X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-035-20172

Well Details

Well ID: 37-035-20172
Loading map...
Country: United States
State: Pennsylvania
County: Clinton
Municipality: Leidy Township
Operator Name:
Well Pad ID:
Farm/Lease Name: HE FINNEFROCK LW 50
License Status: Plugged and Abandoned
Spud Date:
Permit Date: 1971-11-11
Well Type: STORAGE WELL
Unconventional Well: N
Configuration: Vertical Well
Conservation: No
Latitude: 41.429248
Longitude: -77.858925

For data sources see[1][2][3]

Well History

Date Event
1950-09-27 Performed Spud Operation
1951-02-02 Drilling Completion
1952-05-02 OLD WELL
1958-10-02 Perforation
1958-10-18 Drilling Completion
1959-05-02 CONVERTED TO STORAGE (GAS)
1970-03-24 Perforation
1970-03-28 Drilling Completion
1971-05-02 DRILLED DEEPER
1971-11-11 New Permit Application
2014-08-06 Finished Plugging

For data sources see[4]


Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2003 DOMINION ENERGY TRANS INC 0.00 0 0.00 0 0.00 0
2006 DOMINION ENERGY TRANS INC 0.00 0 0.00 0 0.00 0
2007 DOMINION ENERGY TRANS INC 0.00 0 0.00 0 0.00 0
2008 DOMINION ENERGY TRANS INC 0.00 0 0.00 0 0.00 0
2009 DOMINION ENERGY TRANS INC 0.00 0 0.00 0 0.00 0
2010 DOMINION ENERGY TRANS INC 0.00 0 0.00 0 0.00 0
2011 DOMINION ENERGY TRANS INC 0.00 0 0.00 0 0.00 0
2012 DOMINION ENERGY TRANS INC 0.00 0 0.00 0 0.00 0
2013 DOMINION ENERGY TRANS INC 0.00 0 0.00 0 0.00 0
2014 DOMINION ENERGY TRANS INC 0.00 0 0.00 0 0.00 0
2015 DOMINION ENERGY TRANS INC 0.00 0 0.00 0 0.00 0
2016 DOMINION ENERGY TRANS INC 0.00 0 0.00 0 0.00 0

For data sources see[5]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1067349 Primary Facility 2001-10-10 Routine/Complete Inspection No Violations Noted
1174099 Primary Facility 2002-09-30 Routine/Complete Inspection No Violations Noted
1280205 Primary Facility 2003-10-21 Routine/Complete Inspection No Violations Noted
1570167 Primary Facility 2006-10-02 Routine/Complete Inspection No Violations Noted
1661371 Primary Facility 2007-10-15 Routine/Complete Inspection No Violations Noted
1747582 Primary Facility 2008-10-30 Routine/Complete Inspection No Violations Noted
1839563 Primary Facility 2009-10-28 Routine/Complete Inspection No Violations Noted
2014902 Primary Facility 2011-10-13 Routine/Complete Inspection No Violations Noted
2229724 Primary Facility 2013-10-29 Routine/Complete Inspection No Violations Noted
2250000 Primary Facility 2014-02-25 Plugging(Includes Plugged/Mined Through) No Violations Noted
2254444 Primary Facility 2014-03-13 Plugging(Includes Plugged/Mined Through) No Violations Noted
2254447 Primary Facility 2014-03-17 Plugging(Includes Plugged/Mined Through) No Violations Noted
2254450 Primary Facility 2014-03-16 Plugging(Includes Plugged/Mined Through) No Violations Noted
2254453 Primary Facility 2014-03-14 Plugging(Includes Plugged/Mined Through) No Violations Noted
2256986 Primary Facility 2014-03-21 Plugging(Includes Plugged/Mined Through) No Violations Noted
2256989 Primary Facility 2014-03-24 Plugging(Includes Plugged/Mined Through) No Violations Noted
2256990 Primary Facility 2014-03-25 Plugging(Includes Plugged/Mined Through) No Violations Noted
2264805 Primary Facility 2014-04-03 Plugging(Includes Plugged/Mined Through) No Violations Noted
2265184 Primary Facility 2014-04-07 Plugging(Includes Plugged/Mined Through) No Violations Noted
2275260 Primary Facility 2014-05-30 Plugging(Includes Plugged/Mined Through) No Violations Noted
2292313 Primary Facility 2014-07-14 Plugging(Includes Plugged/Mined Through) No Violations Noted
2303613 Primary Facility 2014-09-10 Plugging(Includes Plugged/Mined Through) No Violations Noted
2317929 Primary Facility 2014-10-29 Plugging(Includes Plugged/Mined Through) No Violations Noted
2394084 Primary Facility 2015-07-21 Plugging(Includes Plugged/Mined Through) No Violations Noted At the time of inspection Overcast, ~ 78 degrees F.
2399186 Primary Facility 2015-08-10 Site Restoration No Violations Noted No ESCGP is associated with this well farm, site is <5 arces. Well was plugged April 7, 2014.
2416837 Primary Facility 2015-10-15 Plugging(Includes Plugged/Mined Through) No Violations Noted Inspection of plugged well. No Violations noted.
2509397 Primary Facility 2016-08-10 Plugging(Includes Plugged/Mined Through) No Violations Noted Inspection of Dominion’s H.E. Finnefrock LW-50 well in Leidy Twp., Clinton Co. conducted August 10, 2016 at approximately 12:50 pm. Records show the well was plugged in 2014. At the time of inspection: the well was covered with gravel with four 2” vent pipes coming out of the ground. The plugging certificate shows 4 ½” production casing was left in the hole, and the other 3 vents would be the (1) backside of 4 ½” production casing, (2) backside of 7” intermediate csg, and (3) backside of 9 5/8” csg. (plus the 4 ½” csg vent). None of the vents were labeled and there was no way to tell which annulus they were coming from since the well is buried. I did a gas check on all 4 vents with an Altair 5x multi-gas meter. Only one vent had gas; the vent on the far right if you’re facing the permit sign showed 100% methane. A Dominion employee pulled up at this time. He said he didn’t know which vent was which but would run back to the station and e-mail me a picture with the vents labeled. The picture showed the vent w
2563361 Primary Facility 2017-02-21 Plugging(Includes Plugged/Mined Through) No Violations Noted Inspection of Dominion’s H.E. Finnefrock LW-50 well in Leidy Twp., Clinton Co. conducted February 21, 2017 at 12:00 pm. The LW 50 was plugged in 2014. At the time of inspection; the well was buried and had (4) 2” vent pipes plumbed to surface for wellbore and each annulus. At the time of inspection; 3 of the 4 vent pipes had no gas, and the 1 that had gas was labeled by the operator as being the 13x9” annulus which showed 4% methane inside the vent at the time of inspection, down considerably since last inspection in August. The vent pipe had a threaded 2” 90deg fitting; I hooked up directly and conducted balloon test; there was no measurable/significant flow observed, thus meeting plugging requirements of 78.91 with regard to measurable flow. Plugging certificate signed and sent to file.
2656554 Primary Facility 2017-10-30 Routine/Complete Inspection No Violations Noted
355208 Primary Facility 1988-10-05 Routine/Complete Inspection No Violations Noted
355209 Primary Facility 1989-10-10 Routine/Complete Inspection No Violations Noted
367067 Primary Facility 1990-10-10 Routine/Complete Inspection No Violations Noted
369820 Primary Facility 1991-10-09 Routine/Complete Inspection No Violations Noted
372668 Primary Facility 1992-10-27 Routine/Complete Inspection No Violations Noted
374641 Primary Facility 1993-10-05 Routine/Complete Inspection No Violations Noted
376717 Primary Facility 1994-10-12 Routine/Complete Inspection No Violations Noted
379155 Primary Facility 1995-10-16 Routine/Complete Inspection No Violations Noted
381007 Primary Facility 1996-10-16 Routine/Complete Inspection No Violations Noted
383451 Primary Facility 1997-10-06 Routine/Complete Inspection No Violations Noted
385926 Primary Facility 1998-10-05 Routine/Complete Inspection No Violations Noted
881252 Primary Facility 1999-10-05 Routine/Complete Inspection No Violations Noted
975392 Primary Facility 2000-10-17 Routine/Complete Inspection No Violations Noted

For data sources see[6]

References