Well Details

Well ID: 37-051-22199
Loading map...
Country: United States
State: Pennsylvania
County: Fayette
Municipality: Wharton Township
Operator Name: ALLIANCE PETRO CO LLC
Well Pad ID:
Farm/Lease Name: EAST SUMMIT
License Status: Plugged and Abandoned
Spud Date: 2004-07-28
Permit Date: 2004-07-15
Well Type: GAS
Unconventional Well: N
Configuration: Vertical Well
Conservation: No
Latitude: 39.792547
Longitude: -79.673057

For data sources see[1][2][3]

Well History

Date Event
2004-07-15 New Permit Application
2004-07-28 Performed Spud Operation
2004-09-23 Drilling Completion
2004-10-19 Perforation
2004-10-29 Performed Stimulation
2005-02-24 DEVIATED
2018-09-13 Begin Plugging
2018-11-20 Finished Plugging
2019-08-09 Fully Plugged

For data sources see[4]

Stimulation Data

Stimulation Date Phase Number Chemical Agent Volume (gal) Treating Pressure (psi) Breakdown Pressure (psi)
2004-10-29 0 0 0

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2005 CONSOL GAS CO 102919 365 0.00 0 0.00 0
2006 CONSOL GAS CO 101589.00 365 0.00 0 0.00 0
2007 CONSOL GAS CO 45324.00 365 0.00 0 0.00 0
2008 CONSOL GAS CO 8228.00 365 0.00 0 0.00 0
2009 CONSOL GAS CO 618.00 365 0.00 0 0.00 0
2010 CONSOL GAS CO 5,882.00 365 0.00 0 0.00 0
2011 CONSOL GAS CO 0.00 0 0.00 0 0.00 0
2012 CNX GAS CO LLC 1.00 366 0.00 0 0.00 0
2013 CNX GAS CO LLC 0.00 0 0.00 0 0.00 0
2014 CNX GAS CO LLC 0.00 0 0.00 0 0.00 0
2015 CNX GAS CO LLC 0.00 0 0.00 0 0.00 0
2016 CNX GAS CO LLC 0.00 0 0.00 0 0.00 0
2017 CNX GAS CO LLC 0.00 0 0.00 0 0.00 0
2018 CNX GAS CO LLC 0.00 0 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2005 CONSOL GAS CO Brine 5,517.00 Bbl Brine or Industrial Waste Treatment Plt PA0026034
2005 CONSOL GAS CO Brine 1,741.00 Bbl Injection Disposal Well 5690201
2008 CONSOL GAS CO Brine 3,922.21 Bbl Injection Disposal Well PAS2D912BSOM
2008 CONSOL GAS CO Brine 1,844.21 Bbl Other
2008 CONSOL GAS CO Brine 2,199.10 Bbl Brine or Industrial Waste Treatment Plt PA0026034
2009 CONSOL GAS CO Brine 184.00 Bbl Injection Disposal Well 5690201
2010 CONSOL GAS CO Produced Fluid 829.00 Bbl Injection Disposal Well PAS2D912BSOM
2010 CONSOL GAS CO Produced Fluid 3,901.86 Bbl PUBLIC SEWAGE TREATMENT PLANT PA0026034
2011 CNX GAS CO LLC Produced Fluid 276.00 Bbl PUBLIC SEWAGE TREATMENT PLANT PA0026034
2011 CNX GAS CO LLC Produced Fluid 2,200.97 Bbl REUSE OTHER THAN ROAD SPREADING
2014 CNX GAS CO LLC Produced Fluid 9.00 Bbl Injection Disposal Well 34-155-23203
2014 CNX GAS CO LLC Produced Fluid 9.00 Bbl Injection Disposal Well 34-155-21893
2014 CNX GAS CO LLC Produced Fluid 9.00 Bbl Injection Disposal Well 34-155-21894
2018 CNX GAS CO LLC Produced Fluid 360.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0254185

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1404114 Primary Facility 2004-12-21 Routine/Complete Inspection No Violations Noted Checked bench loc., drilled, pits closed, ditching w/sed. traps, sed. fence set, mulched over, topsoil still piled appears final phase not yet done, ID/plan at entrance. Moderate slope.
1825773 Primary Facility 2009-09-03 Routine/Complete Inspection No Violations Noted
1894503 Primary Facility 2010-06-25 Routine/Complete Inspection No Violations Noted
1933023 Primary Facility 2010-11-09 Complaint Inspection Violation(s) Noted
1941049 Primary Facility 2011-01-06 Routine/Complete Inspection No Violations Noted Pumpjack operating. 2 tanks onsite. Tag and e&s ok.
1943986 Primary Facility 2011-01-19 Routine/Complete Inspection Outstanding Violations - No Viols Req'd WQS Carey Vallor and Myself went out to the East Summit well site to do a routine inspection on the well site and to see if any actions have yet been taken on the cleanup (soils removal) of the spill reported and NOV issued. No work has been done yet to correct the spill, but, no further violations were seen.
1958173 Primary Facility 2011-03-17 Routine/Complete Inspection Outstanding Violations - No Viols Req'd
1965000 Primary Facility 2011-03-18 Routine/Partial Inspection Outstanding Violations - No Viols Req'd Follow-up from inspection of March 17 to check work. No problems found.
1980359 Primary Facility 2011-06-09 Routine/Complete Inspection No Violations Noted Pumpjack on well. 3 tanks onsite. Tag and e&s ok.
1989574 Primary Facility 2011-07-05 Compliance Evaluation No Violations Noted
2212605 Primary Facility 2013-10-11 Routine/Complete Inspection No Violations Noted Site ID sign on site, two tanks in containment, no leaks or E&S issues observed.
2381133 Primary Facility 2015-06-19 Routine/Complete Inspection No Violations Noted Pumpjack and tanks removed from site. Tag and e&s ok.
2478679 Primary Facility 2016-04-19 Routine/Complete Inspection No Violations Noted Routine Inspection for In-Active Status denied. All equipment has been removed from location.
2480268 Primary Facility 2016-05-03 Follow-up Inspection Violation(s) Noted Upon investigation of Inactive Status and Inspection on site,this well appears to be "Abandoned" since 2013. No production reported to Pa. DEP Oil & GAS Reporting System since 2013. § 3203. 78.91. General provisions (a) Upon abandoning a well, the owner or operator shall plug the well under § § 78.92—78.98 or an approved alternate method under section 211 of the act(58 P. S. § 601.211) to stop the vertical flow of fluids or gas within the well bore.

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
1933023 601005 11/09/2010 2010-11-09 78.54* - Failure to properly control or dispose of industrial or residual waste to prevent pollution of the waters of the Commonwealth. Environmental Health & Safety Operator failed to properly collect and store production fluids which resulted in a residual waste (flowback) discharge to the ground. The flowback was released due to a failure in the flow line. 78.54 and 78.57 (a).
1933023 601006 11/09/2010 2010-11-09 6018.301 - Residual Waste is mismanaged. Environmental Health & Safety Operator improperly disposed flowback water to the ground and into the waters of the Commonwealth. 35 PS 6018.301, 302 (a).
1933023 601007 11/09/2010 2010-11-09 301CSL - Stream discharge of IW, includes drill cuttings, oil, brine and/or silt Environmental Health & Safety Operator improperly disposed industrial waste (flowback water) to the waters of the Commonwealth (2 springs impacted). CSL 301, 401, 307.
2480268 758295 2016-05-03 78.91(a) Environmental Health & Safety

Penalties Applied

Violation ID Penalty ID Penalty Code Penalty Status Penalty Date Enforcement Date Penalty Amount Amount Collected
601005 265612 NOV - Notice of Violation Comply/Closed 2011-07-05
601005 275477 CACP - Consent Assessment of Civil Penalty Comply/Closed 2011-10-03 2011-10-03 $6,750.00 $6,750.00
601006 265612 NOV - Notice of Violation Comply/Closed 2011-07-05
601006 275477 CACP - Consent Assessment of Civil Penalty Comply/Closed 2011-10-03 2011-10-03 $6,750.00 $6,750.00
601007 265612 NOV - Notice of Violation Comply/Closed 2011-07-05
601007 275477 CACP - Consent Assessment of Civil Penalty Comply/Closed 2011-10-03 2011-10-03 $6,750.00 $6,750.00
758295 342448 NOV - Notice of Violation 2018-05-31
758295 364523 CMPOR - Compliance Order

For data sources see[8]