If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-051-21013 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.022269,"lon":-79.633041,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Fayette | |
Municipality: Dunbar Township | |
Operator Name: KEYROCK ENERGY LLC | |
Well Pad ID: | |
Farm/Lease Name: G HARVEY USX 4 | |
License Status: ACTIVE | |
Spud Date: 1998-09-28 | |
Permit Date: 1998-07-24 | |
Well Type: COALBED METHANE | |
Unconventional Well: N | |
Configuration: Vertical Well | |
Conservation: No | |
Latitude: 40.022269 | |
Longitude: -79.633041 |
Date | Event |
---|---|
1998-07-24 | New Permit Application |
1998-09-28 | Performed Spud Operation |
1998-09-29 | Drilling Completion |
1998-10-16 | Perforation |
1998-10-16 | Performed Stimulation |
2000-02-18 | NEWLY DRILLED |
For data sources see[4]
Stimulation Date | Phase Number | Chemical Agent | Volume (gal) | Treating Pressure (psi) | Breakdown Pressure (psi) |
---|---|---|---|---|---|
1998-10-16 | 0 | 0 | 0 |
For data sources see[5]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
1999 | BELDEN & BLAKE CORP | 3847 | 308 | 0.00 | 0 | 0.00 | 0 |
2000 | BELDEN & BLAKE CORP | 5069 | 366 | 0.00 | 0 | 0.00 | 0 |
2001 | BELDEN & BLAKE CORP | 3018 | 365 | 0.00 | 0 | 0.00 | 0 |
2002 | BELDEN & BLAKE CORP | 2592 | 365 | 0 | 0 | 0.00 | 0 |
2003 | BELDEN & BLAKE CORP | 1444 | 365 | 0.00 | 0 | 0.00 | 0 |
2004 | BELDEN & BLAKE CORP | 3001 | 366 | 0.00 | 0 | 0.00 | 0 |
2005 | BELDEN & BLAKE CORP | 2775 | 365 | 0 | 365 | 0.00 | 0 |
2006 | BELDEN & BLAKE CORP | 2470.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2007 | BELDEN & BLAKE CORP | 2,907.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2008 | BELDEN & BLAKE CORP | 4,075.21 | 366 | 0.00 | 0 | 0.00 | 0 |
2009 | BELDEN & BLAKE CORP | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2010 | KEYROCK ENERGY LLC | 1,422.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2011 | KEYROCK ENERGY LLC | 796.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2012 | KEYROCK ENERGY LLC | 317.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2013 | KEYROCK ENERGY LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2014 | KEYROCK ENERGY LLC | 1.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2015 | KEYROCK ENERGY LLC | 591.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2016 | KEYROCK ENERGY LLC | 851.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2018 | KEYROCK ENERGY LLC | 166.00 | 365 | 0.00 | 0 | 0.00 | 0 |
For data sources see[6]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2002 | BELDEN & BLAKE CORP | Brine | 403.00 Bbl | Treated On-Site, NPDES Discharge | |
2003 | BELDEN & BLAKE CORP | Brine | 467.00 Bbl | Treated On-Site, NPDES Discharge | PA0217778 |
2004 | BELDEN & BLAKE CORP | Brine | 179.79 Bbl | Treated On-Site, NPDES Discharge | PA0217778 |
2005 | BELDEN & BLAKE CORP | Brine | 84.00 Bbl | Treated On-Site, NPDES Discharge | PA0217778 |
2006 | BELDEN & BLAKE CORP | Brine | 9.00 Bbl | Treated On-Site, NPDES Discharge | PA0217778 |
For data sources see[7]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
1074762 | Primary Facility | 2001-11-07 | Routine/Complete Inspection | No Violations Noted | Gated access is at RT. 201. Well is on hillside above hollow, tagged. Site is below gaswell 20749. Pumpjack at well, shielding fence from cattle installed, meter, equip. working. Access stoned, stable along fence row. CBM well. |
2085687 | Primary Facility | 2012-06-01 | Complaint Inspection | Violation(s) Noted | THE G. HARVEY USX # 4 (COAL - BED METHANE WELL) WAS BEING SERVICED BY MAXIMUM WELL SERVICE DURING THE DATES OF 5/18/2012 TO 6/1/2012. ON 5/22/2012 MAXIMUM’S CREW ENCOUNTERED A RELEASE OF FLUIDS DURING OPERATIONS OF SAND PUMPING ON 4 1/2" CASING. THE SAND LINE SOCKET FAILED WHILE EMPTYING THE SAND PUMP. THE LUBRICATOR AND SAND PUMP FELL OVER A FENCE RELEASING FLUIDS ONTO THE GROUND. TWO RIG HANDS VERIFIED THIS ON 5/22/2012 AT 4:30 PM. KEYROCK FAILED TO CONTAIN POLLUTIONAL SUBSTANCES DURING THE OPERATION. THE DISCHARGE OBSERVED WAS A DIRECT VIOLATION OF 78.56. |
2087227 | Primary Facility | 2012-05-31 | Complaint Inspection | Pending | Inspection completed today in response to complaint of spill. Soil samples taken along with photos. |
2087230 | Primary Facility | 2012-07-05 | Complaint Inspection | Outstanding Violations - No Viols Req'd | Water samples taken at spring fed stream down slope of USX 4 well on concern from landowner. |
2087258 | Primary Facility | 2012-07-10 | Follow-up Inspection | Outstanding Violations - No Viols Req'd | Rick Lewis and I along with landowner and operator decided where opr. will take soil samples to clean up spill site. |
2343073 | Primary Facility | 2015-02-10 | Administrative/File Review | Outstanding Violations - No Viols Req'd | 02/05/15 |
2379753 | Primary Facility | 2015-05-20 | Routine/Complete Inspection | Outstanding Violations - No Viols Req'd | On 05/20/15 at approximately 1330 hours I along with OGI Rick LEWIS met with Keyrock Energy LLC representative Mike BUCHEIT to discuss the outstanding violations and site characterization at the G. Harvey USX 4 well site. The site was fenced and gated to exclude horses from accessing the area of the spill and the well. The site was vegetated, but exhibited spots of bare, slightly rocky soil and areas of what appeared to be iron staining on the soil surface near the well head. There was slight erosion occurring near the well head going down into the fenced area. One yellow flag showing a previous sampling location was found at the site. After discussing the characterization expectations due to the spill being three years old, BUCHEIT contacted ESL labs to schedule sampling for 05/22/15. |
2404483 | Primary Facility | 2015-08-31 | Administrative/File Review | Outstanding Violations - No Viols Req'd | Admin review of site characterization report from Silbaugh Hydrogeological Services. The report was insufficient for characterization of the spill. Additional sampling is required to characterize the site. Keyrock is requested to respond to the report by 09/17/15 |
2434308 | Primary Facility | 2015-12-03 | Administrative/File Review | Outstanding Violations - No Viols Req'd | WQSS John Carson, EGM Dan Counahan, and I met with Chris Shea of Keyrock Energy and David Silbaugh of Silbaugh Hydrogeological Services to discuss the Harvey USX #4. It was agreed that five samples will be taken as a site charcterization in response to a 2012 spill at the site. The samples will be analyzed for the brine suite found in DEP Program Program Clarification Memo and will be taken as follows: |
2731555 | Primary Facility | 2018-05-04 | Complaint Inspection | No Violations Noted | Well appears equipped for production. Well head surrounded by security fence.
At time of inspection Department observed a 10'X10' area lacking vegetation (photo #1). This area is approximately 688' from the well head. This area surrounds an approximately 16" deep hole (photo #2). It appears that air/gas is escaping from this hole. Department contacted operator by phone from site. Operator rep Mark arrived and stated their brine collection line runs through this area. Mark also stated a water line and another gas line are located near this area. Department contacted Diversified Oil and Gas Co due to their ownership of a well on this property. Diversified Rep arrived on site and shut in their well. This did not cause the air/gas to stop escaping from the hole. DEP WQS Cindy Witham contacted DEP OGI Rick Lewis. Mr. Lewis arrived on site and recorded a reading of 100% natural gas with a 62s meter. Department requests operator ensure area is safe, replace/repair line, and remediate area per current regulations |
2731584 | Primary Facility | 2018-05-08 | Administrative/File Review | No Violations Noted | ADMIN inspection to inspection record #2731555.
Operator rep Doug Wadsworth contacted Department by phone, left message. Department returned Mr. Wadsworth's call later that morning. Mr. Wadsworth stated the leaking line was fixed yesterday (5-7-18). Mr. Wadsworth stated he feels water company struck line when they were working in the area. Mr. Wadsworth stated the excavated area is backfilled, seeded, and mulched. A follow up inspection will be conducted at a later date. Violation(s) may be forthcoming pending future inspections. |
2731589 | Primary Facility | 2018-05-10 | Routine/Partial Inspection | No Violations Noted | Routine Partial Inspection to inspection record #2731555.
At time of inspection disturbed area appears to have been backfilled, seeded, and mulched. No leaking air/gas observed at this time. It appears the leaking line has been fixed. Inspection(s) will be conducted at a later date to ensure site is permanently stabilized. Violation(s) may be issued based on future inspection(s). |
2733869 | Primary Facility | 2018-05-04 | Administrative/File Review | Violation(s) Noted | ADMIN Inspection to inspection record #2731555. At the time of that inspection, it appears the buried line was compromised and air/gas was escaping.
Based on observations made in above mentioned inspection, a violation is being issued for venting of gas to the atmosphere that produced a hazard to the public health and safety. This inspection is being referred to OGI Supervisor for OGI follow up. |
2733911 | Primary Facility | 2018-05-08 | Compliance Evaluation | No Violations Noted | ADMIN Compliance Evaluation Inspection to inspection record #2733869.
According to inspection record #2731584, operator reported that the leaking line was fixed on 5-7-18. Based on observations recorded in inspection record #2731589 no leaking air/gas was observed and it appears the line has been fixed. The violation issued on 5-4-18 has been corrected and is closed. |
2734744 | Primary Facility | 2018-05-24 | Administrative/File Review | No Violations Noted | ADMIN Inspection to inspection record #2731555.
Department contacted operator rep Doug Wadsworth by phone. Department requested information about pipe lines located near area of no vegetation observed in above inspection. Mr. Wadsworth stated a municipal water line is located alongside the operators brine and gas lines. Mr. Wadsworth also stated that pictures were taken by him during the fixing of the pipe. Inspection(s) will be conducted at a later date to ensure site is permanently stabilized. Violation(s) may be issued based on future inspection(s). |
2736721 | Primary Facility | 2018-05-29 | Administrative/File Review | No Violations Noted | Operator rep Doug Wadsworth submitted photos of hole in pipe taken while replacing leaking pipe (photo #1 and 2). |
2738315 | Primary Facility | 2018-06-06 | Administrative/File Review | No Violations Noted | ADMIN inspection to document phone call by operator rep Michael Bucheit to Department. Mr. Bucheit requested clarification on what is required in the response to the NOV. Department addressed Mr. Bucheit's questions and concerns. |
2741294 | Primary Facility | 2018-06-13 | Administrative/File Review | No Violations Noted | Department received operator response to the NOV (photos #1-3) issued on 5-4-18 (inspection record #2733869). |
2742151 | Primary Facility | 2018-06-13 | Routine/Partial Inspection | In Compliance with Policy | At time of inspection site appears backfilled, seeded, and mulched. Vegetation growing but it does not appear that vegetation has reached >70% uniform vegetative growth (photo #1). Department recommends operator continue to monitor and maintain disturbed area to ensure permanent stabilization is reached. |
2752707 | Primary Facility | 2018-07-12 | Routine/Partial Inspection | No Violations Noted | RTPT inspection to evaluate vegetative growth on disturbed area along pipeline.
At time of inspection vegetation in previously disturbed area appears to have reached >70% uniform growth (photo #1). No E and S issues observed. Department recommends operator continue to monitor and maintain area to ensure vegetative growth is adequate and sustained. |
386498 | Primary Facility | 1998-12-23 | Routine/Complete Inspection | No Violations Noted | E&S ADEQUATE |
Inspection ID | Violation ID | Violation Date | Date Resolved | Violation Code | Violation Type | Violation Comments |
---|---|---|---|---|---|---|
2085687 | 644751 | 06/01/2012 | 2012-06-01 | 78.56(1) - Pit and tanks not constructed with sufficient capacity to contain pollutional substances. | Administrative | NO PIT OR TANK TO CATCH FLUIDS DURING OPERATIONS OF SERVICING WELL. |
2085687 | 644752 | 06/01/2012 | 2012-06-01 | 78.66BRINE - Failure to report a reportable release of brine to DEP within 2 hours. | Administrative | NO REPOTING OF BRINE RELEASE FROM SPILL ON SITE. |
2733869 | 817495 | 2018-05-04 | 2018-05-08 | 78.74 | Environmental Health & Safety |
Violation ID | Penalty ID | Penalty Code | Penalty Status | Penalty Date | Enforcement Date | Penalty Amount | Amount Collected |
---|---|---|---|---|---|---|---|
644751 | 304024 | NOV - Notice of Violation | |||||
644752 | 304024 | NOV - Notice of Violation | |||||
817495 | 364292 | NOV - Notice of Violation | 2018-07-26 |
For data sources see[8]