Well ID: 37-047-24793 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.588228,"lon":-78.428106,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Elk | |
Municipality: Jones Township | |
Operator Name: SENECA RESOURCES CO LLC | |
Well Pad ID: 151238 | |
Farm/Lease Name: SRC WT 2329 37H 51335 | |
License Status: | |
Spud Date: | |
Permit Date: 2013-12-17 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: No | |
Latitude: 41.588228 | |
Longitude: -78.428106 |
Date | Event |
---|---|
2013-12-17 | New Permit Application |
2014-04-27 | Performed Spud Operation |
2014-06-30 | Drilling Completion |
2014-11-07 | Perforation |
2015-03-30 | DEVIATED |
For data sources see[4]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2014-11-16 | 2014-11-30 | 6,078 | 8,439,230 | 0 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | Proppant 80/100 Oklahoma | Trican | Proppant | Silica | 14808-60-7 | 100 | 0.622987 | 0 |
Sl-7 | Trican | Scale Inhibitor | Ethylene glycol | 107-21-1 | 30 | 0.00792636 | 0 | |
Proppant 40/70 Ottawa | Trican | Proppant | Crystalline silica (quartz) | 14808-60-7 | 100 | 5.97101 | 0 | |
FR-15 | Trican | Friction Reducer | Proprietary Amide | Proprietary | 2.5 | 0.00175921 | 0 | |
Distillates (petroleum), Hydrotreated Light | 64742-47-8 | 25 | 0.0175921 | 0 | ||||
Water | Seneca Resources | Carrier/Base Fluid | Water | 7732-18-5 | 100 | 87.8256 | 0 | |
Proppant 30/50 Ottawa | Trican | Proppant | Crystalline silica (quartz) | 14808-60-7 | 100 | 5.51532 | 0 | |
7.5% HydroChloric Acid | Trican | Acid | Hydrochloric Acid HCl | 7647-01-0 | 7.5 | 0.0331343 | 0 | |
AL-7NR | Trican | Corrosion Inhibitor | Prop-2-yn-1-ol | 107-19-7 | 1 | 0.00000950 | 0 | |
MBC 516 | Trican | Biocide | Glutaraldehyde | 111-30-8 | 27 | 0.00256679 | 0 | |
N-alkyl dimethyl benzyl ammonium chloride | 68424-85-1 | 5.5 | 0.00052286 | 0 | ||||
Ethanol | 64-17-5 | 2.8 | 0.00026619 | 0 | ||||
Didecyl dimethyl ammonium chloride | 7173-51-5 | 8.3 | 0.00078905 | 0 | ||||
FEAC 20 | Trican | Iron Control | Acetic acid | 64-19-7 | 50 | 0.00033647 | 0 | |
Citric acid | 77-92-9 | 30 | 0.00020188 | 0 |
For data sources see[5]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2014 | SENECA RESOURCES CO LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2015 | SENECA RESOURCES CO LLC | 614,219.34 | 256 | 0.00 | 0 | 0.00 | 0 |
2016 | SENECA RESOURCES CO LLC | 457,804.65 | 326 | 0.00 | 0 | 0.00 | 0 |
2017 | SENECA RESOURCES CO LLC | 341,943.99 | 308 | 0.00 | 0 | 0.00 | 0 |
2018 | SENECA RESOURCES CO LLC | 303,004.55 | 364 | 0.00 | 0 | 0.00 | 0 |
2019 | SENECA RESOURCES CO LLC | 192,781.44 | 325 | 0.00 | 0 | 0.00 | 0 |
For data sources see[6]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2014 | SENECA RESOURCES CO LLC | Drill Cuttings | 1,102.84 Tons | LANDFILL | 101397 |
2015 | SENECA RESOURCES CO LLC | Produced Fluid | 12,416.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NW011 |
2015 | SENECA RESOURCES CO LLC | Basic Sediment | 49.57 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123 |
2015 | SENECA RESOURCES CO LLC | Fracing Fluid Waste | 438.57 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123 |
2015 | SENECA RESOURCES CO LLC | Servicing Fluid | 37.04 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123 |
2015 | SENECA RESOURCES CO LLC | Produced Fluid | 136.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NW005 |
2015 | SENECA RESOURCES CO LLC | Produced Fluid | 35,318.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016 | SENECA RESOURCES CO LLC | Other Oil & Gas Wastes | 22.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2016 | SENECA RESOURCES CO LLC | Produced Fluid | 2,220.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2016 | SENECA RESOURCES CO LLC | Servicing Fluid | 18.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NW011 |
2016 | SENECA RESOURCES CO LLC | Other Oil & Gas Wastes | 140.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NW011 |
2016 | SENECA RESOURCES CO LLC | Produced Fluid | 23.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW005 |
2016 | SENECA RESOURCES CO LLC | Produced Fluid | 24,293.75 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NW011 |
2016 | SENECA RESOURCES CO LLC | Produced Fluid | 211.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016 | SENECA RESOURCES CO LLC | Produced Fluid | 37.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NW005 |
2017 | SENECA RESOURCES CO LLC | Other Oil & Gas Wastes | 149.75 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2017 | SENECA RESOURCES CO LLC | Produced Fluid | 18,715.43 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2017 | SENECA RESOURCES CO LLC | Produced Fluid | 297.08 Bbl | REUSE (AT WELL PAD) | |
2018 | SENECA RESOURCES CO LLC | Produced Fluid | 11,269.50 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2018 | SENECA RESOURCES CO LLC | Produced Fluid | 164.50 Bbl | INJECTION DISPOSAL WELL | PAS2D025BELK |
2018 | SENECA RESOURCES CO LLC | Produced Fluid | 183.34 Bbl | REUSE (AT WELL PAD) | |
2018 | SENECA RESOURCES CO LLC | Other Oil & Gas Wastes | 55.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW005 |
2018 | SENECA RESOURCES CO LLC | Other Oil & Gas Wastes | 654.17 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2018 | SENECA RESOURCES CO LLC | Produced Fluid | 215.34 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW005 |
2019 | SENECA RESOURCES CO LLC | Other Oil & Gas Wastes | 219.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2019 | SENECA RESOURCES CO LLC | Synthetic Liner Materials | 4.76 Tons | LANDFILL | 100361 |
2019 | SENECA RESOURCES CO LLC | Produced Fluid | 12,854.84 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2019 | SENECA RESOURCES CO LLC | Other Oil & Gas Wastes | 12.22 Bbl | REUSE (AT WELL PAD) |
For data sources see[7]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2268250 | Primary Facility | 2014-05-05 | Administrative/File Review | No Violations Noted | |
2268284 | Primary Facility | 2014-04-30 | Drilling/Alteration | No Violations Noted | |
2286289 | Primary Facility | 2014-07-08 | Drilling/Alteration | No Violations Noted | |
2341886 | Primary Facility | 2015-02-09 | Administrative/File Review | No Violations Noted | |
2352986 | Primary Facility | 2015-03-19 | Administrative/File Review | No Violations Noted | |
2586121 | Primary Facility | 2017-04-21 | Routine/Complete Inspection | No Violations Noted | On 4/21/17 at 1139 hrs. I conducted a routine inspection of Seneca Resources' Clermont Pad D and associated wells. Well 51335 (API 047-24793) is equipped for production and has a well tag present. There are no violations noted for this inspection. |
2730204 | Primary Facility | 2018-05-15 | Routine/Complete Inspection | No Violations Noted | There are 6 active wells on this pad and 6 permitted wells that have not been drilled yet. No leaks detected and all wells are producing. |
For data sources see[8]