 Bbl REUSE OTHER THAN ROAD SPREADING
2016 CHEVRON APPALACHIA LLC Produced Fluid 181.01 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW019
2017 CHEVRON APPALACHIA LLC Produced Fluid 227.47 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2017 CHEVRON APPALACHIA LLC Produced Fluid 90.00 Bbl REUSE (AT WELL PAD)
2018 CHEVRON APPALACHIA LLC Produced Fluid 144.34 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018 CHEVRON APPALACHIA LLC Produced Fluid 70.00 Bbl REUSE (AT WELL PAD)
2019 CHEVRON APPALACHIA LLC Produced Fluid 236.67 Bbl REUSE (AT WELL PAD)

For data sources see[8]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1970337 Primary Facility 2011-05-04 Routine/Complete Inspection No Violations Noted
1979143 Primary Facility 2011-06-09 Routine/Complete Inspection No Violations Noted
1989870 Primary Facility 2011-07-21 Routine/Complete Inspection No Violations Noted
2004947 Primary Facility 2011-07-11 Drilling/Alteration No Violations Noted HORIZONTAL MARCELLUS,E&S & PITS IN GOOD CONDITION.CEMENTING WATER PROTECTION CASING TODAY.
2004950 Primary Facility 2011-07-12 Drilling/Alteration No Violations Noted HORIZONTAL MARCELLUS, E&S & PITS LOOK IN GOOD CONDITION. YOST #5 DRILLING ON AIR @ 810'. COAL SEAM @ 741' -744' .
2004952 Primary Facility 2011-07-14 Drilling/Alteration No Violations Noted HORIZONTAL MARCELLUS,E&S & PITS IN GOOD CONDITION. YOST # 5 DRILLING ON AIR @ 827' TODAY. CEMENTING COAL PROTECTION CASING @ 827' TODAY.BASKET SET @ 712' ON 113/4" CASING.
2004954 Primary Facility 2011-07-21 Drilling/Alteration No Violations Noted HORIZONTAL MARCELLUS, E&S & PITS IN GOOD CONDITION. YOST # 5 DRILLING ON AIR @ 2901' TODAY. CEMENTING INTERMEDIATE CASING TONIGHT @ 2901'.
2005145 Primary Facility 2011-07-29 Drilling/Alteration No Violations Noted HORIZONTAL MARCELLUS, E&S & PITS LOOK IN GOOD CONDITION. RIG MOVING OVER TO FDS 7 - H.
2009772 Primary Facility 2011-10-07 Drilling/Alteration No Violations Noted HORIZONTAL MARCELLUS, DRILLING ON FLUID @ 7593' IN CURVE PORTION OF WELL.
2015205 Primary Facility 2011-10-17 Drilling/Alteration No Violations Noted HORIZONTAL MARCELLUS. DRILLING ON FLUID @ 11,791' (TD) RUNNING 51/2" PROD. CASING AND CEMENTING TONIGHT.
2104927 Primary Facility 2012-09-26 Site Restoration No Violations Noted Site restoration extension request approved for 12 months, due 8/19/2013. Site being reclaimed at this time and E&S controls functioning.
2139716 Primary Facility 2013-02-14 Routine/Complete Inspection No Violations Noted Site Id sign in place, E&S plan in box, site gated, site has been reclaimed and is starting to grow vegetation. Site has a restoration extension. Some quad activity has been seen on site.
2180990 Primary Facility 2013-07-03 Site Restoration No Violations Noted Area has been reclaimed and has 70% cover. Landowner wants some additional work done that will disturb already reclaimed area. Department aware of landowner issue and is acceptable of the work to be done in the already reclaimed area.
2209904 Primary Facility 2013-10-03 Routine/Complete Inspection No Violations Noted Wells labeled, tanks in containment, old sox area at toe of slope vegetative growth is lacking, operator made aware.
2231148 Primary Facility 2013-12-19 Routine/Complete Inspection No Violations Noted On 12/19/2013 a the Department conducted an inspection of the FDS 6 H, 7H and 8 H Wells operated by Chevron Appalachia. The site is located in German Township, Fayette County.
2488213 Primary Facility 2016-05-20 Routine/Complete Inspection No Violations Noted HORIZONTAL MARCELLUS, Routine Inspection all looks good.
2572974 Primary Facility 2017-03-20 Routine/Complete Inspection No Violations Noted The Act 9 sign was in place and all required documents were present at the site. The site was well vegetated and there were no signs of erosion observed. The production equipment appeared to be in good condition. There were no violations observed at the time of inspection.

For data sources see[9]

References