37-033-23420

Well Details

Well ID: 37-033-23420
Loading map...
Country: United States
State: Pennsylvania
County: Clearfield
Municipality: Bell Township
Operator Name: FAIRMAN CORP
Well Pad ID:
Farm/Lease Name: CARL E. HARKLEROAD
License Status: Plugged and Abandoned
Spud Date: 1992-07-02
Permit Date: 1992-05-15
Well Type: GAS
Unconventional Well: N
Configuration: Vertical Well
Conservation: No
Latitude: 40.896368
Longitude: -78.804141

For data sources see[1][2][3]

Well History

Date Event
1992-05-15 New Permit Application
1992-07-02 Performed Spud Operation
1992-07-07 Drilling Completion
1992-07-15 Perforation
1992-10-26 NEWLY DRILLED
2017-05-15 Begin Plugging
2018-09-11 Finished Plugging
2019-02-26 Fully Plugged

For data sources see[4]


Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
1993 FAIRMAN DRILLING CO 3130.00 306 0.00 0 0.00 0
1994 FAIRMAN DRILLING CO 2193.00 365 0.00 0 0.00 0
1996 FAIRMAN DRILLING CO 3519 365 0.00 0 0.00 0
1997 FAIRMAN DRILLING CO 2626 365 0.00 0 0.00 0
1998 FAIRMAN DRILLING CO 4257 365 0.00 0 0.00 0
1999 FAIRMAN DRILLING CO 2479 365 0.00 0 0.00 0
2000 FAIRMAN DRILLING CO 2205 365 0.00 0 0.00 0
2001 FAIRMAN DRILLING CO 1518 365 0.00 0 0.00 0
2002 FAIRMAN DRILLING CO 1349 365 0.00 0 0.00 0
2003 FAIRMAN CORP 2034 365 0.00 0 0.00 0
2010 FAIRMAN CORP 921.00 365 0.00 0 0.00 0
2011 FAIRMAN CORP 815.00 365 0.00 0 0.00 0
2012 FAIRMAN CORP 723.46 365 0.00 0 0.00 0
2013 FAIRMAN CORP 589.09 365 0.00 0 0.00 0
2014 FAIRMAN CORP 511.00 365 0.00 0 0.00 0
2015 FAIRMAN CORP 423.00 334 0.00 0 0.00 0
2016 FAIRMAN CORP 503.00 335 0.00 0 0.00 0
2017 FAIRMAN CORP 316.00 365 0.00 0 0.00 0
2018 FAIRMAN CORP 0.00 0 0.00 0 0.00 0

For data sources see[5]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
1994 FAIRMAN DRILLING CO Brine 70.00 Bbl
1996 FAIRMAN DRILLING CO Brine 75.00 Bbl Brine or Industrial Waste Treatment Plt PA0026310
1997 FAIRMAN DRILLING CO Brine 10.00 Bbl Brine or Industrial Waste Treatment Plt PA0026310
1998 FAIRMAN DRILLING CO Brine 10.00 Bbl Brine or Industrial Waste Treatment Plt 0026310
2002 FAIRMAN DRILLING CO Brine 0.00 Bbl Brine or Industrial Waste Treatment Plt PA0026310
2015 FAIRMAN CORP Produced Fluid 40 Bbl CENT WASTE TRT FAC NPDES PA0101508
2015 FAIRMAN CORP Produced Fluid 40.00 Bbl CENT WASTE TRT FAC NPDES DISCHARGE PA0101508
2017 FAIRMAN CORP Produced Fluid 80.00 Bbl CENT WASTE TRT FAC NPDES DISCHARGE PA0095273

For data sources see[6]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2595842 Primary Facility 2017-05-16 Plugging(Includes Plugged/Mined Through) No Violations Noted Inspection of Fairman’s Carl E Harkleroad #4 conventional gas well in Bell Twp., Clearfield County conducted May 16, 2017 at approximately 10 am. Rig is on location for plugging operations. The rig tagged attainable bottom at ~3040’ (bottom perfs 2988’). Waiting on Allegheny Cementers, job is pushed back due to issue with bulk truck. No issues
2596659 Primary Facility 2017-05-22 Plugging(Includes Plugged/Mined Through) No Violations Noted Inspection of Fairman’s Carl E Harkleroad #4 conventional gas well in Bell Twp., Clearfield County conducted May 22, 2017 at approximately 11:30 am. The plugging rig is off location. The well had surface casing above ground level, no monument installed yet. The casing was full of gravel from top of last plug with some water on top. There were some small bubbles noted at the time of this inspection with minor sporadic bubbling inside the casing where the vent will be installed. No gas was detected at the top of the casing using an Altair 5x gas meter, and no gas detected outside the casing. There were no major issues noted during this inspection, however a future inspection may be necessary to verify.
2604474 Primary Facility 2017-06-13 Plugging(Includes Plugged/Mined Through) No Violations Noted Inspection of Fairman’s Carl E Harkleroad #4 conventional gas well in Bell Twp., Clearfield County conducted June 13, 2017 at approximately 12:00 pm. A rig is spotting in to drill out past cement plug past shoe to run in with camera to troubleshoot cause of bubbling. Suspected source of bubbling is shallow gas show near the shoe. I reviewed the open hole log on location with the operator and discussed the procedure. No major issues.
2614746 Primary Facility 2017-07-07 Plugging(Includes Plugged/Mined Through) No Violations Noted Inspection of Fairman’s Carl E Harkleroad #4 conventional gas well in Bell Twp., Clearfield County conducted July 7, 2017 at approximately 11 am. Rig and crew on location with camera. They ran downhole, bubbles reportedly coming from below the shoe, not at any casing collars. They are planning to pump cmt next week to squeeze channel to fix the issue.
2620562 Primary Facility 2017-07-27 Plugging(Includes Plugged/Mined Through) No Violations Noted Inspection of Fairman’s Carl E Harkleroad #4 conventional gas well in Bell Twp., Clearfield County conducted July 27, 2017 at approximately 10:30 am. Rig and crew on location waiting on bit. I spoke with the crew to discuss plan going forward. The operator intends to drill out 8 5/8” casing past the casing shoe and make another attempt at cement plug(s) in the openhole.
2625973 Primary Facility 2017-08-15 Plugging(Includes Plugged/Mined Through) No Violations Noted Inspection of Fairman’s Carl E Harkleroad #4 conventional gas well in Bell Twp., Clearfield County conducted August 15, 2017 at approximately 1 pm. The well had 8 5/8” x 4” swage with 4” x 2” crossover and open ball valve, visibly venting and audible bubbling at the vent. Cement samples on location looked ok. The operator is attempting to plug is well, shallow gas show near casing shoe is suspected to be causing the issue.
2662422 Primary Facility 2017-11-17 Plugging(Includes Plugged/Mined Through) No Violations Noted Rig on location, in process of rigging down equipment following another plugging attempt. I spoke with the driller, they drilled out past the casing shoe at 766', drilled down to 870' and cemented again. At the time of inspection, the 8 5/8" casing was open. I checked inside the casing with an altair 5x gas meter. Approximately 5% gas was detected. The annulus outside the casing had standing water. There was no bubbling observed. There was no audible bubbling or flow observed inside the casing.
2683732 Primary Facility 2018-01-18 Routine/Complete Inspection No Violations Noted Santo Adamo (production supervisor) of Fairman Corporation reached out to me on January 16, 2018 regarding E&S controls at their recently plugged conventional well Carl E Harkleroad 4 (033-23420). This well was finished being plugged in November 2017. According fo Mr. Adamo, once the weather breaks in the Spring of 2018, the operator will perform final restoration work.

I conducted a site inspection at conventional well 033-23420 on the afternoon of January 18, 2018. The ground was snow covered. Onsite was an E&S plan and PPC Plan. I observed a row of silt fence down gradient of the plugged well (photo 1). I observed a line pit that was snow covered (photo 3). During the time of my inspection, I was unable to determine if any residual waste materials remain present within the lined pit.

I will be conducting another inspection once the snow melts to determine if any further E&S controls are needed.

2687484 Primary Facility 2018-01-25 Plugging(Includes Plugged/Mined Through) No Violations Noted Routine inspection of a well being plugged. Operations have temporarily ceased this winter. At the time of inspection; well is venting through swage, valve, 2" pipe. Gas was present at the vent. I placed my hand over the vent, no significant pressure felt after 30 seconds. No obvious major issues were observed.
2771957 Primary Facility 2018-09-06 Plugging(Includes Plugged/Mined Through) No Violations Noted A routine inspection of this conventional gas well was conducted September 6, 2018. Plugging of this well has been ongoing since last year; venting was observed after initial plugging and there has been an effort to identify the suspect source of gas, drillout, and re-cement thereafter. After further remediation was considered unsuccessful, the operator has vented the well until recently, where they are now rigged up for another attempt to finalize plugging. The suspect source of gas has been determined to be near the 8 5/8" casing shoe. At the time of inspection, a rig is on location. No personnel were on location. There were (4) cement samples on location; (3) of which were slurry samples still transitioning and (1) which is set up. The well itself has 8 5/8" x 4" crossover and 4" x 2" swedge with a valve open to atmosphere. There was no audible or visible venting at the time of inspection. It appears they are WOC after cementing earlier today. No obvious major issues were observed.
2772835 Primary Facility 2018-09-10 Plugging(Includes Plugged/Mined Through) No Violations Noted A routine inspection of this conventional gas well was conducted September 10, 2018. At the time of inspection, there is a rig is on location for for final plug and abandonment. No personnel were on location. The well is open to atmosphere. There was no audible or visible venting at the time of inspection. No gas was detected with an Altair 5x gas meter. No obvious major issues were observed.
2777133 Primary Facility 2018-09-19 Plugging(Includes Plugged/Mined Through) No Violations Noted A routine inspection of this plugged conventional gas well was conducted September 19, 2018. At the time of inspection, the rig and all equipment are off location following most recent of several attempts to plug this well. A 4" vent with marker plate has been made up to 8 5/8" surface casing as a plugged well monument. There was no visible venting. Traces of methane were detected near the mouth of the vent with an Altair 5x gas meter. No obvious major issues were observed during this inspection.
2791853 Primary Facility 2018-10-19 Administrative/File Review No Violations Noted October 19, 2018: Certificate of Plugging for the Carl E. Harkleroad 4 (033-23420) has been received, reviewed, signed, and sent to file.
2804287 Primary Facility 2018-11-16 Routine/Complete Inspection No Violations Noted A routine, post-plugging, inspection of this recently plugged conventional well was conducted November 13, 2018. At the time of inspection, all equipment is off location. A 4 1/2" vent pipe has been installed on 8 5/8" casing as a plugged well monument. The 8 5/8" x 11 3/4" annulus was observed near ground level; no issues were observed. There was standing water outside of the 11 3/4" casing; no bubbling. No obvious issues were observed.
2833637 Primary Facility 2019-01-29 Plugging(Includes Plugged/Mined Through) No Violations Noted A routine, post-plugging, follow-up inspection of this plugged conventional well was conducted January 29, 2019. At the time of inspection, the location was snow covered. There is a 4" vent pipe installed on the surface casing as a plugged well monument. There was snow in the area surrounding the base of the monument, outside of surface and conductor casings. The snow was clean; no evidence of discharge was observed. No evidence of discharge was observed below the mouth of the vent. No open holes, bubbling, visible venting, or other major obvious issues were observed.
371253 Primary Facility 1992-05-01 Routine/Complete Inspection No Violations Noted STREAM WAIVER
371444 Primary Facility 1992-06-23 Routine/Complete Inspection No Violations Noted E&S OK
371455 Primary Facility 1992-07-08 Routine/Complete Inspection No Violations Noted E&S, PITS OK
371685 Primary Facility 1992-08-03 Routine/Complete Inspection No Violations Noted DRILLED; E&S, PITS OK
371891 Primary Facility 1992-06-24 Drilling/Alteration No Violations Noted GRADED; E&S, PITS OK
378224 Primary Facility 1995-05-09 Site Restoration No Violations Noted TANK; E&S OK

For data sources see[7]